If this control is replacing a control that contains mercury in a sealed tube, do not place your old control in the trash.
Contact your local waste management authority for instructions regarding recycling and the proper disposal of an old control containing mercury in a sealed tube.
When Installing this Product…
Electrical Shock or Equipment Damage Hazard.
Can shock individuals or short equipment circuitry.
Disconnect power supply before installation.
Install the thermostat about 5 ft (1.5m) above the floor in an area with good air circulation at an average temperature. Do not install the thermostat where it can be affected by:
Mount the T8775A, C wallplate, with the screws provided. See Fig. 1.
T8775A, C THE DIGITAL ROUND ™
IMPORTANT
Use 18-gauge wire to wire the T8775A, C Thermostats.
All wiring must comply with local electrical codes and ordinances. Disconnect the power supply to prevent electrical shock or equipment damage.
Refer to Fig. 2 through 6 for typical wiring hookups.
Setting Fuel Switch (T8775C only)
The fuel switch is preset at the factory in the F position. See Fig. 7. This is the correct setting for gas or oil systems. If the T8775C is being installed on an electric heat system, or a heat pump, set the switch to the E position. The E setting allows the fan to turn on immediately with the heating equipment in a system where the G terminal is connected.
To adjust the heat cycle rate or the
Fahrenheit/Celsius indication, locate DIP switches 1, 2, and 3 on the back of the thermostat. See Fig. 8.
Set Heat Cycle Rate
Use DIP switches 1 and 2 to set the heat cycle rate.
See Table 1.
Table 1. Heat Cycle Rate.
Heating System | Cycles Per Hour | DIP Switch 1 | DIP Switch 2 |
Steam, Gravity | 1 | On | On |
High-Efficiency Warm Air (90%+ efficiency), Hot Water, Heat Pump | 3 | Off | On |
Gas or Oil Warm Air (factory setting) | 6 | Off | Off |
Electric Warm Air | 9 | On | Off |
In-Floor Radiant Heat | Check with the manufacturer for recommended cycle rate. |
Use DIP switch 3 to set the desired temperature indication. See Table 2.
Table 2. Temperature Indication.
Fahrenheit/Celsius Display | DIP Switch 3 | |
Fahrenheit (factory setting) | Off | |
Celsius | On |
Setting SYSTEM and FAN Switches (T8775C only)
System and fan settings are controlled manually by using the switches located at the top of the thermostat. See Fig. 10.
SYSTEM Switch
Heat: The thermostat controls the heating system.
Off: Both heating and cooling systems are off.
Cool: The thermostat controls the cooling system.
FAN Switch
Auto: The fan only runs with the heating and cooling system.
On: The fan runs continuously. Use for improved air circulation.
NOTE: The temperature setpoint range is 40°F to 90°F (4°C to 32°C) in heating and 45°F to 99°F (7°C to 37°C) in cooling.
Heating
Cooling (T8775C only)
Low-Temperature Hazard.
Operating at too low of an outdoor temperature may cause compressor damage.
Do not operate the cooling if the outdoor temperature is below 50°F (10°C). Refer to the manufacturer’s recommendations.
NOTE: If a call for cooling is made before the compressor has been off for five minutes, or if a power interruption occurs while the compressor is running, the thermostat will go into a five-minute delay to protect the compressor. The snowflake will
Fan
1985 Douglas Drive North, Golden Valley, MN 55422
1-800-468-1502
69-1677EF—03 M.S. Rev. 03-20 | Printed in the United States
© 2020 Resideo Technologies, Inc. All rights reserved.
The Honeywell Home trademark is used under license from Honeywell International, Inc. This product is manufactured by Resideo Technologies, Inc. and its affiliates.
Download Manual:
Honeywell T8775A/C Digital Round Non-Programmable Thermostat Installation Guide
Other manuals:
Honeywell T8775A the Digital Round Non-Programmable Thermostat Owners Manual
Honeywell T8775A the Digital Round Non-Programmable Thermostat Product Data
Honeywell T8775A Digital Round Non-Programmable Thermostat Installation Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…