ATTENTION
The documentation refl ects the characteristics of the product, however for regulatory or commercial developments, it is recommended that customers verify the availability of updates relating to this documentation on the Fantini Cosmi website: pdf.fantinicosmi.it
For a quick guide to the basic operation of this system, Fantini Cosmi video tutorials are avail-able in the dedicated section.
The multi-zone system enables different temperature levels to be controlled within the same home.
The temperature of each zone is set on a main device and controlled by one or several devices installed within the rooms. Communication between all devices takes place through radio waves.
The programmable thermostat comes with a cover plate suitable for mounting on recessed or wall mounted boxes.
warning: Installation must be carried out by qualifi ed personnel, in compliance with the requirements concerning installation of electrical devices. Make sure that the power supply is disconnected before making any connections or working on the device. Make the electrical connections as shown in the connection diagrams.
CONNECTION EXAMPLE
DESCRIPTION OF KEYS/DISPLAY AND OPERATING INSTRUCTIONS
The CH180RF programmable thermostat has 6 multi-function keys through which the entire system can be controlled.
When not in use, the programmable thermostat switches off the backlight and the messages on the keys and goes into Stand-by mode (battery saving). To exit this mode, press and hold one of the 6 keys until the backlight turns on. The back-light duration and its intensity can be changed in the PROG.ADV. advanced programming menu (see page 40).
PLEASE NOTE: to use the multi-zone functions, exit the stand-by mode and then press the desired function key
LANGUAGE (Default = Italian)
It is used to select one of the following languages: Italian, English, Russian, French, Spanish, German. Press PROG for at least 3 seconds to access the PROG.ADV. advanced programming menu. Use the ◄► keys to select the item correspond-ing to the language set, use the ▲▼ keys to select the new language and confi rm with ESC.
Press PROG briefl y to access the PROG.USER user programming menu. Use the ◄► keys to select the year, month, day, hour, minutes; set the correct value with the ▲▼ keys and press the ESC key to confi rm and exit.
On the CH180RF you can activate and display the main operating modes for the whole system or for a single zone.
To select a zone, exit the STAND-BY mode and press ZONE until the selected zone number is displayed. To assign a name to the zone, see page 45.To exit the zone, press ESC or after 30 seconds the CH180RF returns to the main screen.
NOTE:
By pressing MODE, you can select, in cyclic sequence, the different operating modes: AUTO -> MAN -> HOLIDAY -> JOLLY.
If MODE is pressed from the main screen, all zones will be in the mode selected
AUTOMATIC MODE (AUTO)
For each day of the week, one of the programmable temperatures TCOMF (comfort), TECO (saving) and TA (OFF) can be associated to each half hour.
Weekly profi le customisation
Temperature customisation (TCOM, TECO)
After selecting the AUTO mode, press DISP to set the desired temperature.
MANUAL MODE ( MAN)
In this mode, the programmable thermostat maintains the fi xed set temperature TMAN, which can be changed with the ▲▼keys, until another operating mode is selected.
Temperature customisation (TMAN)
After selecting the MAN mode, press DISP to set the desired temperature.
TEMPORARY MODE ( LOLLY)
It maintains the set temperature up to the time and date selected. When the set time and date is reached, the programma-ble thermostat returns to the previously active program.
General JOLLY
Zone JOLLY
Press ZONE to select the desired zone and then press MODE until JOLLY appears. The JOLLY screen is displayed. Press OK and using the ◄► and ▲▼ arrows, set the time (with 30 min. resolution) and the day until which you want to maintain the set temperature.
Editing the set parameters
After selecting the JOLLY mode, press DISP, set the desired temperature, or update the set parameters.
Editing the set parameters
After selecting the JOLLY mode, press DISP, set the desired temperature, or update the set parameters.
DAILY MODE (HOLIDAY)
This mode is used for daily programming, regardless of the days of the week set previously. As in the AUTO program, a time profi le can be confi gured by associating one of the programmable temperatures TCOMF (comfort), TECO (saving) and TA (OFF) to each half hour.
HOLIDAY profi le customisation
From HOLIDAY mode, select the zone you want to edit with ZONE; then press PROG. The HOLIDAY profi le to be edited will be displayed.
Use the ◄► keys to scroll through the time histogram and use the ▲▼ keys to set the temperature: TCOMF or TECO , OFF .
You can exit programming by pressing ESC. While by pressing OK, you can copy the newly set profi le to the other zones.
Temperature customisation (TCOM, TECO)
After selecting the HOLIDAY mode, press DISP to set the desired temperature.
SHUTDOWN (OFF)
It is activated by pressing OFF. With OFF, the selected system or zone is switched off. During WINTER mode, it maintains the set antifreeze temperature TA (default is 5°C). Alternatively, TA can be changed in the PROG.ADV. menu (see page 43).
KEY LOCK AND UNLOCK WITH PASSWORD
To unlock the display enter the code using the◄►▲▼ keys and press OK
NOTE: with the KEY LOCK WITH PASSWORD function, the CH120RF keys connected to the MASTER CH180RF are also locked.
USE STATISTICS
For statistical purposes, the programmable thermostat records the total consumption of the heating and cooling hours. To display, select DISP and use the ◄► keys to reach the UTILIZATION menu and press OK.
The following are the statistics available and can be displayed with the ◄► keys:
The message RSSI appears on the device.
It indicates the quality of the signal received from devices connected directly to the CH180RF.
NOTE: satisfactory RSSI value > 50
The presence of one or several faults of the various devices that make up the multi-zone system is indicated with the mes-sage FAULT fl ashing on the display.
To display the fault code, press DISP. Using the ◄► keys select the FAULT menu and press OK. Use the ◄► keys to scroll through the list of faults and identify, in the table below, the problem and the action to be taken. The fault is cancelled automatically when the problem has been solved.
ERROR | DEVICE | FAULT | ACTION |
020 | O60RF | Incorrect assembly | Make sure that the head is mounted properly on the valve, if the problem persists contact technical |
support | |||
010/ 021 / 030 | O60RF | Mechanical / electronic error | Contact technical support |
022 | O60RF | Temperature reading error | Contact technical support |
040 | O60RF | Flat battery | Replace the batteries |
001 | CH120RF | Flat battery | Replace the batteries |
006 | CH120RF | No radio communication Replace the batteries if the problem persists contact technical support | |
050 | O60RF | No radio communication Replace the batteries if the problem persists contact technical support | |
050 | CH175 | No radio communication Check the mains power supply, if the problem persists contact technical support |
Press ESC for 5 seconds. The message “LOCKED” will appear on the display for 30 seconds.
When the batteries are fl at, the display shows the fl ashing symbol
NOTE
ADVANCED PROGRAMMING (PARAMETER SETTINGS)
The confi guration menu contains the parameters that defi ne the operation of the programmable thermostat according to how the system was implemented. To access, from the MAIN SCREEN, press PROG for 3 seconds.
Backlight
Display intensity
Daylight saving time (Default = Yes)
Winter/summer (Default = Winter)
PLEASE NOTE: in WINTER the dehumidifi cation function cannot be activated.
Antifreeze temperature (Default = 5°C)
PLEASE NOTE: in SUMMER the function cannot be activated.
RH Relative humidity (Default = —)
PLEASE NOTE in WINTER the function cannot be activated.
Relay function (Default = OFF)
Press PROG for at least 3 sec. and use the ◄► keys to reach the desired page.
The programmable thermostat is equipped with a relay that can be used for different system configurations; the relay operating modes are listed below:
Zone Names
The names of the zones range between:
OFFSET (Default = 0.0°C)
Press PROG for at least 3 sec. and use the ◄► keys to reach the desired page.
Use the ▲▼ arrows to set the unit of measure for the entire system, either degrees Celsius or degrees Fahrenheit.
Language (Default = Italian)
External probe (EXT IN) (Default = no function)
Press PROG for at least 3 sec. and use the ◄► keys to reach the desired page. By connecting an EC18 – EC19 – EC20 temperature probe, you can use the following functions:
VIS: Display of temperature detected by the external probe.
REG: adjustment of room temperature with the external probe;
HIGH: maximum safety temperature exceeded alarm. This is a safety threshold, only active in the WINTER season and disables the system. To activate, press OK and set the desired maximum threshold using the ▲▼ keys;
LOW: minimum safety temperature exceeded alarm. This is
a safety threshold, only active in the SUMMER season and
disables the system. To activate, press OK and set the desired minimum threshold using the ▲▼ keys;
DEW: fl oor system condensate formation control in summer through control of the dew point (a fl oor probe is required).
NOTE: with the control active, when a zone switches the cooling system off, the symbol
Connecting a voltage-free contact allows you to use the following functions:
Reset – confi guration reset
Waste disposal
The symbol of the crossed-out wheeled bin indicates that the products must be collected and disposed of separately from household waste. The batteries and integrated accumulators may be disposed of together with the product. They will be separated at the recycling facilities. A black bar indicates that the product was placed on the market after August 13th, 2005. Participating in the separate collection of products and batteries contributes to the correct disposal of these materials and therefore avoids possible negative consequences for the environment and human health. For more detailed information on the collection and recycling programmes available in your country, contact the local authorities or the sales point where you purchased the product.
Download Manual:
Fantini cosmi CH180RF TOUCH-SCREEN PROGRAMMABLE THERMOSTAT INSTRUCTIONS Manuals
Other Manual:
Fantini cosmi CH180RF TOUCH-SCREEN PROGRAMMABLE THERMOSTAT Product Specification Guide
Fantini cosmi CH180RF TOUCH-SCREEN PROGRAMMABLE THERMOSTAT INSTRUCTIONS Manuals
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…