N.B Please note, when first powered or in the event of a power loss the time will be flashing and the time and date will need to be set. Use the dial to adjust the hour then press >. Repeat this to set the minute, day date, and month date. Next set the year by using the dial to adjust the first digit then press > and repeat for all 4 digits. It is recommended to leave the thermostat to climatize for 40 minutes before user operation.
Display and Button Functions
Setting the Time and Date (tINE)
N. B Please note, when first powered or in the event of a power loss the time will be flashing and the time and date will need to be set. Follow steps 2 – 6 to set the time on the first setup. Changes between summer and winter time are handled automatically by the unit.
Operation Modes
Operation Modes: AUTO, MAN, OFF Press > in the home screen to choose operation mode.
AUTO
Temporary manual override of the set temperature
In Auto mode, the user can turn the dial to adjust the set temperature as below:-
Temporary set temperature range: 5oC – 35oC. Default: 21oC
N.B: The temporary set temperature will not replace the original program event’s set temperature. When the program event ends, it will return to the default heating program automatically.
MAN
Permanent manual override of the set temperature.
OFF
Turn the heating off permanently.
All Day Mode (AL)
To adjust the temperature in All Day mode, turn the dial to the desired temperature then press > to confirm and automatically return to the home screen. Press < in the home screen to exit All Day mode and return to Auto mode. Heating under All Day mode will be on until 23:59 that day. At 23:59, the unit will exit All Day mode and return to Auto mode. Set temperature range: 5oC – 35oC. Default: 21oC
Holiday Mode (HOLI)
To adjust the settings in Holiday mode, turn the dial to adjust the holiday days, and press > to confirm. Then turn the dial to adjust the set temperature, press > to confirm, and return to the home screen. Press < in the home screen to exit Holiday mode and return to Auto mode. Holiday mode days setting range: 1 – 99 days. Default: 1 day Set temperature range: 5oC – 35oC. Default: 7oC
N.B: The Days(Holiday) will numerically countdown. Once the countdown has finished normal operation will resume. It may be advisable to set the Holiday mode 1 day less so the house is back up to temperature for your return.
Main Menu
In the home screen, press and hold > for 3 seconds then release to enter the main menu. Use the dial to choose between tINE, ProG, CoPy, tEcH, and rESE. Press > to enter the desired setting. Press < to
return to the Home screen.
Copy Function (CoPy)
The unit is provided with a copy function which allows an adjusted program to be copied to another day.
N.B. This function only works in 7 Day setting. To operate the copy function:-
Backlight On/Off (LIGH)
The backlight can be turned permanently on/off.
Resetting the Unit (rESE)
Resetting the unit will return the thermostat to the default setting. The time, date, and landlord service settings will all be maintained.
Factory Pre-Set Programme
This unit has been designed to be a simple-to-use thermostat, requiring minimal user intervention with a pre-programmed heating profile. The pre-set heating times and temperatures will suit most people (see table below). Operation setting range: 5/2 day, 7 days, 24 Hours. Default: 5/2 Day Events setting range: 6 events or 4 events. Default: 6 events
Pre-Set Temperatures: 5/2 Day
Mon-Fri pre-set time and temperature settings
Sat & Sun pre-set time and temperature settings
Pre-Set Temperatures: 7 Day
In 7 day setting, the pre-set settings are the same as the 5/2 Day program.
Pre-Set Temperatures: 24 Hours
In 24hr setting, the pre-set settings are the same as Mon-Fri of the 5/2 Day program.
Setting the Operation Mode (5/2 day, 7 days, 24hr) (ProG)
Setting the Programme (ProG)
5/2 Day
7 Day
24 Hour
All Day Mode | |
All day mode temperature | 5oC-35oC (Default: 21oC) |
Holiday Mode | |
Holiday mode temperature | 5oC-35oC (Default: 7oC) |
Holiday mode days | 1-99 days (Default: 1 day) |
Default Mode | |
Temporary set temperature | 5oC-35oC (Default: 21oC) |
Program event start time | 00.00-24.00 (See 5.1 for details) |
Program event set temperature | 5oC-35oC (See 5.1 for details) |
Program operation mode | 5/2 day, 7 day, 24hr (Default 5/2 day) |
Number of programs | 4 or 6 (Default 6) |
Manual Mode | |
Manual mode temperature | 5oC-35oC (Default: 21oC) |
Delayed Start | |
DS | Off or On (Default Off) |
TPI | |
TPI | Off, 3 cycles or 6 cycles (Default Off) |
OFF Mode (Frost Protection) | |
Frost protection start temperature | 5oC |
Frost protection exit temperature | 7oC |
Service | |
SERS | OFF or 1-4 (Default: Off) (See 9.1 for details) |
Service DATE | 28-366 days (Default 365 days) |
Other Functions | |
Operation MODE | Auto, Manual, Off (Default: Auto) |
Temperature calibration ADJ | 3.0oC-3.0oC (Default: 0oC) |
SWING | 0.5oC-2.0oC (Default: 1oC) |
Display backlight | Off/On (Default: Off) |
Thermostat Technical Settings
Power supply | 230VAC, 3(1)A SPDT |
Temperature Sensor Type | +/- 1oC at 20oC |
Total Switch Rating | 3(1)A 230 VAC |
Contact Type | SPDT (Volt Free changeover contacts) |
Plastic | Thermoplastic, flame retardant |
Protection Rating | IP30 |
Dimensions | 95mm (L) x 95mm (W) x 39mm (D) |
BST/GMT Time Change | Automatic |
Factory Pre-Set Programme | Yes, see 5.1 for details |
Complies with | EN 60730-1, EN 60730-2.7, EN 55014- 1:2006+A1:2009+A2:2011, EN 61000- 3-2:2014, EN 61000-3-3:2013, EN 55014-2: 2015, EN 60730-1:2011, EMC Directive 2014/30/EU, LVD Directive 2014/35/EU |
Installation
Installation Safety Instructions
The unit must be installed by a suitably qualified person in accordance with the latest IEE Wiring Regulations. Isolate mains supply before commencing installation. Please read all instructions before proceeding. Ensure that the fixed wiring connections to the mains supply is via a fuse rated at not more than 3 Amps and a Class ‘A’ switch having a contact separation of a minimum of 3mm in all poles. The recommended cable sizes are 1.0mm sqr or 1.5mm sqr. No earth connection is required as the product is double insulated but ensures continuity of earth throughout the system.
General Safety Instructions
This product complies with the essential requirements of the following EC Directives:
Please leave the user instructions with the end user where they should be kept in a safe place for future reference.
WARNING: ALWAYS ISOLATE THE AC MAINS SUPPLY BEFORE INSTALLING. THIS PRODUCT MUST BE FITTED BY A COMPETENT PERSON, AND INSTALLATION MUST COMPLY WITH THE GUIDANCE PROVIDED IN THE CURRENT EDITIONS OF BS767 (IEE WIRING REGULATIONS) AND PART “P” OF THE BUILDING REGULATIONS.
WARNING: DO NOT FIT THE RECEIVER TO A BACK PLATE THAT IS LIFE. SWITCH OFF THE MAINS BEFORE FITTING THE BACK PLATE AS LIVE AND NEUTRAL CONTACTS MAY TOUCH WHILE MOUNTING THE RECEIVER ON THE PLATE AND DAMAGE THE PRODUCT.
Maintenance
Always isolate the mains supply before commencing any work, servicing or maintenance on the system. And please read all instructions before proceeding. Arrange for an annual maintenance and inspection schedule to be carried out by a qualified person on every part of the heating and hot water system.
Fitting the Programmable Room Thermostat
The ideal position to locate the Programmable Room Thermostat is about 1.5m above floor level, in a location where the thermostat is accessible, reasonably lit, and free from extremes of temperature and draughts. Do not position the thermostat near sources of heat, such as radiators, lights, TV, direct sunlight, or on an outside wall.
Wiring Diagram
Landlord Service (SEr)
Setting the Landlord Service (SErS)
Setting the Due Date (DAtE)
To set the due date, enter the landlord service settings (see section 9.1) and use the dial to select DAtE then press >. Use the dial to set the due date (between 28-366 days) then press > to confirm and return to landlord service settings.
Changing the Password (CODE)
To change the password, enter the landlord service settings (see section 9.1) and use the dial to select CODE then press >. Use the dial to set the first digit of the new password then press > to move to the next digit. Repeat this for all 4 digits. On the last digit, press > to confirm the new password. Then re-enter the chosen password using the dial and > button. On the last digit press > to confirm. If both inputted passwords match, the new password will be saved and the unit will return to the home screen. If the inputted passwords do not match, the unit will return to the landlord settings menu and this step (section 9.3) should be repeated.
WARNING: Interference with sealed parts renders the guarantee void. In the interests of continuous product improvement, we reserve the right to alter designs, specifications, and materials without prior notice and cannot accept liability for errors.
ESi Controls Limited
sales@esicontrols.co.uk www.esicontrols.co.uk
Download Manual:
ESI ESRTP5 Programmable Room Thermostats Installation Instructions
ESI ESRTP5 Programmable Room Thermostats Installation Instructions
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…