Introduction

The Harmoni Touch is an intuitive programmable thermostat range used to control either electrical or water underfloor heating systems. It will keep the room at a comfortable temperature whilst minimising energy use. The Touch+ is Wi-Fi enabled and the heating system can be controlled remotely via the app installed on a smart phone.

Technical specifications

Electric Water
Supply voltage 85 –265Vac 50/60Hz 85 –265Vac 50/60Hz
Standby power <2W <2W
Max load 16A 3A
IP class IP21 IP21
Cable specification ≤2.5mm² ≤2.5mm²

INSTALLATION

  • Separate the panel from the back section: insert a screwdriver into the two holes at the bottom of the backplate and prise it open
  • Connect the thermostat according to the wiring instructions on page 6
  • Insert the back panel into the wall box and fix with the screws provided
  • Re-install the front panel whilst ensuring the pins engage properly in the circuit board socket

Wiring instructions

Thermostat symbols & buttons

Wi-Fi connection

  • Scan the QR code or download from the APP store/Google Play
  • Register and log in to the APP with mobile number/email address
  • Click ‘Add Device’ or ‘+’ on the top-right to add device
  • Click ‘Wi-Fi thermostat
  • Operate thermostat. If the Wi-Fi icon flashes quickly, Click ‘Press to connect
  • Enter Wi-Fi password then click ‘Confirm
  • If device is successfully added, device name can be changed and region set. Then click ‘Done
  • Check the actual temperature and set temperature etc., on the control interface

Operation & functions

ON/OFF
Press the button on the right edge of the thermostat to turn on/off

TEMPORARY OVERRIDE TEMPERATURE
With the screen displaying room temperature, press to change the current event temperature setting. The thermostat will revert to the scheduled parameters at the start time of the next event in auto mode.

MODE SELECTION
In the page of detected temperature, press the key in the up-left corner to select the mode.

There are 3 modes:

Auto mode: It is the default mode. Thermostat runs according to event parameters set in Edit Setting to save energy

Manual mode: Runs with the set temperature until altered. Follow these steps:

  • Press Manual Mode to enter temperature setting
  • Press or to set the temperature
  • Press to confirm and return to the screen displaying room temperature

Holiday mode: Runs with the set temperature until the holiday period ends. Follow these steps:

  • Press Holiday Mode to enter holiday setting
  • Press or to set the days of holiday
  • Press to confirm and enter holiday temperature setting

MENU With the screen displaying room temperature, press in the bottom left corner to enter Menu.

Time

  • Day and clock are set here.
  • Press Time to enter day setting
  • Press the day you want to enter hour setting
  • Press to set hour
  • Press to confirm and enter minute setting
  • Press to set minute
  • Press to confirm and go back to Menu
  • Press to return to the screen displaying room temperature

Key lock
Lock all keys to prevent settings from being changed.

Lock Steps

  • Press Key Lock to enter key lock setting
  • Press to select lock
  • Press to confirm and return to the screen displaying room temperature

Unlock steps:

  • On the screen displaying room temperature, press any key then the in the bottom right corner will flash 3 times
  • Press and hold for 3 seconds to unlock

Brightness

  • This option allows the brightness of the display to be changed.
  • Press Brightness to enter brightness setting
  • Press to move up/down or touch any part of the line to set the brightness
  • Press to confirm and back to the Menu

Edit setting
Edit Setting can set and change the parameters. If Holiday Mode or Hold Mode isn’t chosen, the thermostat runs according to the parameters of Edit.

  • Press Edit Setting to enter days selection
  • Press the required day to set
  • Press to enter event selection
  • Press the required event to set and enter the start time hour setting
  • Press or to set start time hour
  • Press to confirm and enter the start time minute setting
  • Press to set start time minutes
  • Press to confirm and enter temperature setting
  • Press to set temperature
  • Press to confirm and return to event selection
  • Press to return to the screen displaying room temperature

DEFAULT PARAMETERS IN EDIT MODE
The table below shows the default parameters.

Day Wake Leave Back Sleep
Mon–Fri 07:00 22.0°C 08:30 19.0°C 17:00 22.0°C 22:00 19.0°C
Sat/Sun 08:00 22.0°C 08:30 22.0°C 17:00 22.0°C 22:00 19.0°C

ADVANCED SETTING

The thermostat provides advanced settings to suit a range of special situations which are normally set by a technician during initial installation.

  • Press Advanced Setting to enter the warning screen
  • Press to enter the advanced setting screen
  • Press to switch screen
  • Press the item to set its parameters
No. Name Default Ranges
1 Room temperature calibration 0°C −5°C to 5°C
2 Floor temperature calibration 0°C −5°C to 5°C
3 Anti-freeze function ON OFF/ON
4 Anti-freeze temperature 5°C 5°C to 15°C
5 Floor temperature limit 30°C 20°C to 50°C
6 Temperature tolerance 1°C 0.5°C/1°C/2°C/3°C
7 Temperature unit °C °C/°F
8 Sensor selection Floor sensor Room/Floor/Both
9 Schedule 5 +1+1 5+1+1/7
10 Output delay 0 seconds 0/30/60/90 seconds
11 Adaptive function OFF OFF/ON
12 Open window OFF OFF/ON
13 Power set 0W 0W to 4500W
14 Energy use
15 Sensor type 0: 3950 0: 3950

1: 3380

2: 3700

3: 3600

4: 3740

16 Factory reset NO NO/YES
  1. Room temperature calibration: Calibrate the temperature detected by the room sensor.
  2. Floor temperature calibration: Calibrate the temperature detected by the floor sensor.
  3. Anti-freeze function: This option is ideal for warming plants and pets with a lower temperature. displays when the thermostat is switched off.
  4. It can also protect the pipework from freezing when using a water heating system.
  5. Floor temperature limit: If both sensors are chosen, the maximum floor temperature value can be set and the system will stop heating if the floor temperature exceeds this value.
  6. Temperature tolerance: Default value is 1°C. The thermostat starts when the room temperature is 1°C lower than set temperature and stops when the room temperature is 1°C higher than set temperature.
  7. Temperature unit: °C and °F can be selected.
  8. Sensor selection:
    • Room sensor: Run by room sensor
    • Floor sensor: Run by floor sensor
    • Both sensors: Run by room sensor with floor temperature limit
    • Schedule: Select a weekly schedule for the Edit Setting. There are 2 options:
  9. Each weekday from Monday to Sunday can be set individually.
    • 5+1+1: Weekdays, Monday to Friday have the same events; Saturday & Sunday can be set individually. 10 Output delay: This option helps avoid inadvertent operation on heating.
  10. Adaptive function: After several days of installation and use, the adaptive function learns that the required temperature has already been reached when the next event begins.
  11. Open window: This function only works when in Room Sensor or Both Sensors mode. When a window is opened, this function detects the sudden change in room temperature and automatically switches off the thermostat for 15 minutes.
    • Energy use: This option allows various data to be
  12. entered and used to calculate energy use. Sensor type: This thermostat is compatible with the following five floor temperature sensors. The default sensor 0–3950 is in the box.

Temperature

The resistance value of the floor sensor at the corresponding temperature point (Ω)
0–3950 1–3380 2–3700 3–3600 4–3740
0°C 32800 26050 30286 34423 34720
10°C 19733 17630 19055 22217 22328
25°C 10000 10000 10000 12000 12000
30°C 7905 8331 8165 9869 9854

Troubleshooting

If you are experiencing problems with your Harmoni thermostat please call our technical department on 01473 559088.

COMMON ERROR CODES

  • E1: Room sensor error
  • E2: Room sensor error

Dimensions
All dimensions are specified in mm

Harmoni product range

Discover Harmoni Heating’s premium range of energy-efficient, intuitive, and well-designed heating solutions with clean, energy-saving technology at the heart of every product.

Visit www.harmoniheating.co.uk to see the full range of harmonic products

REFERENCE:

DOWNLOAD MANUALS:

Harmoni IP21 Touch Digital Thermostat INSTALLATION MANUAL

OTHER MANUALS:

Harmoni IP21 Touch Digital Thermostat Product Specification Guide

Harmoni IP21 Touch Digital Thermostat INSTALLATION MANUAL

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

1 year ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

1 year ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

1 year ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

1 year ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

1 year ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

1 year ago