The T4600 Chronotherm® Electronic Programmable Line Voltage Thermostat provides line voltage control of resistance-rated heating equipment. The patented CoolSwitch™ thyristor commutator design provides long service life. Depending on local climate, night and day setback of space temperature can save up to 23% of the energy used to heat a controlled space. The precise temperature control of the T4600 also provides 12% energy savings during most comfort periods as compared to electromechanical wall thermostats
IMPORTANT
The specifications given in this publication do not include normal manufacturing tolerances. Therefore, this unit might not exactly match the listed specifications. Also, this product is tested and calibrated under closely controlled conditions, and some minor differences in performance can be expected if those conditions are changed.
TRADELINE® Models
TRADELINE® models are selected and packaged to provide ease of stocking, ease of handling, and maximum replacement value.
TRADELINE® Models Available:
T4600A Chronotherm® Electronic Programmable Line Voltage Thermostat with spst switching; makes heating circuit on temperature fall.
When purchasing replacement and modernization products from your TRADELINE® wholesaler or your distributor, refer to the TRADELINE Catalog or price sheets for complete ordering number, or specify:
If you have additional questions, need further information, or would like to comment on our product or services, please write orphone:
In Canada—Honeywell Limited/Honeywell Limiteé, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
When Installing this Product…
WARNING
Equipment Damage Hazard. Improper wiring connections can damage thermostat.
Location
To mount the thermostat, install a vertical outlet box about 5 ft (1.5m) above the floor in an area with good air circulation at room temperature. Do not install the thermostat where it can be affected by:
Wiring and Mounting
Refer to Fig. 2 for typical wiring connections.
Fire Hazard.
Equipment Damage Hazard. Improper wiring connections can cause thermostat damage.
Electrical Shock Hazard.
When the thermostat is first powered or if the battery is drained, the display briefly shows all segments:
Then it shows 00E for 15 seconds followed by a flashing 12:00 AM (midnight) to indicate that the thermostat needs to be programmed. If the time and day program is not entered, the thermostat controls to the default setpoint, 60°F (16°C). If the ambient temperature is below freezing, the display does not operate until the power supply warms up the thermostat to the operating temperature. There will be a clicking from the relay, indicating the thermostat is working even though the display is not restored.
The T4600 is programmed similar to other digital devices:
If no keys are pressed for ten seconds, the T4600 goes to programmed operation and the room temperature is displayed. Automatic operation is activated during programming by holding down the PROG key for four seconds or until the display shows the room temperature
ACTIVITY | RESULT | DISPLAY | |||
SET THE TIME AND DAY Hours: Press and release the PROG key. |
The hour display flashes in the 12-hour (AM/PM) format. |
| |||
Press and release the AUTO key for 24-hour display, if desired. Press the up (+) and down (-) keys to select the correct hour. | Midnight is displayed as 0:00 in 24-hour format. |
Su
PM |
|
| M4655 |
Press and release the PROG key to enter the hour. |
M4789 | ||||
Minutes: Press the up (+) and down (-) keys to select the correct minutes. Press and release the PROG key to enter the minutes. | The minute display flashes. |
Su
PM |
|
|
M4651 |
Day: Press the up (+) and down (-) keys to select the correct day of the week. Press and release the PROG key to enter the day. | The current day flashes along the top of the display. |
Su AM |
Mo
|
|
M4790 |
PROGRAM THE TEMPERATURE SETTINGS Press and release the AUTO key for the Celsius temperature display, if desired.
Comfort Setpoint: Press the up (+) and down (-) keys to select the temperature for desired comfort setpoint. Press and release the PROG key to set the comfort setpoint. |
The display flashes the comfort setpoint. |
NIGHT DAY
M4648 | |||
Economy Setpoint: Press the up (+) and down (-) keys to select the desired economy (setback) setpoint. Press the PROG key to enter the economy temperature. | The display flashes the economy setpoint. |
NIGHT DAY
M4650 |
ACTIVITY | RESULT | DISPLAY |
PROGRAM THE NIGHT SETBACK AND MORNING RECOVERY TIMES Night Setback: Press the up (+) and down (-) keys to select the desired night setback time.
Press and release the PROG key to enter the time. |
The display flashes the NIGHT setback time. The display shows the time in 10-minute increments (eg, 10:10, 10:20, etc). |
PM NIGHT
M4646 |
Morning Recovery: Press the up (+) and down (-) keys to select the desired morning recovery time. Press and release the PROG key to enter the time. | The display flashes the morning recovery (warm-up) time. |
AM
NIGHT
M4647 |
PROGRAM THE DAY SETBACK AND AFTERNOON RECOVERY TIMES Day Setback: Press the up (+) and down (-) keys to select the desired day setback time. |
The display flashes the DAY setback time. |
AM
AUTO MAN TEMPOR NIGHT DAY
M4649 |
Afternoon Recovery: Press the up (+) and down (-) keys to select the desired afternoon recovery time. Press and release the PROG key to enter the time. | The display flashes the afternoon recovery (warm-up) time. |
PM AUTO MAN TEMPOR NIGHT DAY
M4791 |
SELECT PERMANENT HOME (NORMAL) OR SEASONAL RESIDENCE (COTTAGE) OPERATION Press and release the AUTO key to switch between the NORMAL and COTTAGE modes of operation. Using the COTTAGE program overrides the NORMAL program. | ||
Set Normal (5-2) Programs: Press the up (+) and down (-) keys to select the day setback for weekdays or each day of the week. | The display flashes nor5. In the NORMAL program, the setpoint can be set back each day of the week (nor7), weekdays only (nor5), or zero days (nor0). If the setpoint is nor0, night setback is the only active program. |
Su Mo Tu
AUTO MAN TEMPOR NIGHT DAY M4656 |
ACTIVITY | RESULT | DISPLAY |
Set Cottage Programs: CAUTION: Before using the COTTAGE program, make sure there are no water pipes along outside walls, sealed in cabinets or installed in a manner that can cause them to freeze when the room temperature falls to 45°F (7°C).
Press the up (+) and down (-) keys to select the desired COTTAGE program.
Press the up (+) and down (-) keys to select the desired COTTAGE program.
After selecting the NORMAL or COTTAGE program, press and release the PROG key to enter the program. | In the COTTAGE program, the thermostat sets back to 45°F (7°C), which is preprogrammed and not adjustable. The DAY setback program does not operate in the cot0 mode. The temperature is controlled at 45°F (7°C) from the NIGHT setback time on Sunday to the morning recovery time on the following Saturday.
The display flashes cot0, indicating that the day setback program will not operate.
In the cot3 mode, the DAY setback program operates on Friday, Saturday and Sunday. The temperature is controlled at 45°F (7°C) from the NIGHT setback time on Sunday to the afternoon recovery time on the following Friday.
The thermostat enters the programmed mode, displays the room temperature and AUTO. The up arrow indicates the comfort period; the down arrow indicates the economy period. |
AUTO MAN TEMPOR NIGHT DAY
M4659
Su Mo Tu We Th Fr Sa
AUTO MAN TEMPOR NIGHT DAY
M4658
AUTO
M4663 |
TEMPORARILY OVERRIDE THE PROGRAM Press the up (+) and down (-) keys to temporarily change the temperature setpoint. | The current setpoint is displayed on the first press of the up or down key. The setpoint can be changed by pressing the up or down keys again. The display also flashes TEMPOR (temporary). This temporary program override changes back to AUTO operation when the next program change occurs. | AUTO MAN TEMPOR
M4662 |
PERMANENTLY OVERRIDE THE PROGRAM Press and release the AUTO key. | MAN (manual) is displayed. The program change remains in effect until the PROG or AUTO key is pressed. |
AUTO MAN
M4653 |
When the thermostat is first powered or if the battery is drained, the display shows all segments briefly:
Then it shows 00E for 15 seconds followed by a flashing 12:00 AM (midnight) to indicate that the thermostat needs to be programmed. If the time of day program is not entered, the thermostat controls to the default setpoint, 60°F (16°C). If the ambient temperature is below freezing, the display does not operate until the power supply warms up the thermostat to the operating temperature. There will be a clicking from the relay, indicating the thermostat is working even though the display is not restored.
Check out the thermostat operation by simulating normal operation as follows:
Honeywell
Download Manual:
Honeywell T4600 Electronic Programmable Thermostat User Manual
Honeywell T4600 Electronic Programmable Thermostat User Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…