Introduction

ST9100 is an Electronic Timer which provides accurate time control for central heating systems and other applications. ST9100A is a 1-day version and ST9100C is a 7-day version. ST9100 is suitable for replacing a wide range of Timers on the market, and is a direct replacement for Honeywell ST6100 Timers without the need for re-wiring. ST9100 Timers can be combined with other Honeywell controls such as Room Thermostats, Cylinder Thermostats, Wiring Centres and Zone or Diverting Valves to form a fully automatic central heating control system.

Specification

  • Power Supply: 230V~, 50…60Hz, 10W
  • Switch Action: 1 x SPDT, potential free
  • Switch Rating: 230V~, 50…60Hz, 3(3)A max, 10mA at 12 Vdc minimum
  • Factory set clock
  • Power Reserve: lifetime battery
  • Programmes/Settings: permanently stored in NV RAM
  • Approvals: Conforms to protection requirements of
  • Directives 2006/95EC and 89/336EC

Mounting

If the ST9100 is replacing an existing ST6100 then the existing wall-plate and wiring may be used, subject to any required electrical checks. The Timer should be mounted at a level where the display can be seen clearly, (1.2 to 1.5m from the floor) and the ambient temperature is within the range of 0 to 40°C. The ST9100 is for use in normal domestic environments.Honeywell- ST9100A- Electronic- Thermostat- 1

Mounting OptionsHoneywell- ST9100A- Electronic- Thermostat- 3

WiringHoneywell- ST9100A- Electronic- Thermostat- 2

ALL WIRING MUST BE IN ACCORDANCE WITH I.E.E. REGULATIONS. THIS UNIT IS FOR FIXED WIRING ONLY.
A switch, having contact separation of at least 3mm in all poles (formerly Class ‘A’), must be incorporated in the fixed wiring as a means of disconnecting the supply. The unit is a Class II (double insulated) device. A parking terminal is provided for external earth continuity. The system must be appropriately fused. A fuse rated at no more than 3 Amps should be installed. The unit has 4 knockouts for surface wiring, care must be taken to ensure that the cable or mini-trunking completely fills the knockout hole without leaving any gaps

Final Assembly

  • Clip the unit onto the hinges on the top of the wallplate and hinge down into position. Tighten the two securing screws using a screwdriver.
  • Switch on the power – the unit will now be operating according to the built-in programme. Note : the ST9100 is supplied with a factory set clock for faster installation .
  • Refer to ST9100 User Guides for programming details

Honeywell- ST9100A- Electronic- Thermostat- 4WIRING CONNECTIONS

ST9100 Internal WiringHoneywell- ST9100A- Electronic- Thermostat- 5

Connections to Combi BoilerHoneywell- ST9100A- Electronic- Thermostat- 6

ADDITIONAL PRODUCT FEATURES

INSTALLER PARAMETER Parameter Number LoT™ Display Description Default Value Range of Values Description [LoT™ Display Description]
24hr or am/pm clock display 1 CLOCK MODE 12 12, 24 12 = am/pm display, 24 = 24hr display [AM-PM] [24 HOUR]
Configure backlight operation (backlight consumes no additional energy) 2 BACKLIGHT 2 0, 1, 2 0 = off,

1 = on if button pressed, 2 = on continuously

[NO B-LIGHT] [B-L DELAY] [B-LIGHT ON]
Enable/disable auto time change 3 AUTO TIME 1 0, 1 0 = disabled,

1 = enabled

[NO CHANGE] [TIME CHANGE]
* 1-day or 5/2-day or 7-day operation 4 UNIT TYPE 7 1, 5, 7 1 = 1-day operation,

5 = 5/2-day operation, 7 = 7-day operation

[1-DAY]

[5-2 DAY]

[7-DAY]

Number of ON/OFFs per day 5 ON PERIODS 2  (for ST9100A)

3  (for ST9100C)

2, 3 2 = 2 on/offs per day,

3 = 3 on/offs per day

[2 PER DAY]

[3 PER DAY]

Select default time programme 6 DEF PROFILE A A, b, C A = standard, b = at home, C = economy [PROFILE A] [PROFILE B] [PROFILE C]
** Reset all parameters 8 PROG RESET 1 0, 1 0 = do not reset

1 = default parameters

[RESET OFF] [RESET ON]

Installer Mode
The ST9100 has a special Installer Mode where some features can be adjusted to suit user lifestyle or preferences – these are called installer Parameters, and are listed in the table below, along with a description of the options that are possible

To Enter Installer Mode:

  • a. Ensure the slider is in the RUN position, then press and hold the Honeywell- ST9100A- Electronic- Thermostat- 7buttons together for 8 seconds. Ignore the ‘NOT VALID’ that is displayed for a few seconds. The message ‘SET UP MENU’ will show briefly, followed by ‘SET INSTALLER OK ?’
  • b. Press theHoneywell- ST9100A- Electronic- Thermostat- 8 button to take you into the Installer Mode Parameter Menu.
  • c. Parameter 1 is now available to change. This is to allow you to change the clock format from 12 hour AM/PM to 24 hour. At every step, the LoT™ Display will inform you what the parameter means and what option you have selected. The parameter number is shown on the display separated by a colon from the parameter value.
  • d. You can change the parameter value by pressing the Honeywell- ST9100A- Electronic- Thermostat- 7buttons. At this point, the description in the LoT™ Display will change and the parameter value will flash. If you press Honeywell- ST9100A- Electronic- Thermostat- 8the value will stop flashing and will be saved for use.
    e. Press to move to the next parameter available for editing. The parameter number will change accordingly.
  • f. Keep pressing Honeywell- ST9100A- Electronic- Thermostat- 8to step around the list of parameters, and use Honeywell- ST9100A- Electronic- Thermostat- 7buttons to change the parameter value.
    g. Any parameter changes that have been confirmed with the Honeywell- ST9100A- Electronic- Thermostat- 8button will be saved and used.Honeywell- ST9100A- Electronic- Thermostat- 6

To Exit Installer Mode:

  • You can exit Installer Mode at any time by moving the slider to the next position and then back again to RUN.
  • Note: Installer Mode will exit automatically after 10 minutes if the slider is not moved.

Replacement Wiring

ST6100A, ST6100C L N 1 2 4
* ST9100A, ST9100C L N 1 2 4
* Note: ST6100S1000 should be replaced by ST9100S.

If ST9100A or ST9100C are used for replacing ST6100S, please refer to Honeywell for wiring details.

The Service Timeout feature will not be available in this case, and wiring may have to change, depending on the application.

ST7000B L 2 3
** ST9100 L N 1 Link to terminal L 2 4
** Note: A permanent mains supply must be provided for the ST9100 Timer.

Replacing Other Manufacturers’ Time Controls

ST9100 Timers will mount directly onto many existing manufacturers’ back-plates, without the need for re-wiring. However, they are also supplied complete with a wiring back-plate, should this not be the case. Refer to Honeywell for wiring conversion diagrams. (see Wiring Guide document EN3H 2393 UK01

Completion Checklist for Installation

  1. Check unit powers up correctly, and that the display does not remain
  2. Set operating mode to AUTO and switch on and off using the OVERRIDE button, to ensure the system is operating
  3. Check the factory-set day, date, and time are correct and adjust if Refer to the User Guide for details.
  4. If required, enter Installer Mode and adjust Installer Parameters to match the lifestyle and needs of the User. Remember to make a note of these parameter changes in the Configuration Data section of the User Guide.
  5. Explain the operation of the product to the User and help them to set their programme. There are 3 built-in profiles that can be used as a basis for a typical User programme.
  6. If required, attach the self-adhesive programme guide label to the underside of the cover flap. The label is supplied in the box and requires to be peeled away from the backing material before use.
  7. Explain when the User should contact someone to arrange a Service
  8. Write the date of installation, your name and telephone number in the space provided in the User Guide, in the section ‘Boiler & System Service Log’
  9. Remember to leave the User Guide and Installation Instructions with the User and remind them to keep them in a safe This forms part of a Home Information Pack.

This product and its associated documentation and packaging are protected by various intellectual property rights belonging to Honeywell Inc and its subsidiaries and existing under the laws of the UK and other countries. These intellectual and property rights may include patent applications, registered designs, unregistered designs, registered trade marks, unregistered trade marks and copyrights. Honeywell reserves the right to modify this document, product and functionality without notice. This document replaces any previously issued instructions and is only applicable to the product(s) described. This product has been designed for applications as described within this document. For use outside of the scope as described herein, refer to Honeywell for guidance. Honeywell cannot be held responsible for misapplication of the product(s) described within this document. Manufactured for and on behalf of the Environment and Combustion Controls Division of Honeywell Technologies Sarl, Ecublens, Route du Bois 37, Switzerland by its Authorised Representative Honeywell Inc

Honeywell

  • Honeywell Control Systems Ltd.
  • Arlington Business Park,
  • Bracknell
  • Berkshire
  • RG12 1EB
  • Technical Help Desk: 08457 678999
  • www.honeywelluk.com

REFERENCE

DOWNLOAD MANUAL

Honeywell ST9100A Electronic Thermostat INSTALLATION INSTRUCTIONS

Honeywell logo

Honeywell ST9100A Electronic Thermostat INSTALLATION INSTRUCTIONS

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *