Emerson 1F95EZ-0671 Easy Reader Thermostat
Message to Homeowners
Congratulations on choosing the Emerson Blue Easy Reader Thermostat. Blue Easy Reader is designed to be the most accessible thermostat you have ever used. This thermostat features large numbers and letters for easier viewing, and a “one button to one function” operation for total simplicity. As with all Emerson Blue thermostats, no other brand offers better temperature accuracy or reliability. Blue Easy Reader Thermostat consists of two parts, the base or wall plate mounted on your interior wall and the display and control front that snaps onto the base piece. Depending on your installation, your Blue Easy Reader may be battery-powered or system powered. Either way, it is recommended to keep fresh batteries installed. Batteries are accessible by removing the control front from the base.
Whenever “Change ” appears in the display, new premium brand AA alkaline batteries should be installed. If the house will be unoccupied for an extended period and is displayed, install new batteries before leaving. If you plan to use Blue Easy Reader as a non-programmable thermostat, please turn the page to get started. Keep in mind that Easy Reader can also be a programmable thermostat if you should change your mind later. Please call 800-284-2925 if you need assistance in adjusting to programmable. If you plan to use Easy Reader as a programmable thermostat, please skip to page 6.
BLUE EASY READER THERMOSTAT – NON-PROGRAMMABLE MODE
THERMOSTAT DISPLAY OVERVIEW
USING YOUR THERMOSTAT
- On the home, screen display select your desired system operating mode (Heat or A/C).
- Press either the or button to select the desired room temperature “setting”.
- Press the Fan button to select the desired fan operation, Auto or On.
- Press Off to turn the Heating and A/C system Off. The fan will turn Off if it is On.
If your heating or A/C system is a heat pump, the system automatically activates Auxiliary Heating when the outside temperature is too cold for the heat pump to efficiently heat the home. You can manually activate the auxiliary heating by pressing and holding the Heat button until Aux changes to Aux. To turn the manual auxiliary off press the Heat button again. Now enjoy the simple operation of your Easy Reader Non-Programmable Thermostat.
THERMOSTAT DISPLAY OVERVIEW
OTHER DISPLAY ICONS FOR PROGRAMMING
OTHER DISPLAY ICONS FOR PROGRAMMING
- Run Indicates button to press to exit any menu and return to normal operation.
- The time Indicates button used to set time and date. Press button to step through the hour, minute, Year, Month, and Date.
- Adv Day Indicates button used when programming to advance through the days of the week.
- Aux Indicates system is selected as heat pump or indicates that auxiliary heating system is operating.
- Call for Service Will display if your heating or A/C system has the diagnostic capability and needs a qualified technician to service the equipment.
- Shows time of day. When setting the Time, displays time or date. Each press of the “Time” button will change the hour, minute, Year, Month, and Date. In Sched (Schedule) mode will show start time for a period.
- In Normal operation, the current day of the week will be displayed. When setting the Time indicates the day of the week selected. In Sched mode indicates the day of the week being programmed starting with Monday. Press Adv Day button to step through the days of the week.
- In Normal operation mode indicates the current Program period “Morn, Day, Eve, or Night”. In Sched mode will indicate the period of the day being programmed
- Hold Temp Indicates the program schedule is temporarily overridden. The thermostat will maintain the current desired temperature for a two-hour period. “Hold” will be displayed when the thermostat is placed in permanent hold using the Hold button.
- The Limit Is displayed when the desired temperature is adjusted with the or keys to the
temperature limit selected in the setup menu. - Hold Copy Menu Menu indicates a button to press to access the programming and time setting functions or to enter the Configuration menu. Hold indicates the button to press to enter permanent Hold. Copy is used in programming.
- She Indicates button to press to enter Sched mode to enable setting of the program schedule. In Hold or Hold Temp mode, “Run Sched” indicates a button to press to return to Run mode.
SETUP GUIDE FOR PROGRAMMABLE OPERATING MODE
To change your thermostat to be Programmable, Item 14, Schedules per Week, in Confi guration Menu must be changed from P0 to P7. See pages 18-19, “Setting Up Your Thermostat Options.”
SET THE CURRENT TIME AND DAY
- On the Home display in Heat or A/C, press the Menu button to display additional button choices
- Press the Time button to display the hour and A or P in the clock display
- Press the or button to reach the correct hour and A (AM) or P (PM).
- Press Time to display the minutes.
- Repeat steps 3 and 4 to set minute(s), Year, Month, and day of the week.
- Press Run to return to the home screen and run the preset program that meets Energy Star guidelines.
ENERGY SAVING PRE-PROGRAM
This thermostat is set up for 7 independent da programming with 2 or 4 time/temperature periods per day. If the factory programming meets your needs, skip to page 16, using your thermostat. If you wish to change the heating or A/C schedules, please proceed to the “Programming Your Thermostat” section.
Factory Pre-Programmed schedule for the default two-period Day / Night programs
Day | Night | |||
Heating Program | 6:00 AM | 70°F | 10:00 PM | 62°F |
A/C Program | 6:00 AM | 75°F | 10:00 PM | 78°F |
Factory Pre-Programmed schedule for four periods per day, all days of the week
Wake Up (Morning) | Leave For Work (Day) | Return Home (Evening) | Go To Bed (Night) | |||||
Heating Program | 6:00 AM | 70°F | 8:00 AM | 62°F | 5:00 PM | 70°F | 10:00 PM | 62°F |
A/C Program | 6:00 AM | 75°F | 8:00 AM | 83°F | 5:00 PM | 75°F | 10:00 PM | 78°F |
HEATING AND A/C WORKSHEET
The Heating and A/C Worksheet on page 14 allow you to pencil in your own program times and temperatures. Factory settings are listed on Monday (for Monday thru Friday), Saturday and Sunday. If you are re-programming all 7 days, fill in all lines with the times and temperatures you want. Use this worksheet as a guide to reprogramming the thermostat. Keep the following guidelines in mind when planning your program.
- In Heating, lower temperatures will save energy.
- In A/C, higher temperatures will save energy.
COPY PROGRAM
When programming your thermostat, you may copy the program from one day to another day. To copy a program:
- In Sched mode, enter the program for the day.
- Press Copy. “Copy” will begin to flash and the day being copied will show.
- Press Advance Day to select the day to copy to. This day will be flashing.
- Press Copy. “Copy” will stop flashing and the day copied to will also stop flashing. The day copied from will disappear
PROGRAMMING YOUR THERMOSTAT
Fill in the blank worksheet with your desired times and temperatures:
Worksheet for Re-Programming 7-Day Program
Heating Program | Wake Up (Morning) | Leave For Work (Day) | Return Home (Evening) | Go To Bed (Night) | ||||
MON | 6:00 AM | 70°F | 8:00 AM | 62°F | 5:00 PM | 70°F | 10:00 PM | 62°F |
TUE | ||||||||
WED | ||||||||
THU | ||||||||
FRI | ||||||||
SAT | 6:00 AM | 70°F | 8:00 AM | 62°F | 5:00 PM | 70°F | 10:00 PM | 62°F |
SUN | 6:00 AM | 70°F | 8:00 AM | 62°F | 5:00 PM | 70°F | 10:00 PM | 62°F |
A/C
Program |
Wake Up
(Morning) |
Leave For Work
(Day) |
Return Home
(Evening) |
Go To Bed
(Night) |
||||
MON | 6:00 AM | 75°F | 8:00 AM | 83°F | 5:00 PM | 75°F | 10:00 PM | 78°F |
TUE | ||||||||
WED | ||||||||
THU | ||||||||
FRI | ||||||||
SAT | 6:00 AM | 75°F | 8:00 AM | 83°F | 5:00 PM | 75°F | 10:00 PM | 78°F |
SUN | 6:00 AM | 75°F | 8:00 AM | 83°F | 5:00 PM | 75°F | 10:00 PM | 78°F |
ENTER HEATING PROGRAM
- In Heat mode, press the Menu button to display additional button choices.
- Press the Sched button. The display will show the day being programmed and the time and desired temperature for the period. Either “Day” for the two-period configuration or “Morn” for four-period the configuration will be displayed to indicate the period. “Heat” is displayed indicating the mode being programmed.
- Press the Time button to toggle between Time and Temperature. Press the or buttons to adjust
the start time for the period. The time will change in 15-minute increments. - After you have set the time and the temperature for the period to begin, press Sched to advance to the next program period.
- Repeat steps 3 through 5 until all of the program times and temperatures are set for all program periods for that day.
- Use the Copy button to copy the current day’s program to any other day as described above. Or press Adv Day and repeat steps 3 through 6 until programs for all days are entered.
- When programming is complete and all of the times and temperatures match your desired heating schedule, press Run. The thermostat will now run your heating program
ENTER A/C PROGRAM
Press A/C to place the thermostat in air conditioning mode. Set the A/C program following the “Enter Heating Program” steps
USING YOUR THERMOSTAT – PROGRAMMABLE MODE
- Press Heat or A/C button to turn your system On. Press Off to turn the Heating and A/C Off. The fan will turn Off if it is On.
- Press Run or Run Sched to begin running the thermostat program
- press either the or buttons to change the desired room temperature “setting”.
- Press the Fan button to select the desired fan operation.
AUXILIARY HEATING
Programmable or Non-Programmable If your heating or A/C system is a heat pump, the system automatically activates Auxiliary Heating when the outside temperature is too cold for the heat pump to efficiently heat the home. You can manually activate the auxiliary heating by pressing and holding the Heat button until Aux changes to Aux. To turn the manual auxiliary off press the Heat button again.
TEMPORARY PROGRAM OVERRIDE
This feature will override the programmed temperature setting for a two-hour period. Press or buttons to adjust the temperature. The display will show “Hold Temp” to the left of the desired temperature. To cancel the temporary setting and return to the program, press Run. Example: If you turn up the heat during the morning program, it will be automatically lowered later, when the temporary hold period ends.
PERMANENT TEMPERATURE HOLD
The Permanent Temperature Hold feature bypasses the program and allows you to adjust the temperature manually as needed. The temperature you set in Hold will be maintained indefinitely. Press or buttons to adjust the temperature. The display will show “Hold Temp” to the left of the desired temperature. Press the Hold button to maintain the new temperature.
“Hold Temp” will change to “Hold”. To cancel the permanent hold setting at any time and return to the program, press the Run Sched button. Example: You turn up the heat during the Morning program and press the Hold button, it will remain at the new temperature until you press Run Sched or you manually adjust to another temperature.
SYSTEM DIAGNOSTICS
“Call for Service” will be displayed if your heating orB air conditioning system has the diagnostic capability and needs a qualified service technician to service the equipment. On some systems with diagnostic capability “Call for Service” will flash on the thermostat display
when a technician is needed.
CONFIGURATION MENU ITEMS
Your thermostat has several configuration items. Some of these items will be set by the installer and should not be changed. However, these settings should be recorded for future reference if the installer settings are inadvertently changed To enter the Configuration Menu, the Easy Reader thermostat must be in Heat or A/C. Press and hold the Menu button for five seconds. Once in the menu, each press of the Menu Button will step to the next menu item. Menu item options can be changed by pressing the buttons
MENU ITEM | DISPLAY (DEFAULT) | OPTIONS | COMMENTS | |
1 | System Configuration | (MS 2) | HP1, HP2, SS1 | Installer Set |
2 | Electric Heat Fan | (GAS) | ELE | Installer Set |
3 | EMR | E (On) | Off | |
4 | Heat Cycle Rate | Cr HEAT (ME) | SL, FA | SS1, MS2 only |
5 |
Heat Pump Configuration Cycle Rate | Cr Heat / A/C (ME) | SL, FA | Heat Pump HP1, HP2 only |
6 | A/C Cycle Rate | Cr A/C (ME) | SL, FA | SS1, MS2 only |
7 | Auxiliary Heat Cycle | Cr AUX Heat (FA) | SL | HP1, HP2 only |
8 | Compressor Lock-out | CL (OFF) | On | Installer Set |
9 |
System Mode Configuration | (Heat, A/C, Off) | Heat, Off, Fan / Heat, Off / A/C, Off | Installer Set |
SETTING UP YOUR THERMOSTAT OPTIONS
MENU ITEM | DISPLAY (DEFAULT) | OPTIONS | COMMENTS | |
10 | Compressor Optimization | CO (OFF) | On | Installer Set |
11 | LCD Display Light | dL (On) | Off | |
12 | Temperature Display Adj. | HI (0) | 1 to 5 Hi or LO | |
13 | oF/oC Selection | (oF) | oC | |
14 | Schedules per week | P (0) | 7 | |
15 | Periods per day | PS (2) | 4 | |
16 | Fast HEAT | HEAT FA (On) | Off | |
17 | Fast A/C | A/C FA (On) | Off | |
18 | Daylight Savings Time | dS (On) | Off | |
19 |
Temperature Range Heat Limit | HL (99) | 62-98 | |
20 | Temperature Range A/C Limit | LL (45) | 46-82 | |
21 | Dual Fuel / Electrical Fuel | dF (0) | 1-9 | HP1, HP2, Installer Set |
22 | Compressor Delay | Cd (60) | 00-99 | HP1, HP2, Installer Set |
23 | O/B Output Configuration | On A/C (O) | On Heat (B) | Installer Set |
24 | Exit Menu |
CONFIGURATION MENU DESCRIPTIONS
1 | Configuration for your Heating or A/C system | Set by installer to match your system. Record the setting. |
2 | Electric or Gas fan operation | Set by installer to match your system. Record the setting. |
3 | EMR | Energy Management Recovery (EMR) [will not appear if thermostat is set for Non-Programmable] Default setting is On. EMR starts your system early so the temperature in your home is at the desired temperature at the beginning of a program period. |
4 | Heat Cycle Rate Setting (if system is MS or SS) | Default setting is ME (medium), if you desire a longer heating cycle set to SL (Slow) or shorter cycle set to FA (Fast). |
5 | Heat Pump Cycle Rate Setting (if system is Heat Pump) | Default setting is ME (medium), if you desire a longer heat pump cycle set to SL (Slow) or shorter cycle set to FA (Fast). |
6 | A/C Cycle Rate Setting or Aux Heat Cycle Rate | Default setting is ME (medium) if you desire a longer cooling cycle set to SL (Slow) or shorter cycle set to FA (Fast). |
7 | Auxiliary Heat Cycle Rate (if system is Heat Pump) | Default setting is FA (Fast). If you desire a longer Aux heat cycle set to SL (Slow). |
8 | Compressor Lockout Protection | Set by installer to match your system. Record the setting. |
9 |
System mode configuration | Set by installer to match your system. Record the setting. |
10 |
Compressor Optimization | Set by installer to match your system. Record the setting. |
11 | Display light | The display light is defaulted on so when any button is pressed the light will illuminate the display. When set to Off, the light will not turn on. |
12 | Temperature Display Adjustment | The Easy Reader thermostat was accurately set at the factory. However, if you want to change the temperature, you can adjust the reading by plus or minus five degrees. Your thermostat displays to match your previous thermostat. |
13 | Fahrenheit or Celsius display | The Easy Reader can display temperature in either °F or °C. |
14 | Schedules Per Week | The Easy Reader thermostat is shipped from the factory as an easy to operate non-programmable thermostat (P 0). However if you want the energy saving benefits of a programmable thermostat, a seven day programming option (P 7) is available. |
15 | Periods per Schedule | If programming is selected you can choose between 2 period (Day, Night) per day or 4 period (Morning, Day, Evening, Night) per day. |
16 | Fast Heat | If your system is a multi-stage and/or Heat Pump you can select to have the additional stage of heating come on anytime the temperature setting is adjusted up by three degrees or more. If you do not desire this feature, select Off. |
17 | Fast A/C | If your system is a multi-stage Air Conditioner or multi-stage Heat Pump you can select to have the additional stage of A/C come on anytime the temperature setting is adjusted down by three degrees or more. If you do not desire this feature, select Off. |
18 | Daylight Savings Time adjustment | In Programmable mode the Easy Reader thermostat can automatically change the time in spring and fall. If you do not desire this feature select Off. |
19 | Temperature Range Heat Limit | The Easy Reader thermostat can be set to limit the highest desired temperature in heat to anywhere between 98° and 62°. |
20 | Temperature Range A/C Limit | The Easy Reader thermostat can be set to limit the lowest desired temperature in A/C to anywhere between 46° and 82°. |
21 | Dual Fuel Setting | Set by installer to match your heat pump dual fuel system. Record the setting. |
22 | Compressor Delay for Dual Fuel | Set by installer to match your heat pump dual fuel system. Record the setting. |
23 | O/B Output Configuration | Set by installer to match your heat pump system. Record the setting. |
24 | Exit | |
18 | Daylight Savings Time adjustment | In Programmable mode the Easy Reader thermostat can automatically change the time in spring and fall. If you do not desire this feature select Off. |
19 | Temperature Range Heat Limit | The Easy Reader thermostat can be set to limit the highest desired temperature in heat to anywhere between 98° and 62°. |
20 | Temperature Range A/C Limit | The Easy Reader thermostat can be set to limit the lowest desired temperature in A/C to anywhere between 46° and 82°. |
21 | Dual Fuel Setting | Set by installer to match your heat pump dual fuel system. Record the setting. |
22 | Compressor Delay for Dual Fuel | Set by installer to match your heat pump dual fuel system. Record the setting. |
23 | O/B Output Configuration | Set by installer to match your heat pump system. Record the setting. |
24 | Exit |
CONFIGURATION MENU RECORDING (Default Settings in Bold) | ||||
System Configuration | MS 2 | HP 1 | HP 2 | SS 1 |
Electric Heat Fan | Gas | Ele | ||
EMR (E) | On | Off | ||
Heat Cycle Rate (Cr Heat) | ME | SL | FA | |
Heat Pump Configuration Cycle Rate (Cr Heat A/C) | ME | SL | FA | |
A/C Cycle Rate (Cr A/C) | ME | SL | FA | |
Auxiliary Cycle Rate (Cr Heat) | FA | SL | ||
Compressor Lockout (CL) | Off | On | ||
Mode Configuration | Heat, A/C, Off | Heat, Off, Fan | Heat, Off | A/C Off |
Compressor Optimization (CO) | Off | On | ||
Display Light (dL) | On | Off | ||
Temperature Display Adjust | 0 Hi | 1 to 5 Hi | 1 to 6 Lo | |
°F/°C Selection | °F | °C | ||
Schedules per Week (P) | 0 | 7 | ||
Periods per Schedule Day (PS) | 2 | 4 | ||
Fast Heat (Heat FA) | On | Off | ||
Fast A/C (A/C FA) | On | Off | ||
Temperature Range Heat Limit (HL) | 99° | (62° to 99°) | ||
Temperature Range A/C Limit (LL) | 45° | (45° to 82°) | ||
Dual Fuel/ (dF) | 0 (Off) | (1 to 9) | ||
Compressor Delay (Cd) | 60 | (00 to 99 sec) | ||
O/B Output Configuration | On A/C 0 | On Heat B |
White-Rodgers is a division of Emerson Electric Co. The Emerson logo is a trademark and service mark of Emerson Electric Co