The DT92 wireless room thermostat comprises a DT92 Room Thermostat and a BDR91 Relay Box. These devices communicate on an 868MHz Radio Frequency (RF) band to control a single heating system component such as a boiler, pump or zone valve. RF communication is 2-way, allowing high performance energy efficient control, display of boiler information, and easy setup and communications check features.
Installation Notes
Power up
RF Communication Test
Locating the Room Thermostat
For best performance, install in an open space where DT92 can sense the room temperature, and where the signal strength is high. The Room Thermostat can be mounted on a wall or on the optional table stand. Leave at least 30cm distance from any metal objects and at least 1 metre from any other electrical equipment. Select the preferred location and test the Signal Strength before installation
Signal Strength Test
Mounting the Room Thermostat
Test & Binding Flow-chart
Automatic Operation
Temporary Manual Override
Loss of RF communications
To enter Installer Mode
To select a parameter
Display
To change a parameter
To exit Installer Mode
Parameter flowchart
Parameters
Description | Parameter | Range of values | Default |
Minimum ON/OFF time Tempo minimo accesso | OT | 1,2,3,4,5 m | 1 m |
Cycle rate | Cr | {3,6,9,12} | 6 |
Proportional bandwidth | Pb | 1.5 … 3.0 K | 1.5K |
Description | Parameter | Range of values | Default |
Temperature measurement offset | tO | -3 … 3 K | 0 K |
temperature | |||
Temperatur-Offset | |||
Upper setpoint limit | uL | 21 … 35 °C | 35°C |
consigne maximale | |||
Limite superiore della temperatura | |||
teplota | |||
Lower setpoint limit | LL | 5 … 21 °C | 5°C |
limite de consigne minimale | |||
Temperatursollwertgrenze | |||
lapel korlát | |||
Najnižšia nameraná teplota | |||
ECO temperature | ES | 5 … 35 °C | 18 °C |
temperatuursinstelling | |||
ECO deploy | |||
Heat/cool changeover | HC | 0 / 1 | 0 |
warmen/koelen Cambiamento Off setpoint adjust Room temperature sensor use Failsafe mode (loss of RF communications) Enable HR80 window-open function Enable HR80 local override Reset parameters | OS SuLC HO HL | 0 = Disable / 1 = Enable– (= Off), 5…16°C 0 = DT92 sensor | 0 = DT92 0 = Off 1 (factory) |
The binding operation shown is required if:
Reset stored data in Relay Box
Put Relay Box into Binding Mode
Reset stored data in Room Thermostat
Put Room Thermostat into Binding Mode
Bind Room Thermostat to Relay Box
Now go to Section 3.2 RF Communication Test
Manufactured
Manufactured for and on behalf of the Environment and Combustion Controls Division of Honeywell Technologies Sàrl, ACS-ECC EMEA, Z.A. La Pièce 16, 1180 Rolle, Switzerland, by its Authorised Representative Honeywell Inc.
Download Manual:
Honeywell DT92E Wireless Room Thermostat Installation Manual
OTHER MANUALS:
Honeywell DT92E Wireless Room Thermostat User Guide
Honeywell DT92E Wireless Room Thermostat Installation Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…