Genebre

Genebre 3917 Heat- Cool Digital Thermostat Instruction Manual

Genebre 3917 Heat – Cool Digital Thermostat

KEY FEATURES

• Heat / cool thermostat
• 7 days programmable
• Attractive modern styling
• Surface mounting.
• CE, Rohs approved

TECHNICAL DATA

  • 2*AAA battery power supply
  • Relay contact: 250 VAC (O,25A)
  • Set Point Range: 5 – 350C 0.50C increase)
  • Ambient: OOC – 500C
  • Relative Humidity: 85%
  • Backlight: White
  • Sensor: NTC 10K
  • Accuracy: ± IOC
  • Protection Class: IP30
  • Housing: ABC+PC

DISPLAY

  1. Weekday
  2. Clock
  3. Child lock
  4. Heating on
  5. Manual mode
  6. Program mode
  7. Away mode
  8. Heating mode
  9. Cooling mode
  10. Cooling on
  11. Window opened mode
  12. Current program period

CHILD LOCK
Under child lock ON (refer to menu 11 of parameter setting), the buttons will lock once backlight off. Press and hold the SET button for Ss to unlock it for temporary adjust.

Menu Description Range Default value
01 Temp. calibration for internal sensor -8oC – 8oC 0oC
02 Set Point Max. 5oC – 35oC 35oC
03 Set Point Min.. 5oC – 35oC 5oC
05 Frost Protection Temp. 5oC – 15oC 5oC

10

Display Temp.

0: Room Temp.

1: Set Temp

0

09 Dead zone 0oC – 3oC 0oC

11

Child Lock

1: Lock

0: Unlock

0

12

Open window detect function

1: Enable

0: Disable

0

13 OWD Detect Time 2 – 30 min. 15 min.
14 OWD Drop temp. select

(within detect time)

2,3,4oC. 2oC
15 OWD Delay time select

(Return to previous working status)

10 – 60 min. 30 min.

 

 

17

 

 

Factory reset

0: No

1: Yes, and the press

On/Off button for 5s. wait

until thermostat

restart

 

 

0

MODE SELECT
Short Press SET button to select between Heating Mode & Cooling Mode. Short press PRG button to select between MAN Mode & PRG Mode.

  • Heat mode: Cool mode
  • Heating on: Cooling on

CLOCK & WEEHDAY SETTING
Press and hold the SET button for 5s, set the clock (Min-Hour-Weekday) by pressing and – button, each press of SET button will go to next item setting.

Menu Description
01 Clock setting: minute
02 Clock setting: hour
03 Weekday setting
04 Pre-set temp. for away mode

7 DAYS PROGRAMMABLE SETTING

  • Press and hold PRG button for some time to enter the program setting.
  • Set the schedule (Weekday-Period-Start time-Temp.) by pressing the + and • buttons, each press of PRG button will go to next item setting.

Example:

Period 1 2 3 4
Time Temp. Time Temp. Time Temp. Time Temp.
1,2,3,4,5

(Mon- Fri.)

7:00 22oC 8:30 19oC 17:00 22oC 22:00 19oC
6 (Sat.) 8:00 22oC 8:30 22oC 17:00 22oC 22:00 19oC
7 (Sun.) 9:00 22oC 8:30 22oC 17:00 22oC 22:00 19oC

OPEN WINDOW DETECT FUNCTION (OWD function)

When the Open Window mode is enabled in the parameter setting, the system will automatically stop heating when it detects a sudden drop of room temperature (2°C in 15 minutes as default). This is normally caused when a window or door is opened without turning off the heating device The device will return to the previous mode of operation after 30mins, then disappear. Pressing any button will exit the OWD function during the heating-off period.

PARAMETER SETTING

Under off mode, press and hold SET button and + button for 6s to enter parameter setting. Each press of SET button will go to next item setting. Adjust the value by pressing + or – button.

WIRING DIAGRAM

INSTALLATION AND DIMENSION

IMPORTANT INFORMATION FOR THE CORRECT DISPOSAL OF A THE PRODUCT
At the end of its working life, the product must not be disposed of as urban waste. It must be taken to special differentiated waste collection centers, set up by local authorities or to dealers providing this service. Disposing of an electric or electronic appliance separately avoids possible negative consequences for the environment and health deriving from inappropriate disposal and enables constituent materials to be recovered to obtain significant savings in energy and resources. As a reminder of the need to dispose of electric and electronic appliances separately, the product is marked with a crossed-out wheeled dustbin.

GENEBRE

  • Av. Joan Carles I, 46-48
  • 08908 L’Hospitalet de Llobregat Barcelona (Spain)
  • Tel. +34 93 298 80 00/01 –
  • Fax +34 93 298 80 06
  • e-mail: genebre@genebre.es
  • www.genebre.es

REFERENCE:

DOWNLOAD MANUALS:

Genebre 3917 Heat – Cool Digital Thermostat Instruction Manual

OTHER MANUAL:

Genebre 3917 Heat – Cool Digital Thermostat Product Specification Guide

Genebre 3917 Heat – Cool Digital Thermostat Instruction Manual

wpx_thermostats

Recent Posts

Amex Casino United Kingdom

Amex Casino United Kingdom Instead of free spins, you do well and have winnings that…

6 days ago

Best Online Casino For Roulette

Best Online Casino For Roulette Time and Again is an HTML5 title, best online casino…

6 days ago

Fastest Payout Online Casinos

Fastest Payout Online Casinos Bally Wulff is known for their amazing classic slots and Back…

6 days ago

Bison Casino No Deposit Bonus Codes For Free Spins 2026

Bison Casino No Deposit Bonus Codes For Free Spins 2026 One reels 1 and 5…

6 days ago

Casinos With Fast Payouts

Casinos With Fast Payouts Sky Queen is a medium to high volatility slot offering an…

6 days ago

European Roulette Guide Uk

European Roulette Guide Uk There is a 30x wagering requirement in place on the deposit…

6 days ago