Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

HETTA-LOGO

Hetta HS01RF WIRELESS THERMOSTAT Kit

Hetta-HS01RF-WIRELESS- THERMOSTAT-KIT-PRODUCT

PAIRING INSTRUCTIONS

  1. Insert batteries into the Thermostat.
  2. Ensure that the receiver has a 230v supply and that the NTC probe is wired in.
  3. Locate the IP number within the Receiver and on the rear of the Thermostat, for example, IP181013 084F.
  4. Turn the Thermostat OFF.
  5. Press and hold the PRG button for 3 seconds, until b01 is showing.
  6. Using the SET button, toggle to b02 to enter the 1st two digits of the IP number with the + and – buttons.
    In the example above, it would be 18.
  7. Press the SET button and toggle to b03 and enter the last two digits of the IP number (4F, in the example above).
  8. Press the SET button and toggle to b04, at this time slide the switch on the receiver to show the green and orange light, within 10 seconds of sliding the switch press the + button on the stat and 00 will change to a new value.
  9. Press the power button to return to the home screen.
  10. To test, use the + and – buttons and increase the SET TEMP to at least 2 degrees above the ROOM TEMP, the heating on symbol should be displayed and shortly after the zone valve/pump will operate.

ADVANCED OPTIONS

Advanced options can be classified in two sets.
MODE 1:Turn off the thermostat. Press SET for 3 seconds.It will display A01-A09.
Then press SET to switch between these options.

Display symbol Option content Press “+” or “-” to adjust value
20. oC
5
Ro6
Temperature compensation

(A01)

Press “+” or “ -” key to adjust setting value (0 ~ F F) increment: 0.5oC
1.0
AO2
Start differential temperature (A02) Range: 1°C~5°C:

1.  When the setting temperature is higher than or equal to the sum of the indoor temperature and the start differential temperature, the heating equipment will turn on.

2.  When the indoor temperature is higher than or equal to the sum of the setting temperature and the start differential temperature, the heating equipment will turn off.

0
AO3
Keypad (A03) 0 half locked: all keys are locked except for the on-off key; 1 full locked, all keys are locked including the on-off key.
45oC

Ro4

High Temp Protection (A04 ) Range: 35~70 When the lowest setting temperature is 35°C, press “-”, it will display “- -”, high temperature protection function is cancelled; if the indoor temperature is

higher than the high temperature protection value, the heating equipment will be cut off. Default value is = 45°C

5oC

Ro5

Low Temp Protection (A05 Range: 5°C~10°C. When the highest setting temperature is 10°C, press “+” it wil) display “- -”, the low-temperature protection function is cancelled; if the indoor temperature is lower than the low-temperature protection value, the heating equipment will turn on. Default value is = 5°C
5oC

Ro6

Setting Temp Lowest Limiting Value (A06) Range: 1°C~10°C:
35oC

Ro7

Setting Temp Highest Limiting Value (A07) Range: 30°C~70°C
MON TUE WED THU FRI Week MON TUE WED THU FRI SAT SUN represent 7-days programme
Ro8 Programme MON TUE WED THU FRI SAT represents 6 + 1 programme
Choice (A08) MON TUE WED THU FRI represent 5 + 2 programme
“- -” represent programme is cancelled
55
0001
Transceiver IP Check (A09) Within 10 seconds after the transceiver powers on, press “+” key shortly, check the transceiver. Check successfully as shown.

MODE 2:
Turn off the thermostat, and long press “PRO” for 3 seconds it will display B01-B08, then press “SET” to switch between these options

Display symbol Option content Press “+” or “-” to adjust value
1.0

601

Version number (b01) Version number 1.0
00H

602

IP high Setting (b02) Press “+” or “ -” key to adjust setting value (0 ~ F F)
01 l

603

IP low setting (b03) Press “+” or “ -” key to adjust setting value (1 ~ F F)
55

6o4

Write transceiver IP address (b04) Within 10 seconds after the transceiver power on, press the “+” key to send the address
1

6o5

Valve controlling selection (b05) Press “+” or “-” keys to adjust the setting value, The 0 valve is controlled by a thermostat, 1 valve is not controlled by a thermostat, and the Keep valve in the closed state
1

6o6

Descaling function (b06) Press the “+” or “-” key to adjust the setting value, 0 turn off, 1 turn on Descaling function: continue to close the valve for 100 hours and forced to open the valve for 3 minutes
1F

6o7

Degrees Celsius and Fahrenheit selection (b07) Press “+” or “-” key to adjust setting value, 0 turn off, 1 turn on Descaling function: continue to close valve for 100 hours and force to open the valve for 3 minutes
RO

6o8

Factory reset (b08) Display Ao, long press PRG key, show all setting key and factory reset

Hetta-HS01RF-WIRELESS- THERMOSTAT-KIT-FIG.1

PRODUCT SPECIFIC

  • Power: Two AA* 1.5V alkaline batteries
  • Range of temperature display: 0~40°C/32~104°F
  • Insulating condition: Normal environment
  • Running programme: Set per 1 week as a cycle
  • Installation: Wall mounted or on battery seat
  • Working environment temperature: 0~70°C/32~122°F
  • Range of temperature adjustment: 5~35°C/41~95°F
  • Display accuracy: 0.5°C or 1°F
  • Output: Switch relay
  • Probe sensor: NTC(10k)1%
  • Size(mm): 130*90*27 and 107*78*28
  • Contact capacity: 16A/220V(RF electric heating)
    5A/220V(RF gas boiler heating)
    3A/220V(RF water heating)

DISPLAYS & BUTTONS

Hetta-HS01RF-WIRELESS- THERMOSTAT-KIT-FIG.2

OPERATION KEY
NO KEY DESCRIPTION
A SET Set key: short press to switch programme mode to manual mode. In programme mode, press “+ ” or “ -” to adjust the value. It will automatically enter into temporary manual mode.
B + Increasing key.
C PRG Clock key: short press to set the clock, long press to set programme. Keys locked/unlocked:press and  at the same time for 3 seconds.
D    Decreasing key.
E Power Power on/off key.

RUN MODE Factory Preset Mode

Interval Monday to Friday The default value Saturday and Sunday The default value  

Hetta-HS01RF-WIRELESS- THERMOSTAT-KIT-FIG.3

1st 06:00-08:00 20°C 06:00-08:00 20°C
2nd 08:00-11:30 15°C 08:00-11:30 15°C
3rd 11:30-13:30 15°C 11:30-13:30 15°C
4th 13:30-17:00 15°C 13:30-17:00 15°C
5th 17:00-22:00 22°C 17:00-22:00 22°C
6th 22:00-06:00 15°C 22:00-06:00 15°C

SENDING CONDITION OF THERMOSTAT

  • Send once every 20 minutes
  • Press on/off key
  • Switch over output state
  • Communication instruction, be long bright display in normal communication and blinking display in abnormal communication

TRANSCEIVER TIPS

Transceiver LED display indication:

  • Power light (green light): bright when power is on.
  • Signal light (orange light): long bright light within 10s after power on (match IP), signal light off when it
  • Receives match, signal light blinks within 10 seconds when power off.
  • Load light/fault light (red light):
    • A. When no fault: light on when load output, lights off when no load output.
    • B. When fault: light is blinking indicating a fault.
  • The signal light blinks once when it does not receive 485 signals for 1 hour (light on 0.25 seconds light off 0.25 seconds), spacing out the light for 2 seconds.
  • IP fault (IP: F), the light blinks twice (light on 0.25 seconds light o ff 0.25 seconds), spacing out the light for 2 seconds.
  • Light blinks 3 times when it does not receive a wireless signal for 1 hour (light on 0.25 seconds light off 0.25 seconds), spacing out the light for 2 seconds.
  • The light blinks 4 times when the built-out sensor is faulty (light on 0.25 seconds light off 0.25 seconds), spacing out the light for 2 seconds..

ADVANCED OPTIONS

Advanced options can be classified in two sets

MODE 1: Turn off the thermostat. , Press for 3 seconds. It will display A01-A09,
Then press to switch between these options.

WIRING DIAGRAM

Hetta-HS01RF-WIRELESS- THERMOSTAT-KIT-FIG.4