Honeywell T3 Programmable Thermostat USER MANUAL

Honeywell T3 Programmable Thermostat

Thermostat Interface

Screen and Button Overview

  • Programming Menu
  • Settings Menu
  • Alert
  • Room Temperature
  • Current time
  • Heat demand
  • Optimisation
  • Low battery
  • Wireless signal (T3R)
  • Keypad Locked
  • Temperature adjust
  • Right button
  • Middle button
  • Left button
  • Schedule period
  • Day

Status Icons

  • Temperature Override Active: Displayed if the programmed temperature has been manually adjusted.
  • Low Battery: Power has reached approximately 10% (see Changing the Batteries on page 16).
  • Heat Demand: Room temperature is below setpoint – indicating there is a demand for heating (boiler activity might occur).
  • Optimisation Active: Only displayed if optimisation has been enabled in the installer settings.
  • 1 Hour Override Active: Temporary override has been set for one hour.
  • Wireless Signal: Thermostat (T3R only) is connected to the Receiver Box

Navigation Icons

Menu & Navigation Icons

  • MENU Options and settings of your  Thermostat:
    • Heating schedule
    • Settings (Date & Time)
  • Back: Return to the previous screen/menu.
  • Confirm: Confirm a change or selection.
  • Standby: Turns the heating on or off.

Navigating the Menu

  • Press the MENU button to enter the main menu.
  • Press + or buttons to select a menu item – the selected item will flash.
  • Press  confirm the selection.
  • Press+ or- to adjust a setting and then press to save the change and advance to the next selection, or press to go back to previous selection.

Menu

Heating Schedule
Your Thermostat comes with the following default schedule. Follow the next steps to adjust heating schedule.

Adjusting the Schedule

  • Press MENU to enter the main menu
  • Press + or- to select the schedule menu and press
  • Press + or- to select the day to be adjusted and press
  • Press + or- to select the period to be adjusted and press
  • Press + or- to adjust the time and press
  • Press + or- to adjust the temperature and press
  • Repeat these steps to make adjustments to the remaining periods and days – or press to save changes and return to the home screen.

Copy Schedule

  • Press + or- to choose the day you want to copy the schedule from and press COPY
  • Press + or- to choose the day you want to copy the schedule to and press

Delete Period

  • Go to the day and choose the period to delete
  • Press and hold the for 3 seconds and then press
  • Repeat steps 1 and 2 to enable the period again

Settings (Date & Time)

  • Press MENU to enter the main menu
  • Press + or- to select the settings menu SET and press
  • Press to select YEAR (or to skip forward to MONTH
  • Press + or- to adjust the YEAR and press
  • Press to select MONTH (or to skip forward to DAY)
  • Press + or- to adjust the MONTH and press
  • Press to select DAY (or to skip forward to HOUR
  • Press + or- to adjust the DAY and press
  • Press to select HOUR (or to skip forward to MINUTE
  • Press + or- to adjust the HOUR and press
  • Press to select MINUTE and press
  • Press + or- to adjust the MINUTE and press
  • Press to exit SETTINGS and return to the home screen

Device Modes

Automatic Operation
During normal use your Thermostat will follow the programmed schedule – indicated by the icon

Temporary override
Press the + or- set the new desired temperature. The programmed schedule will resume at the next programmed setpoint.

+1hr Timed override
Press for a 1 hour timed override. Press again to cancel

Manual Operation

The set temperature is followed permanently – indicated by the icon.

Permanent override

Press the +or- buttons to adjust the set temperature. This temperature is set until manually changed again.

Standby mode (with frost protect)
Save energy by switching the heating off when not required – e.g. during warmer summer months, or when doors and windows are open for extended periods of time. If the temperature drops to 5°C the heating will come on to prevent the heating pipes freezing.

  • Press to switch the heating off – the display will show OFF
  • Press a gain to switch the heating on – the display will show  or

Keypad Lock

  • Lock
    • Press and hold the Left & Right buttons for 5 seconds. The display will show the icon and (depending on the installer setting) the Thermostat will have limited or no keypad functionality.
  • Unlock
    • When the keypad is locked (indicated by the icon) -Press and hold the Left & Right buttons for 5sec to restore the Thermostat’s full keypad functionality.

Optimization

Optimization
Your Thermostat has optimization functions that aim to save energy while maintaining suitable comfort levels. The Thermostat displays during the optimization period if set. By default optimization is disabled, see instructions on the installation guide on how to activate it.

  • Optimum Start learns how long it takes your home to reach a set temperature and then turns the heating on a bit earlier to achieve that temperature at the programmed time.
  • Delayed Start saves energy by slightly delaying the start of heating depending on the difference between the set temperature and the room temperature.
  • The closer these temperatures are the longer it will delay the start.
  • Optimum Stop saves energy by switching off a little bit earlier than the programmed time. If your home is up to temperature, you will not notice the effect on the temperature, but you should see a difference in your fuel bill.

Changing the Batteries (T3 & T3R only)

  • The Thermostat is powered by 2 x AA batteries, although a battery icon is not shown on the display during normal use.
  • The only time you will see the battery icon is when they get low on power.
  • is displayed when battery power has reached approximately 10% – you should be prepared to change them soon.
  • + will flash when battery power has become critically low – you should change them immediately to make sure there is no disruption to your heating system.
  • Replace with 2 new 1.5V LR6 AA Alkaline batteries only – which should last approximately 2 years depending on Thermostat use

Table Stand a 7 nd Wall Mount (T3R only)

Table Stand

Wall Mount

Wireless Receiver Box (T3R only)
The T3R Thermostat communicates wirelessly to the Receiver Box which is wired to the boiler. If the Thermostat loses wireless communication or becomes faulty, the boiler can be switched on or off manually using the button on the Receiver Box.

  • is displayed on the Thermostat when the wireless signal is good – The receiver box LED will be solid GREEN.
  • + will flash on the Thermostat when the wireless signal is lost – The Receiver Box LED will flash RED.
  • If communication is lost move the Thermostat to another location to try and restore communication.

To manually override the boiler using the Receiver Box:

  • Press the button once to switch the boiler ON or OFF. The button LED should be
    • Solid GREEN when the boiler is ON.
    • Off when the boiler is OFF

Troubleshooting

All models
Screen is blank Replace the batteries (T3 & T3R only).

Check the OpenTherm boiler has power (T3M only). Contact installer.

Thermostat shows Batteries have less than 10% power and need to be replaced soon.
Thermostat shows + Batteries are critically low and need to be replaced immediately – see ‘Changing the Batteries’.
Thermostat shows  but the boiler does not switch on. The boiler cycles on and off as it controls the temperature, and sometimes the  icon will be displayed when the boiler has cycled off.

If the boiler doesn’t switch on after a long period of time contact your installer.

Heating system does not respond to temperature adjust- ments. Make sure the set temperature is higher than the actual room temperature.

Check the heating system is powered on.

Check the Receiver Box is powered and the Thermostat has a wireless signal (T3R only).

Thermostat shows  + – – The temperature sensor of your Thermostat is faulty, contact your installer to repair or replace the Thermostat.
+ SERV Boiler service reminder (UK Only). The boiler is due to be serviced. Please contact your landlord or local housing authority.
T3R (Wireless) Thermostat & Receiver Box only
Thermostat is flashing +  and Receiver Box  LED is flashing RED. Wireless signal lost – Move the Thermostat to another location to try and restore communication.
Thermostat is flashing +  and Receiver Box  LED is off. Check Receiver Box has power by pressing the button to switch boiler on.

If Receiver Box has power then no wireless binding data stored – Follow binding procedure in the installation guide or contact your installer.

Receiver Box  LED is flashing ORANGE. Receiver Box is in binding mode – will time out of this mode after 3 minutes.
T3M (OpenTherm) Thermostat only
An OpenTherm boiler can report alerts back to the Thermostat which can be useful when contacting an installer or maintenance engineer. You can view these in the ‘OpenTherm® boiler alerts’ menu.
Description ID Error code OT Reading
Service request 001 01SR 0 = service not required 1 = service required
Low water pressure 002 02WP 0 = no WP fault 1 = WP fault
Gas/flame fault 003 03GF 0 = no GF fault 1 = GS fault
Air pressure fault 004 04AF 0 = no AP fault 1 = AP fault
Water Over Temperature 005 05WT 0 = no OVT fault 1 = OVT fault
OEM specific 006 06OS Boiler manufacturer specific code

Resideo

  • www.resideo.com
  • ©2019 Resideo Technologies, Inc. All rights reserved.
  • The Honeywell Home trademark is used under license from Honeywell International Inc.

Reference

Download manual:

Honeywell T3 Programmable Thermostat USER MANUAL

Honeywell T3 Programmable Thermostat USER MANUAL

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

2 years ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

2 years ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

2 years ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

2 years ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

2 years ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

2 years ago