HA309 thermostat is luxurious in appearance with a large LCD display screen special for electrical heating. It is available for room temperature control in residential, industrial and business premises, controlling the on/off of the electrical heating equipment, to achieve comfort and energy-saving purposes. HA309, the thermostat shows indoor temperature, floor temperature, setting temperature, thermostat output state, and time through the use of micro-computer control technology with big LCD display screen.
HA309’s buttons include Power, Mode, Time, Temperature Regulator(Up/Down)Backlit, Program, Reset, with sensor alarm light (Alarm).
MANUAL MODE、TIMER ON/OFF FUNCTION MODE AND 4 PERIODS MODE CHOICES
Timer on: Press “Mode” for 3 seconds, LCD shows “XX”, press “Up” or “Down” to adjust the parameter.
4 PERIODS’ CORRESPONDING SYMBOLS:
TIMER AND TIMER ON/OFF FUNCTION SETTING
4 EVENTS PROGRAMMING SETTING
Dividing a week into seven separate days or 5+2/6+1(Monday….Friday + Sat-Sun/ Mon….Sat + Sun), each day has four periods with different setting temperature to meet with customer’s individual demand.
The temperature unit default is Fahrenheit, if need to change to Degrees Celsius, please refer to the “parameter setting datasheet”.
Taking Working days (Mon-Fri), Resting days (Sat-Sun) 4 periods setting as an example, reference as below:
5+2 Working days/Resting days | Period 1 | Period 2 | Period 3 | Period 4 | ||||
Starting T / temp.℃ | Starting T / temp.℃ | Starting T / temp.℃ | Starting T / temp.℃ | |||||
Working days(Mon-Fri) | 7:00 | 20℃ [68℉] | 8:30 | 16℃ [61℉] | 17:00 | 22℃ [72℉] | 21:30 | 18℃ [64℉] |
Resting days(Sat-Sun) | 7:30 | 21℃ [70℉] | 9:00 | 20℃ [68℉] | 17:30 | 22℃ [72℉] | 22:00 | 18℃ [64℉] |
Cancelling Working days /Resting days 4 periods function, please as per the tip of the “manual mode, timer on/off function mode and 4 periods mode choices” , switch the mode to manual ”01” or timer on/off “02”.
Taking Working days, Resting day 4 periods setting as an example, this thermostat has installed the following initial values:
6+1 Working days/Resting days | Period 1 | Period 2 | Period 3 | Period 4 | ||||
Starting T / temp.℃ | Starting T / temp.℃ | Starting T / temp.℃ | Starting T / temp.℃ | |||||
Working days(Mon- Sat) | 7:00 | 20℃ [68℉] | 8:30 | 16℃ [61℉] | 17:00 | 22℃ [72℉] | 21:30 | 18℃ [64℉] |
Resting day(Sun) | 7:30 | 21℃ [70℉] | 9:00 | 20℃ [68℉] | 17:30 | 22℃ [72℉] | 22:00 | 18℃ [64℉] |
Take each day’s 4 periods of a week (7days) as an example, reference as below:
7 days 4 periods programmable: Separate each day into 4 periods, each period includes the start time and the programmable temperature. Before following below steps to program the 7days, please layout the starting time and temperature.
Press “Prog”, LCD shows “
Week | Period 1 | Period 2 | Period 3 | Period 4 | ||||
Starting T / temp.℃ | Starting T / temp.℃ | Starting T / temp.℃ | Starting T / temp.℃ | |||||
Mon | 7:00 | 20℃ [68℉] | 8:30 | 16℃ [61℉] | 17:00 | 22℃ [72℉] | 21:30 | 18 ℃ [64℉] |
Tue | 7:00 | 20℃ [68℉] | 8:30 | 16℃ [61℉] | 17:00 | 22℃ [72℉] | 21:30 | 18℃ [64℉] |
Wed | 7:00 | 20℃ [68℉] | 8:30 | 16℃ [61℉] | 17:00 | 22℃ [72℉] | 21:30 | 18℃ [64℉] |
Thu | 7:00 | 20℃ [68℉] | 8:30 | 16℃ [61℉] | 17:00 | 22℃ [72℉] | 21:30 | 18℃ [64℉] |
Fri | 7:00 | 20℃ [68℉] | 8:30 | 16℃ [61℉] | 17:00 | 22℃ [72℉] | 21:30 | 18℃ [64℉] |
Sat | 7:30 | 21℃ [70℉] | 9:00 | 20℃ [68℉] | 17:30 | 22℃ [72℉] | 22:00 | 18℃ [64℉] |
Sun | 7:30 | 21℃ [70℉] | 9:00 | 20℃ [68℉] | 17:30 | 22℃ [72℉] | 22:00 | 18℃ [64℉] |
Power off, press the “mode” and “time” buttons at the same time and hold for 6 seconds, enter the parameter setting interface. Now press “clock” button to page down and “mode” button to page up select the parameter, and press the “up” and “down” button to adjust the parameter value.
NO. | Parameter Setting Description | Default Value | Range | ||
01 CC | Thermostat working time counter | 0-1999 Days | |||
02 Pr | 4 periods mode choices: 52=5+2 4 periods;61=6+1 4 periods;74=7 4 periods; no=have no 4 periods, it is manual or time on/off mode. | no | 5+2 4 periods 6+1 4 periods 7days 4 periods | ||
03 rH | Setting the highest room temperature range | 35℃ | 95℉ | 10-45℃ | 50-113℉ |
04 rL | Setting the lowest room temperature range | 5℃ | 41℉ | 3-9℃ | 37-48℉ |
05 FH | Setting the highest floor temperature range | 45℃ | 113℉ | 20-60℃ | 68-140℉ |
06 FL | Setting the lowest floor temperature range | 5℃ | 41℉ | 5-10℃ | 41-50℉ |
07 CF | Celsius /Fahrenheit, 24/12 hours :12℃,24℃,12℉,24℉ | 24℃ | |||
08 Fr | Low temperature protecting function on/off: 0=off;1=on | 0 | 0-1 | ||
09 dB | Difference setting | 2℃/℉ | 1-9℃/℉ | ||
10 5E | Sensor mode: 0=only inside; 1=only outside;2=both inside and outside. | 0 | 0-2 | ||
11 rC | Room temperature adjustment | 0℃/℉ | -9-9℃/℉ | ||
12 FC | Floor temperature adjustment | 0℃/℉ | -9-9℃/℉ | ||
13 BC | Compensation factor adjustment | 47 | 30-99 | ||
14 dd | Auto recovery: 0=auto recovery;1=no auto recovery;2=power on | 0 | 0-2 |
15 rE | When power is re-supplied, relay time is adjustable. Default =0, relay time is 10 seconds | 0 min | 0-15min | |||
16 DE | Temperature variation caused relay off-on process time set | 0 min | 0-15min | |||
17 O5 | Auto-adjustable function on and off 0=off, 1=on | 0 | 0-1 | |||
18 OP | Preheat output displayed in advance setting | 3h | 0-3h | |||
19 CO | Set preheat output value | 20min | 10min | 10-120min | 5-60min | |
20 Oh | Set only the outside sensor‘s highest temperature | 90℃ | 194℉ | 30-90℃ | 85-194℉ | |
21 OL | Set only the outside sensor‘s lowest temperature | 0℃ | 32℉ | 0-10℃ | 32-50℉ |
NOTE: (*) Only the Auto-adjustable function on, parameter shows No.18, and No.19.
(**) Only choose a single outside sensor, parameter shows No. 20, and No.21.
FLOOR TEMPERATURE EXAMINATION AND SETTING
LOW-TEMPERATURE PROTECTION
Note:
The device should be installed in place at least 32.81 ft. (10 meters) from the electrical service panel.
Note: Connect all wires as per the wiring diagrams and keep it away from water, mud, and other materials.
DOWNLOAD MANUALS:
Hailin HA309 PROGRAMMABLE Thermostat User Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…