The instructions are an integral part of the Climapro1 RF and must be handed to the user on completion of the installation in order to comply with the current regulation.
CE Mark
List of contents
Climapro1 programmable room thermostat Wall support for the Climapro1 (*)
Radio receiver
AA LR6 “alkaline batteries” (*) (*) delivered with the wireless version
Fixing
radio receiver on control box unit
Key
IMPORTANT: It is easier to pass the EBUS cable if the pre-cut part is removed.
Key
radio receiver in the control box unit
Key
IMPORTANT: The receiver should be installed outside the appliance if the appliance control box does not have a location for the radio receiver
radio receiver outside appliance
Key
DANGER: Incorrect installation can cause electric shock or damage to the equipment. The electrical connection must be made only by a qualified engineer.
ATTENTION: Do not connect the room thermostat to a 230V terminal.
IMPORTANT: Do not remove the link (RT 24V) from the room thermostat connection on the boiler main PCB.
IMPORTANT: The location of the EBUS terminal block varies according to the heating system. It is always identified by having «BUS» written on it.
Wired room thermostat
connected to a boiler
Key
connected to Smart Wiring Centre 2
Key
Key
connected to Systempro
The radio receiver function is integrated into the Systempro. There is no electrical connection to be made in an installation including a Systempro.
The installation menu is still accessible after commissioning.
Returning to the user menu
The installer menu customizes itself depending on the appliance it is connected to and the connection method.
New functions
Automatic heating curve (if an outdoor sensor is connected)
The automatic heating curve function continually seeks the most suitable value to ensure your comfort and the efficiency of your heating system. The optimum value is obtained approximately 24 hours after the system is started. It is recommended that you activate this function. If the function is deactivated, the heating curve can be set manually by the installer.
Anticipation
The heating system anticipates the fi rst programmed setting change in the morning. This function allows it to reach the programmed temperature rapidly (the function is available and independent for each zone).
Performance index
The performance indicator is calculated from the effi ciency of all appliances over the last 24 hours. The cursor moves along a scale graduated.
Service reminder
Main settings | |
Heating | |
Maximum room T° | 30°C |
Room T° correction | 0°C |
Modulating control | on |
Room T° function | on |
Anticipation | off |
Domestic hot water | |
On/Off | on |
Program | off |
Maximum T° | 60°C |
Recirculation (**) | off |
Cooling | |
On/Off | off |
Program | off |
if an outdoor sensor is connected | |
Automatic heating curve | on |
Correct the outdoor temperature | 0°C |
Settings | |
Efficiency info | off |
Auto time | on |
Service indicator | off |
Climapro1 can be the master or secondary room thermostat:
Master
The “master” room thermostat of the installation has all functions available. The installation comprises only one main room thermostat. It is in general in the principal part of the dwelling (zone 1).
Secondary
The “secondary” room thermostat located in another part has a limited number of functions.
Compatibility of the room thermostat
Room thermostat version | Appliance | Systempro | Smart wiring center 2 |
wired | – | ||
wireless | – |
Fault diagnosis
The following checks should be performed before proceeding onto specifi c diagnostics
Wired room thermostat
IMPORTANT:
If the room thermostat becomes disconnected from the boiler, the heating system uses its own operational settings. Check that these settings are compatible with the installation
IMPORTANT:
The settings are recorded in the room thermostat and the wireless receiver.
If the wireless receiver becomes disconnected from the boiler, the heating system uses its own operational settings. Check that these settings are compatible with the installation.
IMPORTANT: Faults described in this chapter should be rectifi ed by a qualifi ed engineer and if needed by the After Sales Service
Key
In the event of a problem:
Resetting the room thermostat
This function is used to return the room thermostat to factory settings. This restarts the installation assistant.
ATTENTION:
The resetting of factory settings is irreversible. All customised confi guration of the room thermostat will be lost.
Climapro
Description | Unit | Climaplus RF |
Room temperature authorized in the room where the control is installed | °C | 50 |
The maximum authorised temperature of domestic water | °C | 65 |
Power-supply voltage EBUS | V | 24 |
Electrical connection cable section | mm² | 2 x 0.75 |
Max. length of electric connection cables | m | 300 |
Electrical protection | IP20 | |
Pollution rating | 2 | |
Dimensions: | ||
Height | mm | 97 |
Width | mm | 146.5 |
Depth | mm | 35 |
Climapro1 RF
Description | Unit | Climaplus |
Room temperature authorized in the room where the control is installed | °C | 50 |
Maximum authorized temperature of domestic water | °C | 65 |
Power-supply voltage EBUS | V | 24 |
Electrical connection cable section | mm² | 2 x 0.75 |
Max. length of electric connection cables | m | 300 |
Transmission/reception frequency | MHz | 868 |
Electrical protection | IP20 | |
Pollution rating | 2 | |
Frequency of communication with outdoor sensor | min | 15 |
Frequency of communication with the control box | min | 10 |
Average unobstructed working range (*) | m | 100 |
Average range within the home (*) | m | 25 |
Thermostat dimensions: | ||
Height | mm | 115 |
Width | mm | 146.5 |
Depth | mm | 41 |
Wireless receiver dimensions: | ||
Height | mm | 20 |
Width | mm | 171 |
Depth | mm | 58 |
(*) Can vary according to installation conditions and electromagnetic environment |
GLOW-WORM
Address: Nottingham Road, Belper, Derbyshire. DE56 1JT
www.glow-worm.co.uk
Because of our constant endeavour for improvement, details may vary slightly from those shown in these instructions.
Phone: 0020140263_00 – 11/11
Subject to engineering changes
DOWNLOAD MANUALS:
Glow-Worm Climapro1 Wireless Room Thermostat Installation Guide
Glow-Worm Climapro1 Wireless Room Thermostat Installation Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…