Hetta HS01RF WIRELESS THERMOSTAT Kit
PAIRING INSTRUCTIONS
- Insert batteries into the Thermostat.
- Ensure that the receiver has a 230v supply and that the NTC probe is wired in.
- Locate the IP number within the Receiver and on the rear of the Thermostat, for example, IP181013 084F.
- Turn the Thermostat OFF.
- Press and hold the PRG button for 3 seconds, until b01 is showing.
- Using the SET button, toggle to b02 to enter the 1st two digits of the IP number with the + and – buttons.
In the example above, it would be 18. - Press the SET button and toggle to b03 and enter the last two digits of the IP number (4F, in the example above).
- Press the SET button and toggle to b04, at this time slide the switch on the receiver to show the green and orange light, within 10 seconds of sliding the switch press the + button on the stat and 00 will change to a new value.
- Press the power button to return to the home screen.
- To test, use the + and – buttons and increase the SET TEMP to at least 2 degrees above the ROOM TEMP, the heating on symbol should be displayed and shortly after the zone valve/pump will operate.
ADVANCED OPTIONS
Advanced options can be classified in two sets.
MODE 1:Turn off the thermostat. Press SET for 3 seconds.It will display A01-A09.
Then press SET to switch between these options.
Display symbol | Option content | Press “+” or “-” to adjust value |
20. oC 5 Ro6 |
Temperature compensation
(A01) |
Press “+” or “ -” key to adjust setting value (0 ~ F F) increment: 0.5oC |
1.0 AO2 |
Start differential temperature (A02) | Range: 1°C~5°C:
1. When the setting temperature is higher than or equal to the sum of the indoor temperature and the start differential temperature, the heating equipment will turn on. 2. When the indoor temperature is higher than or equal to the sum of the setting temperature and the start differential temperature, the heating equipment will turn off. |
0 AO3 |
Keypad (A03) | 0 half locked: all keys are locked except for the on-off key; 1 full locked, all keys are locked including the on-off key. |
45oC
Ro4 |
High Temp Protection (A04 | ) Range: 35~70 When the lowest setting temperature is 35°C, press “-”, it will display “- -”, high temperature protection function is cancelled; if the indoor temperature is
higher than the high temperature protection value, the heating equipment will be cut off. Default value is = 45°C |
5oC
Ro5 |
Low Temp Protection (A05 | Range: 5°C~10°C. When the highest setting temperature is 10°C, press “+” it wil) display “- -”, the low-temperature protection function is cancelled; if the indoor temperature is lower than the low-temperature protection value, the heating equipment will turn on. Default value is = 5°C |
5oC
Ro6 |
Setting Temp Lowest Limiting Value (A06) | Range: 1°C~10°C: |
35oC
Ro7 |
Setting Temp Highest Limiting Value (A07) | Range: 30°C~70°C |
MON TUE WED THU FRI | Week | MON TUE WED THU FRI SAT SUN represent 7-days programme |
Ro8 | Programme | MON TUE WED THU FRI SAT represents 6 + 1 programme |
Choice (A08) | MON TUE WED THU FRI represent 5 + 2 programme | |
“- -” represent programme is cancelled | ||
55 0001 |
Transceiver IP Check (A09) | Within 10 seconds after the transceiver powers on, press “+” key shortly, check the transceiver. Check successfully as shown. |
MODE 2:
Turn off the thermostat, and long press “PRO” for 3 seconds it will display B01-B08, then press “SET” to switch between these options
Display symbol | Option content | Press “+” or “-” to adjust value |
1.0
601 |
Version number (b01) | Version number 1.0 |
00H
602 |
IP high Setting (b02) | Press “+” or “ -” key to adjust setting value (0 ~ F F) |
01 l
603 |
IP low setting (b03) | Press “+” or “ -” key to adjust setting value (1 ~ F F) |
55
6o4 |
Write transceiver IP address (b04) | Within 10 seconds after the transceiver power on, press the “+” key to send the address |
1
6o5 |
Valve controlling selection (b05) | Press “+” or “-” keys to adjust the setting value, The 0 valve is controlled by a thermostat, 1 valve is not controlled by a thermostat, and the Keep valve in the closed state |
1
6o6 |
Descaling function (b06) | Press the “+” or “-” key to adjust the setting value, 0 turn off, 1 turn on Descaling function: continue to close the valve for 100 hours and forced to open the valve for 3 minutes |
1F
6o7 |
Degrees Celsius and Fahrenheit selection (b07) | Press “+” or “-” key to adjust setting value, 0 turn off, 1 turn on Descaling function: continue to close valve for 100 hours and force to open the valve for 3 minutes |
RO
6o8 |
Factory reset (b08) | Display Ao, long press PRG key, show all setting key and factory reset |
PRODUCT SPECIFIC
- Power: Two AA* 1.5V alkaline batteries
- Range of temperature display: 0~40°C/32~104°F
- Insulating condition: Normal environment
- Running programme: Set per 1 week as a cycle
- Installation: Wall mounted or on battery seat
- Working environment temperature: 0~70°C/32~122°F
- Range of temperature adjustment: 5~35°C/41~95°F
- Display accuracy: 0.5°C or 1°F
- Output: Switch relay
- Probe sensor: NTC(10k)1%
- Size(mm): 130*90*27 and 107*78*28
- Contact capacity: 16A/220V(RF electric heating)
5A/220V(RF gas boiler heating)
3A/220V(RF water heating)
OPERATION KEY | ||
NO | KEY | DESCRIPTION |
A | SET | Set key: short press to switch programme mode to manual mode. In programme mode, press “+ ” or “ -” to adjust the value. It will automatically enter into temporary manual mode. |
B | + | Increasing key. |
C | PRG | Clock key: short press to set the clock, long press to set programme. Keys locked/unlocked:press and at the same time for 3 seconds. |
D | Decreasing key. | |
E | Power | Power on/off key. |
RUN MODE Factory Preset Mode
Interval | Monday to Friday | The default value | Saturday and Sunday | The default value | |
1st | 06:00-08:00 | 20°C | 06:00-08:00 | 20°C | |
2nd | 08:00-11:30 | 15°C | 08:00-11:30 | 15°C | |
3rd | 11:30-13:30 | 15°C | 11:30-13:30 | 15°C | |
4th | 13:30-17:00 | 15°C | 13:30-17:00 | 15°C | |
5th | 17:00-22:00 | 22°C | 17:00-22:00 | 22°C | |
6th | 22:00-06:00 | 15°C | 22:00-06:00 | 15°C |
SENDING CONDITION OF THERMOSTAT
- Send once every 20 minutes
- Press on/off key
- Switch over output state
- Communication instruction, be long bright display in normal communication and blinking display in abnormal communication
TRANSCEIVER TIPS
Transceiver LED display indication:
- Power light (green light): bright when power is on.
- Signal light (orange light): long bright light within 10s after power on (match IP), signal light off when it
- Receives match, signal light blinks within 10 seconds when power off.
- Load light/fault light (red light):
- A. When no fault: light on when load output, lights off when no load output.
- B. When fault: light is blinking indicating a fault.
- The signal light blinks once when it does not receive 485 signals for 1 hour (light on 0.25 seconds light off 0.25 seconds), spacing out the light for 2 seconds.
- IP fault (IP: F), the light blinks twice (light on 0.25 seconds light o ff 0.25 seconds), spacing out the light for 2 seconds.
- Light blinks 3 times when it does not receive a wireless signal for 1 hour (light on 0.25 seconds light off 0.25 seconds), spacing out the light for 2 seconds.
- The light blinks 4 times when the built-out sensor is faulty (light on 0.25 seconds light off 0.25 seconds), spacing out the light for 2 seconds..
ADVANCED OPTIONS
Advanced options can be classified in two sets
MODE 1: Turn off the thermostat. , Press for 3 seconds. It will display A01-A09,
Then press to switch between these options.
WIRING DIAGRAM
Reference Link
Download Manual