The Lyric T6/T6R smart thermostats are designed to provide automatic time and temperature control of heating systems in homes and apartments. It’s compatible with 24-230V on/off and OpenTherm® appliances such as gas boilers, combi-boilers and heat pump. Also works with zone valve applications but not with electric heating (240V). The Lyric T6 is for wired on the wall installations and the Lyric T6R for table stand installations (wireless). Both consist of a thermostat and a Receiver box. The solution is designed with the installer in mind and includes a Receiver module with mounting options for directly on the wall or on a wall box. Wiring can be from below or from the back by lifting the terminal platform, which makes installation quick and easy. The thermostat has a high contrast PMVA display with dynamic text line and touch screen buttons. The thermostat has a simple programming philosophy to make it easier to install and very user friendly.. The Lyric T6 is ideal for consumers who want to control their comfort remotely and is based on a modern design, which is simple to program and easy to use.
Reference to the icons
Lyric T6/T6R Thermostat
Control form | : | Adaptive Fuzzy Logic |
Room Temperature display range | : | From 0 oC to 50 oC |
Dimensions (w x h x d) | : | Lyric T6 (wired) 103 x 103 x 28 mm Lyric T6R (wireless) 108 x 103 x 68 mm |
Time display | : | 24-hour or 12-hour AM/PM format |
Timekeeping accuracy | : | Synchronized with the Internet when connected or typically better than 10 minutes per year |
Program | : | 5+2 or daily schedule with 6 daily time and temperature level changes |
Time setting resolution | : | Program – 10-minute steps |
Sensing element | : | 100K (@ 25 oC ) NTC thermistor |
Temperature setting range | : | Program: 5 to 37oC in 0.5 oC steps OFF: 5 oC |
Power | : | Lyric T6 (wired) ~20VDC/300mA by Receiver box Lyric T6R (wireless) 5VDC power adapter |
Wiring | : | Lyric T6 (wired) terminal block capable of accepting wires up to 1.5 mm2 |
RF communication
RF operation band | : ISM (868.0-868.6) MHz, 1% duty cycle |
Max. power | : 25mW |
: | |
Protocol | : Encrypted |
Comm. Range | : 30 m in a residential building environment |
Comm. technology | : short, high-rate transmissions to minimize air time and avoid collisions |
Receiver class R.E.D. | : RX Cat 2 (ETSI EN300 220-1 version 1.3.1) |
RF binding method | : Factory pre-bound |
: | |
Wi-Fi | : IEEE 802.11b/g/n – 2.4GHz |
Max. power | : 10mW |
Receiver box
Power | : 230VAC |
Electrical rating | : 230 V~, 50…60 Hz, 0.5 A to 5 A resistive 0.5 A to 3 A inductive (0.6 pf) 24 V~, 50…60 Hz, 0.5 A to 5 A resistive 0.5 A to 3 A inductive (0.6 pf) |
Cycle rate | : Selectable by application (see installer set up) |
Wiring | : Terminal block capable of accepting wires up to 1.5 mm2 |
Wire access | : From back via large wall box opening. From bottom with cable clamps. Mains wiring – left. Low voltage wiring – right. |
Dimensions | : 110 x 110 x 40 mm (w x h x d) |
IP class | : 30 |
Environmental and standards
Operating temperature range | : | 0 to 40oC |
Shipping and storage temperature | : | -20 to 55oC |
Humidity range | : | 10 to 90% rh, non-condensing |
EMC | : | 2014/30/EU |
LVD | : | 2014/35/EU |
R&TTE: | : | 1995/5/EC |
: | ||
ErP | : | Class V (+3%), (EU) 811/2013 |
Honeywell, declares that this thermostat is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU |
ADVANCED MENU
Specific Applications | Setting | What do you need to change? | ||
Cycle / Hour | Minimu m ON time (in minutes) | Note : a. To change Cycle/Hour, b. To change Minimum ON Time, | ||
Heating | Gas Boilers (<30KW) | 6 | 1 | No action required |
Oil Boiler | 3 | 4 | 1. Set Minimum ON Time to 4 minutes. 2. Set Cycle/Hour to 3. | |
Thermal Actuator | 12 | 1 | Set Cycle/Hour to 12. | |
Zone valve | 6 | 1 | No action is required. |
Special Features | Description |
OpenTherm | If the Receiver box is connected to an OpenTherm appliance various appliance-specific data can be viewed. The data displayed is depending on what the appliance is providing. |
Heat Range | The normal lower temperature limit of 5 oC can be increased up to 21 oC to protect the inhabitants from cold conditions. This is a useful feature aimed at supporting the elderly, children and disabled inhabitants. The normal upper-temperature limit of 35 oC can be reduced down to 21 oC to save energy. This feature is useful for leased homes and apartments. |
Schedule options | The thermostat has 2 default schedules: daily (every day) and 5+2 (week + weekend days) |
External Temperature Sensor (only with wired version) | An external temperature sensor can be fitted, allowing the thermostat to control the temperature from another room or space, where it is inconvenient to locate the thermostat. It will read the remote sensor every 1 minute. The sensor can be connected up to 50 meters from the unit. This feature is useful for commercial premises where the public may tamper with the product. |
Optimisation (optimal start, optimal stop and delayed start) | Optimal Start: learns how long it takes your system to reach the programmed temperature. It turns on the heating system earlier to make sure it’s comfortable at the scheduled time. Optimal Stop: Saves energy and money by switching off a little bit earlier than the normal programmed time. If the home is up to temperature, it will not notice the effect on the temperature, but will show a difference in the fuel bill. Delayed start: Saves energy by slightly delaying the start of heating depending on the difference between the scheduled temperature and the actual room temperature |
Clock setting | Change display format (default 24hr) and adjust time and date. When connected to Internet time and date will be synchronized |
Low Load Control | If the Receiver box is connected to an OpenTherm appliance this setting is used in the demand control. When an appliance is no longer able to modulate lower the control switches from modulating control to low/off control. |
Temperature Offset | If the Thermostat is located in a hot/cold location and cannot be moved because of wiring then the measured/ displayed temperature can be adjusted by +/- 1,5 oC. This feature is useful if the homeowner wants the reading to match another appliance temperature display. |
Binding (only with wireless version) | Menu to bind the Thermostat and the Receiver box, test the RF signal strength of the radio communication and to clear an existing binding. |
Reset | Menu to reset the thermostat back to factory default settings, reset the schedule to default settings, reset the Wi-Fi and Homekit settings. |
Failsafe (only with wireless version) | When the radio communication between the Thermostat and Receiver box is lost for longer than 1 hour the Receiver box will start to cycle the demand 20% on / 80% off. |
Prepare Receiver Box
Needed during installation
Install Receiver Box
Optional cover plate (ACC400)
For mounting on an Italian wall box or in case of a larger foot print of the old thermostat a cover plate can be mounted behind the wall plate. Dimensions 117×117 mm
Install the Lyric T6R wireless thermostat
Complete installation
Turn ON mains power to the Heating Appliance and Receiver Box.
Setup and configuration
After power up, SETUP is displayed on the thermostat’s screen.
BINDING
To bind/rebind
Symptom (Fault message) | Possible Cause | Remedy |
The Receiver box button LED is green but the boiler does not switch on. | Boiler wiring might be incorrect or broken |
Check the Receiver box wiring |
The status LED on the Receiver box is red (Communication loss) | The Receiver box receives no communication from the thermostat: RF communication might be too far or is blocked due to Receiver box location. Thermostat is no longer powered. |
Try to move thermostat or Receiver box closer or re-locate. Check the power to the thermostat |
Thermostat alert messages | ||
WIFI RADIO ERROR | The Wi-Fi radio of thermostat is faulty. | Replace thermostat |
INTERNAL MEMORY ERROR | The internal memory of thermostat is faulty. | Replace thermostat |
INDOOR TEMPERATURE SENSOR ERROR | (wired only) The external temperature sensor is not connected or the wiring is faulty. |
Check external sensor wiring and sensor |
NO COMMUNICATION RECEIVER BOX | The thermostat receives no communication from the thermostat: RF signal is blocked due to the location of the thermostat. Receiver box is no longer powered. | RF communication might be too far or is blocked due to the location of the Thermostat or Receiver box. Check the power to the Receiver box |
RF SIGNAL OFRECEIVER BOX LOW | There is a weak radio signal from the Receiver box | Try to move thermostat or Receiver box closer or re-locate. |
NO RECEIVER BOX | The thermostat is not bound with the Receiver box | Bind or re-bind the Receiver box |
NO INTERNET | Thermostat has no longer Internet connection. | End user needs to check their Internet connection via router. |
NO WIFI SIGNAL | Thermostat has no longer a Wi-Fi connection. | End user needs to check their Wi-Fi network of router. |
REGISTER ONLINE | Thermostat is connected to Internet but not yet registered to an account. | End user needs to download the App, create an account and register the thermostat. |
WIFI NOT CONFIGURED | Thermostat is not connected to a Wi-Fi network. | End user needs to download the App, create an account, connect and register the thermostat. |
BOILER FAILURE FAULT xx | The OpenTherm boiler reported a failure number XX. | Check the boiler |
BOILER LOW WATER PRESSURE | The boiler reported low water pressure. | Fill up the hydronic system with water. |
ORDERING SPECIFICATION
Description | Model | EAN code | Literature |
Smart Thermostat wired Smart Thermostat wired (UK) Smart Thermostat wireless Smart Thermostat Wireless (UK) Large cover plate Lyric T6 | Y6H810WF1005 Y6H910WF1011 Y6H910RW4013 Y6H910RW4022 ACC400 | 5025121381239 5025121381031 5025121381222 5025121381024 5025121381123 | All packaging contains 6 languages: English, Dutch, French, German, Italian and Spanish |
DOWNLOAD MANUAL
Honeywell T6 Lyric Thermostat Product Specifications Guide
Other Manual:
Honeywell T6 Pro Wi-Fi Programmable Thermostat Installation Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…