The T8000C Thermostat provides a single-stage, programmable temperature control for 24 Vac heating-cooling systems with the manual changeover from heat to cool. The heating cycle rate is selectable at 1, 3, 4, 5, 6, 9, or 12 cph. The cooling cycle rate is fixed at 3 cph. Temperature the indication can be set for °F or °C. The T8000C Thermostat is powered through the heating/\ cooling system controls. Batteries are not required because setpoints are held permanently by non-volatile memory. The T8000C model includes a thermostat, wallplate, and owner’s guide. A 7-3/8 in. (188 mm) x 5-3/4 in. (146 mm) decorator cover plate (for covering wall marks) is available separately. Order Honeywell part no. 209649A (taupe) or part no. 209649B (white).
MERCURY NOTICE
If this control is replacing a control that contains mercury in a sealed tube, do not place your old control in the trash. Dispose of it properly. Contact your local waste management authority for instructions regarding recycling and the proper disposal of a control.
When Installing this Product…
CAUTION
Hazardous Voltage. Can damage the heating/cooling system. Disconnect power at the furnace or main breaker/fuse box.
Location
Install the thermostat about 5 ft (1.5m) above the floor in an area with good air circulation at an average temperature. See Fig. 1. Do not install the thermostat where it can be affected by:
Table 1. Description of T8000C Thermostats
Model | System | Changeover | System Selection | Fan Selection | Powering Method |
T8000C | Heat-Cool | Manual | Cool-Off-Heat | Auto-On | Power Stealing |
IMPORTANT
The level is only for appearance. The thermostat functions normally even when not level. Mount the wallplate and the T8000C with the screws provided (see Fig. 2) as follows:
Wiring
IMPORTANT
Use an 18-gauge maximum wire for wiring the T8000C Thermostat.
All wiring must comply with local electrical codes and ordinances. Disconnect the power supply to prevent electrical shock or equipment damage. The shape of the terminals permits the insertion of straight or
wraparound wiring connections; either method is acceptable. A letter code is located near each terminal for identification. See Fig. 3.
NOTE: To ensure proper mounting of the thermostat, restrict all wiring to the shaded area in the center of the terminals. See Fig. 4.
The T8000C Thermostat is powered through the heating/ cooling system controls and is adaptable to most 18 to 3 Vac heating-cooling systems. Refer to Fig. 5, 6, and 7 for typical wiring hookups.
The fan operation (fuel) switch is preset at the factory in the F position. See Fig. 8. This is the correct setting for most systems. If this system is an electric heat system, set the switch to the E position. The E setting allows the fan to turn on immediately with the heating or cooling equipment in a system where the G terminal is connected.
Mounting Thermostat to Wallplate
Installer Setup
Setting °F/°C Indication and Heat Cycle Rate The following instructions provide the information necessary to change the heating cycle rate to match the heating equipment and to choose either Fahrenheit (°F) or Celsius (°C) display.
NOTE: All four steps must be completed to save changes to the °F/°C indication and the heat cycle rate.
Optional System Checkout
When in steps 1c and 1d only, the ▼ key can be pressed to turn the heat or cool outputs on and off. Change the SYSTEM switch set to test heat or cool outputs. No action takes place if the SYSTEM switch is in the Off position.
Examples: System setting at Heat: If heat is on, pressing the ▼ key turns it off; if the heat is off, pressing the ▼ key turns it on. System setting at Cool: If cool is on, pressing the ▼ key turns it off; if cool is off, pressing the ▼ key turns it on. The five-minute minimum off time is bypassed.
NOTE: In Installer Setup only, each press of the ▲ key momentarily displays 1. Each press of the ▼ key momentarily displays 2. When the keys are released, these one-digit codes are no longer displayed
Setting °C or °F.
Setting Heat Cycle Rate (see Table 2 for the cycle rate options and equipment)
Exit Installer Setup
Table 2. Heating Cycle Rate
System | Cycles Per Hour |
Steam, Gravity | 1 |
Hydronic Heat, Condensing Gas Furnacesa | 3 |
Gas or Oil Forced Air | 6 |
Electric Heat | 9 |
Special Applicationsb | 4, 5, 12 |
Setting FAN and SYSTEM Switches
Fan and system settings are controlled manually by using the switches located at the bottom of the thermostat case. See Fig. 10.
FAN Switch
Fan switch settings are:On: The fan runs continuously. Use for improved air circulation and air quality. Auto: Normal setting for most homes. In cooling, the fan starts and stops with the cooling equipment. In heating, the fan is controlled directly by the heating equipment and may start a few minutes after the heating equipment turns on (most systems). When the fan operation (fuel) switch is in the E position, the fan starts and stops with the heating equipment. Slide the FAN switch in the lower-left corner of the thermostat to select the desired fan setting.
SYSTEM Switch
System switch settings control thermostat operation as follows: Cool: The thermostat controls the cooling system. Off: Both heating and cooling are off. Heat: The thermostat controls the heating system. Slide the SYSTEM switch in the lower right corner of the thermostat to select the desired system setting.
To use the preprogrammed time and temperature (see Table 3), press Hold to exit the programming mode.
Setting Time and Temperature
The T8000C is preprogrammed with the time and temperature settings shown in Table 3. For instructions on programming the thermostat refer to the Owners Guide, form no. 69-1143.
Table 3. Preprogrammed Time and Temperature Settings
Period | Time | Heat Setpoint | Cool Setpoint |
Wake | 6:00 AM | 70°F (21°C) | 78°F (26°C) |
Leave | 8:00 AM | 62°F (17°C) | 85°F (29°C) |
CRHetEurCn | KO6U:0T0 PM | 70°F (21°C) | 78°F (27°C) |
Sleep | 10:00 PM | 62°F (17°C) | 82°F (28°C) |
CHECKOUT
Heating
Damage To Compressor Possible. Operating at too low of an outdoor temperature may cause compressor damage. Do not operate the cooling if the outdoor temperature is below 50°F (10°C). Allow the compressor to remain off for five minutes before restarting. Refer to the manufacturer’s recommendations.
Fan
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
Honeywell Limited-Honeywell Limitée
35 Dynamic Drive
Scarborough, Ontario
M1V 4Z9
Download Manual:
Honeywell T8000C Programmable Thermostat Installation Instruction
other manuals:
Honeywell T8000C Programmable Thermostat Owner Guide
Honeywell T8000C Programmable Thermostat Installation Instruction
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…