ST9100 is an Electronic Timer which provides accurate time control for central heating systems and other applications. ST9100A is a 1-day version and ST9100C is a 7-day version. ST9100 is suitable for replacing a wide range of Timers on the market, and is a direct replacement for Honeywell ST6100 Timers without the need for re-wiring. ST9100 Timers can be combined with other Honeywell controls such as Room Thermostats, Cylinder Thermostats, Wiring Centres and Zone or Diverting Valves to form a fully automatic central heating control system.
If the ST9100 is replacing an existing ST6100 then the existing wall-plate and wiring may be used, subject to any required electrical checks. The Timer should be mounted at a level where the display can be seen clearly, (1.2 to 1.5m from the floor) and the ambient temperature is within the range of 0 to 40°C. The ST9100 is for use in normal domestic environments.
Mounting Options
ALL WIRING MUST BE IN ACCORDANCE WITH I.E.E. REGULATIONS. THIS UNIT IS FOR FIXED WIRING ONLY.
A switch, having contact separation of at least 3mm in all poles (formerly Class ‘A’), must be incorporated in the fixed wiring as a means of disconnecting the supply. The unit is a Class II (double insulated) device. A parking terminal is provided for external earth continuity. The system must be appropriately fused. A fuse rated at no more than 3 Amps should be installed. The unit has 4 knockouts for surface wiring, care must be taken to ensure that the cable or mini-trunking completely fills the knockout hole without leaving any gaps
Final Assembly
ST9100 Internal Wiring
Connections to Combi Boiler
INSTALLER PARAMETER | Parameter Number | LoT™ Display Description | Default Value | Range of Values | Description [LoT™ Display Description] | |
24hr or am/pm clock display | 1 | CLOCK MODE | 12 | 12, 24 | 12 = am/pm display, 24 = 24hr display | [AM-PM] [24 HOUR] |
Configure backlight operation (backlight consumes no additional energy) | 2 | BACKLIGHT | 2 | 0, 1, 2 | 0 = off, 1 = on if button pressed, 2 = on continuously | [NO B-LIGHT] [B-L DELAY] [B-LIGHT ON] |
Enable/disable auto time change | 3 | AUTO TIME | 1 | 0, 1 | 0 = disabled, 1 = enabled | [NO CHANGE] [TIME CHANGE] |
* 1-day or 5/2-day or 7-day operation | 4 | UNIT TYPE | 7 | 1, 5, 7 | 1 = 1-day operation, 5 = 5/2-day operation, 7 = 7-day operation | [1-DAY] [5-2 DAY] [7-DAY] |
Number of ON/OFFs per day | 5 | ON PERIODS | 2 (for ST9100A) 3 (for ST9100C) | 2, 3 | 2 = 2 on/offs per day, 3 = 3 on/offs per day | [2 PER DAY] [3 PER DAY] |
Select default time programme | 6 | DEF PROFILE | A | A, b, C | A = standard, b = at home, C = economy | [PROFILE A] [PROFILE B] [PROFILE C] |
** Reset all parameters | 8 | PROG RESET | 1 | 0, 1 | 0 = do not reset 1 = default parameters | [RESET OFF] [RESET ON] |
Installer Mode
The ST9100 has a special Installer Mode where some features can be adjusted to suit user lifestyle or preferences – these are called installer Parameters, and are listed in the table below, along with a description of the options that are possible
To Enter Installer Mode:
To Exit Installer Mode:
ST6100A, ST6100C | L | N | 1 | 2 | 4 |
* ST9100A, ST9100C | L | N | 1 | 2 | 4 |
* Note: ST6100S1000 should be replaced by ST9100S. If ST9100A or ST9100C are used for replacing ST6100S, please refer to Honeywell for wiring details. The Service Timeout feature will not be available in this case, and wiring may have to change, depending on the application. | |||||
ST7000B | L | – | – | 2 | 3 |
** ST9100 | L | N | 1 Link to terminal L | 2 | 4 |
** Note: A permanent mains supply must be provided for the ST9100 Timer. |
Replacing Other Manufacturers’ Time Controls
ST9100 Timers will mount directly onto many existing manufacturers’ back-plates, without the need for re-wiring. However, they are also supplied complete with a wiring back-plate, should this not be the case. Refer to Honeywell for wiring conversion diagrams. (see Wiring Guide document EN3H 2393 UK01
This product and its associated documentation and packaging are protected by various intellectual property rights belonging to Honeywell Inc and its subsidiaries and existing under the laws of the UK and other countries. These intellectual and property rights may include patent applications, registered designs, unregistered designs, registered trade marks, unregistered trade marks and copyrights. Honeywell reserves the right to modify this document, product and functionality without notice. This document replaces any previously issued instructions and is only applicable to the product(s) described. This product has been designed for applications as described within this document. For use outside of the scope as described herein, refer to Honeywell for guidance. Honeywell cannot be held responsible for misapplication of the product(s) described within this document. Manufactured for and on behalf of the Environment and Combustion Controls Division of Honeywell Technologies Sarl, Ecublens, Route du Bois 37, Switzerland by its Authorised Representative Honeywell Inc
Honeywell
DOWNLOAD MANUAL
Honeywell ST9100A Electronic Thermostat INSTALLATION INSTRUCTIONS
Honeywell ST9100A Electronic Thermostat INSTALLATION INSTRUCTIONS
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…