Hailin HA309 PROGRAMMABLE Thermostat
HA309 thermostat is luxurious in appearance with a large LCD display screen special for electrical heating. It is available for room temperature control in residential, industrial and business premises, controlling the on/off of the electrical heating equipment, to achieve comfort and energy-saving purposes. HA309, the thermostat shows indoor temperature, floor temperature, setting temperature, thermostat output state, and time through the use of micro-computer control technology with big LCD display screen.
HA309’s buttons include Power, Mode, Time, Temperature Regulator(Up/Down)Backlit, Program, Reset, with sensor alarm light (Alarm).
BASIC FEATURES
- Room temperature setting and measurement
- Floor temperature setting and measurement
- Manual/Timer/4 periods programmable
- 4 periods programmable mode:5+2/6+1/7days
- Celsius /Fahrenheit, 24/12 hours
- Room highest/lowest temperature range setting
- Floor highest/lowest temperature range setting
- Relay Pick-up Times inquiry
- Restoring factory settings
- Sensor fault alarm
- Difference adjustable function
- Sensor for room only/floor only/both room and floor
- Low-temperature protection
- Auto Recovery
STATUS DISPLAY
- Room temperature display
- room setting temperature display
- Floor temperature display
- Floor setting temperature display
- Degrees Celsius show ℃
- Fahrenheit shows ℉
- thermostat output states
- Thermostat output delay display
- Preheat output displayed in advance
- Time display
- Week display
- 4 periods display
SPECIFICATIONS
- Sensing element: NTC
- Set-point range: (could set upper/lower limit)
- Inside sensor:5-35 ℃ [41-95 ℉]
- Outside sensor:5-45 ℃[41-113 ℉]
- Only outside sensor:0-90 ℃[32-194 ℉]
- Operating temperature: 0-45 ℃ [32-113 ℉]
- Operating humidity: 5-95%RH ( non-condensing )
- Button: Silicone Rubber Keypad
- Power supply: AC85-250V,50/60Hz
- Power consumption: <3W
- Wirings: Wiring 0.0016×0.0062sq. in.( 1×4 mm2 wires)
- Switch current rating: 16 A(Resistive)
- Housing: PC +ABS Flame Retardant
- Dimensions:2.95×4.82×1.04” (75×122.5×26.5mm) (W×H×D)
- Hole pitch: 3.29” (83.5 mm)(standard)
- Protection class: IP30
OPERATION
- On/Off: Press “POWER” to turn on, press “POWER” again to turn off, and off the electric heating equipment at the same time.
- Setting temperature: When power is on, press “Down” to reduce the set-point, and press “Up” to raise the set-point. (0.5℃ [1 ℉] changed each press.)
- Electric heating equipment’s control: When the room temperature is 1 ℃ (when the offset is 2 ℉) lower than the setting temperature, the thermostat will put through the power of the electric heating equipment, and the
- LCD will display “ ”; When the room temperature is 1 ℃ (when the offset is 2 ℉) higher than the setting temperature, the thermostat will close the power of the electric heating equipment, and “ ” will disappear.
- If open the ”output delay” function, (refer to No.15 and No.16 of the parameter list): “
” flashing means delaying, and the thermostat will output. When the delay time shows, the LCD shows “ ”, the thermostat output, and put through the power of the electric heating equipment.
MANUAL MODE、TIMER ON/OFF FUNCTION MODE AND 4 PERIODS MODE CHOICES
Timer on: Press “Mode” for 3 seconds, LCD shows “XX”, press “Up” or “Down” to adjust the parameter.
- “01” stands for manual mode, which means after setting the temperature, and no change, LCD shows “
”.
- “02” stands for the timer on/off mode, and LCD shows “
”.
- “03” stands for 4 periods mode, and LCD shows the corresponding time symbol.
4 PERIODS’ CORRESPONDING SYMBOLS:
TIMER AND TIMER ON/OFF FUNCTION SETTING
- Time adjust: press “Time”, till to display “hh:mm” and “hh” flashes, press “Up” or “Down” to adjust hour; press “Time”, “mm” flashes, press “Up” or “Down” to adjust minute; press “Time”, then week flashes, press “Up” or “Down” to adjust week.
- Timer on: Press “Time”, till to display “TIMER ON” and “hh” flashes,press “Up” or “Down” to adjust time on hour, press “Time”, “mm” flashes, press “Up” or “Down” to adjust the time on minute; Press “Time”, till “TIMER OFF” and “hh” flashes. Use the above method, setting the time on/off-hour and minute, the time on/off will be valid until to be canceled.
- Canceling timer on: Method 1: Setting the time on/off-hour and minute as “00”; Method 2: As per the tip of the “manual mode, timer on/off function mode and 4 periods mode choices”,switch the mode to manual “01” or 4 periods “03
4 EVENTS PROGRAMMING SETTING
Dividing a week into seven separate days or 5+2/6+1(Monday….Friday + Sat-Sun/ Mon….Sat + Sun), each day has four periods with different setting temperature to meet with customer’s individual demand.
The temperature unit default is Fahrenheit, if need to change to Degrees Celsius, please refer to the “parameter setting datasheet”.
Taking Working days (Mon-Fri), Resting days (Sat-Sun) 4 periods setting as an example, reference as below:
- Working day setting: period 1 setting: press “Prog” , and LCD shows “
” and “Mon Tue Wed Thu Fri”, “hh” flashes in “hh:mm”, and then press “Up” or “Down” to set hours; press
“Prog”, and “mm” flash in “hh: mm”, and then press “Up” or “Down” to set minutes; press “Prog”, temperature flashes, and then press “Up” or “Down” to set the temperature, and the other time period is set by the same way. - Resting day setting: Press “Prog” till to show “
” and “Sat-Sun” and then set as the above method.
- Please separate each time period when setting the above time period, so as to avoid the system work fault. This thermostat has installed following initial values:
5+2 Working days/Resting days
Period 1 Period 2 Period 3 Period 4 Starting T / temp.℃ Starting T / temp.℃ Starting T / temp.℃ Starting T / temp.℃ Working days(Mon-Fri) 7:00 20℃ [68℉] 8:30 16℃ [61℉] 17:00 22℃ [72℉] 21:30 18℃ [64℉] Resting days(Sat-Sun) 7:30 21℃ [70℉] 9:00 20℃ [68℉] 17:30 22℃ [72℉] 22:00 18℃ [64℉]
Cancelling Working days /Resting days 4 periods function, please as per the tip of the “manual mode, timer on/off function mode and 4 periods mode choices” , switch the mode to manual ”01” or timer on/off “02”.
Taking Working days, Resting day 4 periods setting as an example, this thermostat has installed the following initial values:
6+1
Working days/Resting days |
Period 1 | Period 2 | Period 3 | Period 4 | ||||
Starting T / temp.℃ |
Starting T / temp.℃ |
Starting T / temp.℃ |
Starting T / temp.℃ |
|||||
Working days(Mon- Sat) | 7:00 | 20℃ [68℉] | 8:30 | 16℃ [61℉] | 17:00 | 22℃ [72℉] | 21:30 | 18℃ [64℉] |
Resting day(Sun) | 7:30 | 21℃ [70℉] | 9:00 | 20℃ [68℉] | 17:30 | 22℃ [72℉] | 22:00 | 18℃ [64℉] |
Take each day’s 4 periods of a week (7days) as an example, reference as below:
7 days 4 periods programmable: Separate each day into 4 periods, each period includes the start time and the programmable temperature. Before following below steps to program the 7days, please layout the starting time and temperature.
Press “Prog”, LCD shows “” and “Mon”, as per the initial value datasheet and follow the steps to set the 4 periods program of Mon. “hh” flashes in “hh: mm”, press “Up”, “Down” to set the hour of the program. Press “Prog”, “mm” flashes in “hh: mm”, and press “Up” or “Down” to set the minute of the program. Press “Prog”, the program temperature flashes, and press “Up”, “Down” to set the program temperature.
- Press “Prog”, and “hh” flashes in “hh: mm”, and press “Up”, and “Down” to set the hour of the second-period program.
- Press “Prog”, and “mm” flashes in “hh: mm”, and press “Up”, and “Down” to set the minute of the second-period program.
- Press “Prog”, program temperature flashes, and press “Up” or “Down” to set the adjustable temperature.
- Repeat 1-3 steps to set the 3-4 periods of Mon.
- Press “Prog”, show “
” and “Tue”. Repeat 1-4 steps to set the 1-4 periods of Tue.
- Repeat 1-5 steps to set Wed, Thu, Fri, Sat, Sun.
This thermostat has installed the following initial values:Week
Period 1 Period 2 Period 3 Period 4 Starting T / temp.℃ Starting T / temp.℃ Starting T / temp.℃ Starting T / temp.℃ Mon 7:00 20℃ [68℉] 8:30 16℃ [61℉] 17:00 22℃ [72℉] 21:30 18 ℃ [64℉] Tue 7:00 20℃ [68℉] 8:30 16℃ [61℉] 17:00 22℃ [72℉] 21:30 18℃ [64℉] Wed 7:00 20℃ [68℉] 8:30 16℃ [61℉] 17:00 22℃ [72℉] 21:30 18℃ [64℉] Thu 7:00 20℃ [68℉] 8:30 16℃ [61℉] 17:00 22℃ [72℉] 21:30 18℃ [64℉] Fri 7:00 20℃ [68℉] 8:30 16℃ [61℉] 17:00 22℃ [72℉] 21:30 18℃ [64℉] Sat 7:30 21℃ [70℉] 9:00 20℃ [68℉] 17:30 22℃ [72℉] 22:00 18℃ [64℉] Sun 7:30 21℃ [70℉] 9:00 20℃ [68℉] 17:30 22℃ [72℉] 22:00 18℃ [64℉]
PARAMETER SETTING LIST
Power off, press the “mode” and “time” buttons at the same time and hold for 6 seconds, enter the parameter setting interface. Now press “clock” button to page down and “mode” button to page up select the parameter, and press the “up” and “down” button to adjust the parameter value.
NO. | Parameter Setting Description | Default Value | Range | ||
01 CC | Thermostat working time counter | 0-1999 Days | |||
02 Pr |
4 periods mode choices:
52=5+2 4 periods;61=6+1 4 periods;74=7 4 periods; no=have no 4 periods, it is manual or time on/off mode. |
no |
5+2 4 periods
6+1 4 periods 7days 4 periods |
||
03 rH | Setting the highest room temperature range | 35℃ | 95℉ | 10-45℃ | 50-113℉ |
04 rL | Setting the lowest room temperature range | 5℃ | 41℉ | 3-9℃ | 37-48℉ |
05 FH | Setting the highest floor temperature range | 45℃ | 113℉ | 20-60℃ | 68-140℉ |
06 FL | Setting the lowest floor temperature range | 5℃ | 41℉ | 5-10℃ | 41-50℉ |
07 CF | Celsius /Fahrenheit, 24/12 hours :12℃,24℃,12℉,24℉ | 24℃ | |||
08 Fr | Low temperature protecting function on/off: 0=off;1=on | 0 | 0-1 | ||
09 dB | Difference setting | 2℃/℉ | 1-9℃/℉ | ||
10 5E | Sensor mode: 0=only inside; 1=only outside;2=both inside and outside. | 0 | 0-2 | ||
11 rC | Room temperature adjustment | 0℃/℉ | -9-9℃/℉ | ||
12 FC | Floor temperature adjustment | 0℃/℉ | -9-9℃/℉ | ||
13 BC | Compensation factor adjustment | 47 | 30-99 | ||
14 dd | Auto recovery: 0=auto recovery;1=no auto recovery;2=power on | 0 | 0-2 |
15 rE |
When power is re-supplied, relay time is adjustable. Default =0, relay time is 10 seconds |
0 min |
0-15min |
|||
16 DE | Temperature variation caused relay off-on process time set | 0 min | 0-15min | |||
17 O5 | Auto-adjustable function on and off 0=off, 1=on | 0 | 0-1 | |||
18 OP | Preheat output displayed in advance setting | 3h | 0-3h | |||
19 CO | Set preheat output value | 20min | 10min | 10-120min | 5-60min | |
20 Oh | Set only the outside sensor‘s highest temperature | 90℃ | 194℉ | 30-90℃ | 85-194℉ | |
21 OL | Set only the outside sensor‘s lowest temperature | 0℃ | 32℉ | 0-10℃ | 32-50℉ |
NOTE: (*) Only the Auto-adjustable function on, parameter shows No.18, and No.19.
(**) Only choose a single outside sensor, parameter shows No. 20, and No.21.
FLOOR TEMPERATURE EXAMINATION AND SETTING
- Check the floor temperature: power on status, press “Mode” one time, LCD shows “ ”, “XX.X ℃” or “XX
- ℉” shows the floor temperature. The single sensor setting is without this function.
- Set the floor temperature: power off status: press “Mode” for 7 seconds, until LCD shows “SET XX.X ℃” or “SET XX ℉”, then press “Up” or “Down” to set the floor protection temperature. Default Setting is 35℃ [95 ℉].
LOW-TEMPERATURE PROTECTION
- When the low-temperature protection is valid, the thermostat turns off and the room temperature (or floor temperature) is lower than 5 ℃ [41 ℉], the thermostat will auto start heating and show “ ”, turn on the electric heating equipment, when the room temperature (or floor temperature) increases to 7 ℃ [45 ℉], the thermostat will end output auto.
- For the on /off of the low-temperature protection function, please refer to the “Parameter Setting Table”.
WIRING DIAGRAM
Note:
- Wire all circuits as Class 1, Electric Light or Power Circuits, including the Sensor input.
- The length of the outside sensor cannot be longer than 45.72 ft. (15m). The sensor needs to be housed in a suitable plastic enclosure and the sensor leads voltage have to be rated not less than the maximum rated line voltage of the device.
- Only one sensor style: If only the inside sensor’s fault, LCD shows “E0”; If only the outside sensor’s fault, LCD shows “E1”.
Both inside and outside sensor: inside sensor fault, LCD shows ”E0”, outside sensor fault, LCD shows “E2”.
If any above fault happened, the alarm will flash, and the thermostat will turn off the output.
INSTALLATION
The device should be installed in place at least 32.81 ft. (10 meters) from the electrical service panel.
Note: Connect all wires as per the wiring diagrams and keep it away from water, mud, and other materials.