Advanced options can be classified in two sets.
MODE 1:Turn off the thermostat. Press SET for 3 seconds.It will display A01-A09.
Then press SET to switch between these options.
Display symbol | Option content | Press “+” or “-” to adjust value |
20. oC 5 Ro6 | Temperature compensation (A01) | Press “+” or “ -” key to adjust setting value (0 ~ F F) increment: 0.5oC |
1.0 AO2 | Start differential temperature (A02) | Range: 1°C~5°C: 1. When the setting temperature is higher than or equal to the sum of the indoor temperature and the start differential temperature, the heating equipment will turn on. 2. When the indoor temperature is higher than or equal to the sum of the setting temperature and the start differential temperature, the heating equipment will turn off. |
0 AO3 | Keypad (A03) | 0 half locked: all keys are locked except for the on-off key; 1 full locked, all keys are locked including the on-off key. |
45oC Ro4 | High Temp Protection (A04 | ) Range: 35~70 When the lowest setting temperature is 35°C, press “-”, it will display “- -”, high temperature protection function is cancelled; if the indoor temperature is higher than the high temperature protection value, the heating equipment will be cut off. Default value is = 45°C |
5oC Ro5 | Low Temp Protection (A05 | Range: 5°C~10°C. When the highest setting temperature is 10°C, press “+” it wil) display “- -”, the low-temperature protection function is cancelled; if the indoor temperature is lower than the low-temperature protection value, the heating equipment will turn on. Default value is = 5°C |
5oC Ro6 | Setting Temp Lowest Limiting Value (A06) | Range: 1°C~10°C: |
35oC Ro7 | Setting Temp Highest Limiting Value (A07) | Range: 30°C~70°C |
MON TUE WED THU FRI | Week | MON TUE WED THU FRI SAT SUN represent 7-days programme |
Ro8 | Programme | MON TUE WED THU FRI SAT represents 6 + 1 programme |
Choice (A08) | MON TUE WED THU FRI represent 5 + 2 programme | |
“- -” represent programme is cancelled | ||
55 0001 | Transceiver IP Check (A09) | Within 10 seconds after the transceiver powers on, press “+” key shortly, check the transceiver. Check successfully as shown. |
MODE 2:
Turn off the thermostat, and long press “PRO” for 3 seconds it will display B01-B08, then press “SET” to switch between these options
Display symbol | Option content | Press “+” or “-” to adjust value |
1.0 601 | Version number (b01) | Version number 1.0 |
00H 602 | IP high Setting (b02) | Press “+” or “ -” key to adjust setting value (0 ~ F F) |
01 l 603 | IP low setting (b03) | Press “+” or “ -” key to adjust setting value (1 ~ F F) |
55 6o4 | Write transceiver IP address (b04) | Within 10 seconds after the transceiver power on, press the “+” key to send the address |
1 6o5 | Valve controlling selection (b05) | Press “+” or “-” keys to adjust the setting value, The 0 valve is controlled by a thermostat, 1 valve is not controlled by a thermostat, and the Keep valve in the closed state |
1 6o6 | Descaling function (b06) | Press the “+” or “-” key to adjust the setting value, 0 turn off, 1 turn on Descaling function: continue to close the valve for 100 hours and forced to open the valve for 3 minutes |
1F 6o7 | Degrees Celsius and Fahrenheit selection (b07) | Press “+” or “-” key to adjust setting value, 0 turn off, 1 turn on Descaling function: continue to close valve for 100 hours and force to open the valve for 3 minutes |
RO 6o8 | Factory reset (b08) | Display Ao, long press PRG key, show all setting key and factory reset |
OPERATION KEY | ||
NO | KEY | DESCRIPTION |
A | SET | Set key: short press to switch programme mode to manual mode. In programme mode, press “+ ” or “ -” to adjust the value. It will automatically enter into temporary manual mode. |
B | + | Increasing key. |
C | PRG | Clock key: short press to set the clock, long press to set programme. Keys locked/unlocked:press and at the same time for 3 seconds. |
D | Decreasing key. | |
E | Power | Power on/off key. |
Interval | Monday to Friday | The default value | Saturday and Sunday | The default value | |
1st | 06:00-08:00 | 20°C | 06:00-08:00 | 20°C | |
2nd | 08:00-11:30 | 15°C | 08:00-11:30 | 15°C | |
3rd | 11:30-13:30 | 15°C | 11:30-13:30 | 15°C | |
4th | 13:30-17:00 | 15°C | 13:30-17:00 | 15°C | |
5th | 17:00-22:00 | 22°C | 17:00-22:00 | 22°C | |
6th | 22:00-06:00 | 15°C | 22:00-06:00 | 15°C |
SENDING CONDITION OF THERMOSTAT
Transceiver LED display indication:
ADVANCED OPTIONS
Advanced options can be classified in two sets
MODE 1: Turn off the thermostat. , Press for 3 seconds. It will display A01-A09,
Then press to switch between these options.
Download Manual
Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…
Honeywell Prestige THX9000 Touch-screen Thermostat About your new thermostat Your new thermostat is pre-programmed and…