Congratulations on choosing the Emerson Blue Easy Reader Thermostat. Blue Easy Reader is designed to be the most accessible thermostat you have ever used. This thermostat features large numbers and letters for easier viewing, and a “one button to one function” operation for total simplicity. As with all Emerson Blue thermostats, no other brand offers better temperature accuracy or reliability. Blue Easy Reader Thermostat consists of two parts, the base or wall plate mounted on your interior wall and the display and control front that snaps onto the base piece. Depending on your installation, your Blue Easy Reader may be battery-powered or system powered. Either way, it is recommended to keep fresh batteries installed. Batteries are accessible by removing the control front from the base.
Whenever “Change ” appears in the display, new premium brand AA alkaline batteries should be installed. If the house will be unoccupied for an extended period and is displayed, install new batteries before leaving. If you plan to use Blue Easy Reader as a non-programmable thermostat, please turn the page to get started. Keep in mind that Easy Reader can also be a programmable thermostat if you should change your mind later. Please call 800-284-2925 if you need assistance in adjusting to programmable. If you plan to use Easy Reader as a programmable thermostat, please skip to page 6.
THERMOSTAT DISPLAY OVERVIEW
USING YOUR THERMOSTAT
If your heating or A/C system is a heat pump, the system automatically activates Auxiliary Heating when the outside temperature is too cold for the heat pump to efficiently heat the home. You can manually activate the auxiliary heating by pressing and holding the Heat button until Aux changes to Aux. To turn the manual auxiliary off press the Heat button again. Now enjoy the simple operation of your Easy Reader Non-Programmable Thermostat.
THERMOSTAT DISPLAY OVERVIEW
OTHER DISPLAY ICONS FOR PROGRAMMING
To change your thermostat to be Programmable, Item 14, Schedules per Week, in Confi guration Menu must be changed from P0 to P7. See pages 18-19, “Setting Up Your Thermostat Options.”
SET THE CURRENT TIME AND DAY
This thermostat is set up for 7 independent da programming with 2 or 4 time/temperature periods per day. If the factory programming meets your needs, skip to page 16, using your thermostat. If you wish to change the heating or A/C schedules, please proceed to the “Programming Your Thermostat” section.
Factory Pre-Programmed schedule for the default two-period Day / Night programs
Day | Night | |||
Heating Program | 6:00 AM | 70°F | 10:00 PM | 62°F |
A/C Program | 6:00 AM | 75°F | 10:00 PM | 78°F |
Factory Pre-Programmed schedule for four periods per day, all days of the week
Wake Up (Morning) | Leave For Work (Day) | Return Home (Evening) | Go To Bed (Night) | |||||
Heating Program | 6:00 AM | 70°F | 8:00 AM | 62°F | 5:00 PM | 70°F | 10:00 PM | 62°F |
A/C Program | 6:00 AM | 75°F | 8:00 AM | 83°F | 5:00 PM | 75°F | 10:00 PM | 78°F |
HEATING AND A/C WORKSHEET
The Heating and A/C Worksheet on page 14 allow you to pencil in your own program times and temperatures. Factory settings are listed on Monday (for Monday thru Friday), Saturday and Sunday. If you are re-programming all 7 days, fill in all lines with the times and temperatures you want. Use this worksheet as a guide to reprogramming the thermostat. Keep the following guidelines in mind when planning your program.
COPY PROGRAM
When programming your thermostat, you may copy the program from one day to another day. To copy a program:
Fill in the blank worksheet with your desired times and temperatures:
Worksheet for Re-Programming 7-Day Program
Heating Program | Wake Up (Morning) | Leave For Work (Day) | Return Home (Evening) | Go To Bed (Night) | ||||
MON | 6:00 AM | 70°F | 8:00 AM | 62°F | 5:00 PM | 70°F | 10:00 PM | 62°F |
TUE | ||||||||
WED | ||||||||
THU | ||||||||
FRI | ||||||||
SAT | 6:00 AM | 70°F | 8:00 AM | 62°F | 5:00 PM | 70°F | 10:00 PM | 62°F |
SUN | 6:00 AM | 70°F | 8:00 AM | 62°F | 5:00 PM | 70°F | 10:00 PM | 62°F |
A/C Program | Wake Up (Morning) | Leave For Work (Day) | Return Home (Evening) | Go To Bed (Night) | ||||
MON | 6:00 AM | 75°F | 8:00 AM | 83°F | 5:00 PM | 75°F | 10:00 PM | 78°F |
TUE | ||||||||
WED | ||||||||
THU | ||||||||
FRI | ||||||||
SAT | 6:00 AM | 75°F | 8:00 AM | 83°F | 5:00 PM | 75°F | 10:00 PM | 78°F |
SUN | 6:00 AM | 75°F | 8:00 AM | 83°F | 5:00 PM | 75°F | 10:00 PM | 78°F |
ENTER HEATING PROGRAM
ENTER A/C PROGRAM
Press A/C to place the thermostat in air conditioning mode. Set the A/C program following the “Enter Heating Program” steps
USING YOUR THERMOSTAT – PROGRAMMABLE MODE
AUXILIARY HEATING
Programmable or Non-Programmable If your heating or A/C system is a heat pump, the system automatically activates Auxiliary Heating when the outside temperature is too cold for the heat pump to efficiently heat the home. You can manually activate the auxiliary heating by pressing and holding the Heat button until Aux changes to Aux. To turn the manual auxiliary off press the Heat button again.
TEMPORARY PROGRAM OVERRIDE
This feature will override the programmed temperature setting for a two-hour period. Press or buttons to adjust the temperature. The display will show “Hold Temp” to the left of the desired temperature. To cancel the temporary setting and return to the program, press Run. Example: If you turn up the heat during the morning program, it will be automatically lowered later, when the temporary hold period ends.
PERMANENT TEMPERATURE HOLD
The Permanent Temperature Hold feature bypasses the program and allows you to adjust the temperature manually as needed. The temperature you set in Hold will be maintained indefinitely. Press or buttons to adjust the temperature. The display will show “Hold Temp” to the left of the desired temperature. Press the Hold button to maintain the new temperature.
“Hold Temp” will change to “Hold”. To cancel the permanent hold setting at any time and return to the program, press the Run Sched button. Example: You turn up the heat during the Morning program and press the Hold button, it will remain at the new temperature until you press Run Sched or you manually adjust to another temperature.
SYSTEM DIAGNOSTICS
“Call for Service” will be displayed if your heating orB air conditioning system has the diagnostic capability and needs a qualified service technician to service the equipment. On some systems with diagnostic capability “Call for Service” will flash on the thermostat display
when a technician is needed.
CONFIGURATION MENU ITEMS
Your thermostat has several configuration items. Some of these items will be set by the installer and should not be changed. However, these settings should be recorded for future reference if the installer settings are inadvertently changed To enter the Configuration Menu, the Easy Reader thermostat must be in Heat or A/C. Press and hold the Menu button for five seconds. Once in the menu, each press of the Menu Button will step to the next menu item. Menu item options can be changed by pressing the buttons
MENU ITEM | DISPLAY (DEFAULT) | OPTIONS | COMMENTS | |
1 | System Configuration | (MS 2) | HP1, HP2, SS1 | Installer Set |
2 | Electric Heat Fan | (GAS) | ELE | Installer Set |
3 | EMR | E (On) | Off | |
4 | Heat Cycle Rate | Cr HEAT (ME) | SL, FA | SS1, MS2 only |
5 | Heat Pump Configuration Cycle Rate | Cr Heat / A/C (ME) | SL, FA | Heat Pump HP1, HP2 only |
6 | A/C Cycle Rate | Cr A/C (ME) | SL, FA | SS1, MS2 only |
7 | Auxiliary Heat Cycle | Cr AUX Heat (FA) | SL | HP1, HP2 only |
8 | Compressor Lock-out | CL (OFF) | On | Installer Set |
9 | System Mode Configuration | (Heat, A/C, Off) | Heat, Off, Fan / Heat, Off / A/C, Off | Installer Set |
SETTING UP YOUR THERMOSTAT OPTIONS
MENU ITEM | DISPLAY (DEFAULT) | OPTIONS | COMMENTS | |
10 | Compressor Optimization | CO (OFF) | On | Installer Set |
11 | LCD Display Light | dL (On) | Off | |
12 | Temperature Display Adj. | HI (0) | 1 to 5 Hi or LO | |
13 | oF/oC Selection | (oF) | oC | |
14 | Schedules per week | P (0) | 7 | |
15 | Periods per day | PS (2) | 4 | |
16 | Fast HEAT | HEAT FA (On) | Off | |
17 | Fast A/C | A/C FA (On) | Off | |
18 | Daylight Savings Time | dS (On) | Off | |
19 | Temperature Range Heat Limit | HL (99) | 62-98 | |
20 | Temperature Range A/C Limit | LL (45) | 46-82 | |
21 | Dual Fuel / Electrical Fuel | dF (0) | 1-9 | HP1, HP2, Installer Set |
22 | Compressor Delay | Cd (60) | 00-99 | HP1, HP2, Installer Set |
23 | O/B Output Configuration | On A/C (O) | On Heat (B) | Installer Set |
24 | Exit Menu |
CONFIGURATION MENU DESCRIPTIONS
1 | Configuration for your Heating or A/C system | Set by installer to match your system. Record the setting. |
2 | Electric or Gas fan operation | Set by installer to match your system. Record the setting. |
3 | EMR | Energy Management Recovery (EMR) [will not appear if thermostat is set for Non-Programmable] Default setting is On. EMR starts your system early so the temperature in your home is at the desired temperature at the beginning of a program period. |
4 | Heat Cycle Rate Setting (if system is MS or SS) | Default setting is ME (medium), if you desire a longer heating cycle set to SL (Slow) or shorter cycle set to FA (Fast). |
5 | Heat Pump Cycle Rate Setting (if system is Heat Pump) | Default setting is ME (medium), if you desire a longer heat pump cycle set to SL (Slow) or shorter cycle set to FA (Fast). |
6 | A/C Cycle Rate Setting or Aux Heat Cycle Rate | Default setting is ME (medium) if you desire a longer cooling cycle set to SL (Slow) or shorter cycle set to FA (Fast). |
7 | Auxiliary Heat Cycle Rate (if system is Heat Pump) | Default setting is FA (Fast). If you desire a longer Aux heat cycle set to SL (Slow). |
8 | Compressor Lockout Protection | Set by installer to match your system. Record the setting. |
9 | System mode configuration | Set by installer to match your system. Record the setting. |
10 | Compressor Optimization | Set by installer to match your system. Record the setting. |
11 | Display light | The display light is defaulted on so when any button is pressed the light will illuminate the display. When set to Off, the light will not turn on. |
12 | Temperature Display Adjustment | The Easy Reader thermostat was accurately set at the factory. However, if you want to change the temperature, you can adjust the reading by plus or minus five degrees. Your thermostat displays to match your previous thermostat. |
13 | Fahrenheit or Celsius display | The Easy Reader can display temperature in either °F or °C. |
14 | Schedules Per Week | The Easy Reader thermostat is shipped from the factory as an easy to operate non-programmable thermostat (P 0). However if you want the energy saving benefits of a programmable thermostat, a seven day programming option (P 7) is available. |
15 | Periods per Schedule | If programming is selected you can choose between 2 period (Day, Night) per day or 4 period (Morning, Day, Evening, Night) per day. |
16 | Fast Heat | If your system is a multi-stage and/or Heat Pump you can select to have the additional stage of heating come on anytime the temperature setting is adjusted up by three degrees or more. If you do not desire this feature, select Off. |
17 | Fast A/C | If your system is a multi-stage Air Conditioner or multi-stage Heat Pump you can select to have the additional stage of A/C come on anytime the temperature setting is adjusted down by three degrees or more. If you do not desire this feature, select Off. |
18 | Daylight Savings Time adjustment | In Programmable mode the Easy Reader thermostat can automatically change the time in spring and fall. If you do not desire this feature select Off. |
19 | Temperature Range Heat Limit | The Easy Reader thermostat can be set to limit the highest desired temperature in heat to anywhere between 98° and 62°. |
20 | Temperature Range A/C Limit | The Easy Reader thermostat can be set to limit the lowest desired temperature in A/C to anywhere between 46° and 82°. |
21 | Dual Fuel Setting | Set by installer to match your heat pump dual fuel system. Record the setting. |
22 | Compressor Delay for Dual Fuel | Set by installer to match your heat pump dual fuel system. Record the setting. |
23 | O/B Output Configuration | Set by installer to match your heat pump system. Record the setting. |
24 | Exit | |
18 | Daylight Savings Time adjustment | In Programmable mode the Easy Reader thermostat can automatically change the time in spring and fall. If you do not desire this feature select Off. |
19 | Temperature Range Heat Limit | The Easy Reader thermostat can be set to limit the highest desired temperature in heat to anywhere between 98° and 62°. |
20 | Temperature Range A/C Limit | The Easy Reader thermostat can be set to limit the lowest desired temperature in A/C to anywhere between 46° and 82°. |
21 | Dual Fuel Setting | Set by installer to match your heat pump dual fuel system. Record the setting. |
22 | Compressor Delay for Dual Fuel | Set by installer to match your heat pump dual fuel system. Record the setting. |
23 | O/B Output Configuration | Set by installer to match your heat pump system. Record the setting. |
24 | Exit |
CONFIGURATION MENU RECORDING (Default Settings in Bold) | ||||
System Configuration | MS 2 | HP 1 | HP 2 | SS 1 |
Electric Heat Fan | Gas | Ele | ||
EMR (E) | On | Off | ||
Heat Cycle Rate (Cr Heat) | ME | SL | FA | |
Heat Pump Configuration Cycle Rate (Cr Heat A/C) | ME | SL | FA | |
A/C Cycle Rate (Cr A/C) | ME | SL | FA | |
Auxiliary Cycle Rate (Cr Heat) | FA | SL | ||
Compressor Lockout (CL) | Off | On | ||
Mode Configuration | Heat, A/C, Off | Heat, Off, Fan | Heat, Off | A/C Off |
Compressor Optimization (CO) | Off | On | ||
Display Light (dL) | On | Off | ||
Temperature Display Adjust | 0 Hi | 1 to 5 Hi | 1 to 6 Lo | |
°F/°C Selection | °F | °C | ||
Schedules per Week (P) | 0 | 7 | ||
Periods per Schedule Day (PS) | 2 | 4 | ||
Fast Heat (Heat FA) | On | Off | ||
Fast A/C (A/C FA) | On | Off | ||
Temperature Range Heat Limit (HL) | 99° | (62° to 99°) | ||
Temperature Range A/C Limit (LL) | 45° | (45° to 82°) | ||
Dual Fuel/ (dF) | 0 (Off) | (1 to 9) | ||
Compressor Delay (Cd) | 60 | (00 to 99 sec) | ||
O/B Output Configuration | On A/C 0 | On Heat B |
White-Rodgers is a division of Emerson Electric Co. The Emerson logo is a trademark and service mark of Emerson Electric Co
Emerson 1F95EZ-0671 Easy Reader Thermostat Owners Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…