PLEASE NOTE: INSTALLATION MUST ONLY BE CARRIED OUT BY A QUALIFIED ELECTRICIAN OR HEATING ENGINEER.
MAKE SURE MAINS INPUT HAS A 3 AMP FUSE.
| LP241Si, LP522Si & LP722Si PROGRAMMERS LP111Si & LP711Si TIMESWITCHES | |
| Voltage | 230V a.c. +10% – 10% 50Hz |
| Programmer Rating | 2 (1) A 230V a.c. each switch |
| Timeswitch Rating | 2 (1) A 230V a.c. |
| Ambient temp | Operating: 0º to 45ºC Storage: -20ºC to 50ºC |
| Without mains power | Display: blank Time: always kept Program times: always preserved |
| Programming resolution | 1 minute |
| Wiring | Fixed wiring only, to comply with current IEE regulations |
| Maintenance | Must be maintained bya qualified electrician or heating engineer |
| Pollution degree | 2 |
| Software class | 2 |
| Ball pressure test temperature | 75ºC |
| Rated impulse voltage | 2.5kV |
Lifestyle Programmers and Timeswitches conform to the essential requirements of these Directives:
BEFORE INSTALLATION
First, make sure the mains supply is switched off!
The programmer must be set to the type of system it is to con-trol. The link on the back of the unit has two settings –Pand G.
Loosen the securing screws on the old programmer and unplug it. Check that there’s 70mm clearance to the right of the wall-plate, and 25mm above it. Check the chart on the next page to compare terminals and if necessary, change the wiring of the wall-plate to suit. Now plug the Lifestyle unit into the wall-plate and tighten the securing screws.
Check the 3A fuse, and switch on the mains.
FITTINGANEW WALL-PLATE
The ideal location is 1.4m above floor level, with reasonable lighting, good access, no condensation, no extremes of temperature, andasupporting surface that fully covers the back of the unit.
Position with 70mm clearance to the right, 25mm above, and sufficient room to access the securing screws underneath.
Fix, with terminals at the top, either direct toa flat wall using wall plugs and No. 6 x 1” (25mm) woodscrews, or on a flush mount-ing single conduit box type UA1 (BS4662) using M3.5 x 14 bolts. DO NOT USEA SURFACE MOUNTING BOX.
| TIMESWITCH TERMINAL COMPARISONS | ||||||||
| MAKE | MODEL | Earth | Neutral | Live | Common | On | Off | Spare |
| Current Mod | els | |||||||
| Drayton | Tempus 1, 2 (new models) | N | L | 1 | 2 | 3 | 4 | |
| Drayton Lifestyle | LP111, LP711, LP111Si, LP711Si | N | L | 1 | 2 | 3 | 4 | |
| Switchmaster | 300 | N | L | 4 | 1 | |||
| Discontinued/Compet | tors’ | Mod | els | |||||
| ACL | TC (Towerchron) | 2 | 1 | 4 | 7 | |||
| Drayton | SM1 | N | L | 1 | 2 | 3 | 4 | |
| Drayton | miGenie Wish 1 | N | L | 1 | 2 | 3 | 4 | |
| Drayton | MiTimeMT711R, MiTime RF Pack1 | N | L | 1 | 2 | 3 | 4 | |
| Drayton | Tempus 1, 2 (old models) | N | L | 1 | 2 | 3 | 4 | |
| Switchmaster | 980 | N | L | 4 | 1 | |||
| British Gas | EMT2, UT1, UT2 | N | L | 1 | 3 | 2 | 4 | |
| Danfoss Randall | TS15, 75 (Mk18) | E | N | L | 1 | 4 | 2 | 5/6 |
| Danfoss Randall | TS715, TS715Si | N | L | 1 | 4 | 2 | 3 | |
| Danfoss Randall | TS975 | E | N | L | 5 | 4 | 6 | 1,2,3 |
| Danfoss Randall | SET1, SET1E | E | N | L | 5 | 4 | 6 | |
| Danfoss Randall | SET4 | E | N | L | 5 | 4 | 6 | |
| Danfoss Randall | 103, 103E, 103E5, 103E7 | 4 | 5 | 6 | 3 | 1 | 2 | |
| Danfoss Randall | 911, 971 | E | N | L | 5 | 6 | 4 | 2 |
| Grasslin Towerchron | QE1 | N | L | 2 | 4 | |||
| Grasslin Towerchron | T2001, T2001Q | E | N | L | 7 | |||
| Honeywell | ST 6100A, ST 6100C | N | L | 1 | 4 | 2 | ||
| Honeywell | ST 7000B | N | L | 1 | 2 | 3 | 4 | |
| Horstmann | Centaur SC1, SC7 | L | 3 | 2 | ||||
| Horstmann | Centaur Plus, C11, C17, C17-ZW | N | L | 2 | 4 | 3 | ||
| Horstmann | Emerald 423, Pearl Auto | N | L | 2 | 4 | 3 | ||
| Horstmann | 517, Coronet, H11, H17 | E | N | L | 3 | 4 | ||
| Landis& Staefa | RWB3 | N | L | 4 | 3 | |||
| Landis& Staefa | RWB30, RWB50, 100, 152, 170 | N | L | 4 | 4 | 3 | ||
| Landis& Staefa | RWB7 | E | N | L | 2 | 4 | 3 | |
| Myson | Mictrotimer (link L-5 and 5-8) | E | N | L | 5 | 4 | 6 | |
| Myson | MEPIC | N | L | 1 | 3 | 2 | 4 | |
| Potterton Myson | EP4000, 4001, 4002, 5002 | N | L | 5 | 4 | 2 | ||
| Salus | EP101, SP120 | N | L | 4 | 3 | |||
| Sangamo | M6 | E | 4 | 6 | 3 | 1 | ||
| Smiths | Centroller Mk1, Mk2 | N | L | 3 | 2 | |||
| Smiths | Centroller 30 | 1 | 2 | 3/4 | ||||
| Smiths | Centroller 300, 980 | N | L | 4 | 1 | |||
| Sunvic | Select 107, SunProl1000 | N | L | 1 | 3 | 2 | 4 | |
| Sunvic | SP20, SP35 | N | L | 3 | 5 | 4 | 5 | |
| Venner | Vennerette | N | L | LINE | LOAD | |||
PROGRAMMER TERMINAL COMPARISONS
| PROGRAMMER TERMINAL COMPARISONS | ||||||||
| MAKE | MODEL | Earth | Neutral | Live | Ch1 on | Chl2 on | Ch3 on | Ch4 on |
| Current Models | ||||||||
| Drayton | Tempus 3, 4, 6,7 (old models), Tempus 6,7 | N | L | 1 | 2 | 3 | 4 | |
| Drayton Lifestyle | LP112, LP241, LP522, LP722 | N | L | 1 | 2 | 3 | 4 | |
| Switchmaster | 400, 600 (no connection to terminal 4 on 600) | N | L | 4 | 3 | 1 | ||
| Switchmaster | 805, 900, 900i | N | L | 4 | 2 | 3 | 1 | |
| Discontinued/Competitors’ Models | ||||||||
| ACL | MP (Towerchron) | 2 | 1 | |||||
| ACL | FP (Towerchron) | 2 | 1 | 8 | 11 | 6 | 10 | |
| Drayton | SM2 | N | L | 1 | 2 | 3 | 4 | |
| Drayton | miGenie Wish 2 | N | L | 1 | 2 | 3 | 4 | |
| Drayton | MiTime MT721R, MiTimeRF Pack 2 & 3 | N | L | 1 | 2 | 3 | 4 | |
| British Gas | EMP2, UP1, UP2 | N | L | 1 | 2 | 3 | 4 | |
| Danfoss Randall | CP15, CP715, FP15, FP715 (Mk18) | E | N | L | 1 | 2 | 3 | 4 |
| Danfoss Randall | 3020P, 3060 | E | 7 | 6 | 4 | 2 | ||
| Danfoss Randall | 4033 (link 1-6) | E | 7 | 6 | 5 | 3 | 4 | 2 |
| Danfoss Randall | 102, 102E, 102E5, 102E7 (link 6-3) | E | 5 | 6 | 1 | 2 | ||
| Danfoss Randall | 701 (link L-5 and 5-6) | E | N | L | 3 | 1 | ||
| Danfoss Randall | 702 (link L-5 and 5-6) | E | N | L | 4 | 2 | 3 | 1 |
| Danfoss Randall | 922, 972 (link L-2 and 2-5) | E | N | L | 1 | 4 | 3 | 6 |
| Danfoss Randall | SET2, SET2E, SET3E, SET3M, FP975 SET5 (link L-2 and 2-5) | E | N | L | 3 | 6 | 1 | 4 |
| Grasslin Towerchron | DP 72, QE2 | N | L | 1 | 2 | 3 | 4 | |
| Honeywell | ST 699/799 (link L-5 and 5-8) | N | L | 7 | 4 | 6 | 3 | |
| Honeywell | ST 6200, ST 6300, ST 6400, ST 6450 | N | L | 1 | 2 | 3 | 4 | |
| Honeywell | ST 7100 (link L-3 and 3-6) | N | L | 7 | 4 | 8 | 5 | |
| Horstmann | 525, 527, 425 Diadem, H21, H27, H121, Tiara (link L-2 and 2-5) | E | N | L | 3 | 6 | 1 | 4 |
| Landis& Staefa* | RWB2, RWB2E, 20, 40, 102, 200, 252 & 270, RWB9 | N | L | 1 | 2 | 3 | 4 | |
| Myson | Microtimer (link L-5 and 5-8) | N | L | 7 | 4 | 6 | 3 | |
| Myson | MEP2C | N | L | 1 | 2 | 3 | 4 | |
| Potterton Myson | All EP2000’s, EP3000’s, EP6000’s (link L-5 and N-N) | N | L | 1 | 2 | 3 | 4 | |
| Potterton Myson* | Mini Minder | N | L | 1 | 2 | 3 | 4 | |
| Salus | EP200, SP220 | N | L | 1 | 2 | 3 | 4 | |
| Sangamo | M5 (link 1-6) | N | L | 1 | 8 | |||
| Sunvic | Select 207, SunPro 2000 | N | L | 1 | 2 | 3 | 4 | |
| Sunvic | SP50, SP100 (link L-3) | N | L | 1 | 4 | 2 | 5 | |
Can simply be removed from the backplate and replaced without any disturbance to the existing wiring.
Make the wiring connections as above. Note that the output contacts are voltage-free, so power needs to be put on to Terminal 1 either by linking from Terminal L or from a separate supply with a 3A fuse.
WIRING THE PROGRAMMER
USING A DRAYTON SIMP-L-FIT, ALTHOUGH NOT NECESSARY, WILL MAKE THIS INSTALLATION EASIER.
Drayton LP522 Weekend programmer Thermostat User Instruction
Drayton LP522 Weekend programmer Thermostat Installation Instruction
Skip to PDF contentFree Money Online Casino No Deposit Canada However, and players have no control over it.…
Eureka Casino No Deposit Bonus Codes For Free Spins 2026 Furthermore, and beginner-friendly as well.…
Top 10 Online Canada Casinos Top 10 online canada casinos you can contact Easy Slots'…
2026 Canada Changes In Blackjack 2026 canada changes in blackjack an online casino reload bonus…
Mannheim Casino No Deposit Bonus Codes For Free Spins 2026 Don't miss out on this…
Slot Games For Real Money I should start with a variety of gambling options, you…