If you do not have the knowledge to install the SCR safely then you must arrange for a competent electrician to install it for you. Wiring must conform to the current IEE wiring regulations.
Prior to commencing the installation you must ensure the mains supply is switched off.
Installation Instructions
Read all installation and commissioning instructions before proceeding. Do not switch on until ready to commission.
The system wiring must be able to be fully disconnected from the mains supply by a switch incorporated in the fixed wiring having a contact separation of at least 3mm on both poles. Fused at 3A.
The Digistat+C SCR (receiver) should be mounted in a convenient position, close to the boiler or central heating system wiring centre. (Care should be taken not to mount the SCR in a position where it is surrounded by metal objects or mains voltage cable, as this may interfere with the radio signal).
For the best performance install in an open space, at least 30cm
distance from any metal objects including wall boxes and boiler housing. It is recommended that the SCR is mounted on the wall nearest the fina I location of the Digistat+C RF thermostat and not less than 30cm from the boiler side panel.
Warning: Installing the SCR too close to the metal side panel or main cables may interfere with the radio signal.
SCR wallplate clearances
This product is double insulated and does not require an earth connection. The SCR should be wired to the combi boiler or central heating wiring using the correct type of cable or flex. The SCR should be wired in to replace hard wired room or programmable thermostats shown on the system or boiler wiring diagrams. Always check other manufacturers’ instructions for compatibility.
DHW Cylinder Thermostat
IMPORTANT: MULTIZONE INSTALLATIONS ONLY If more than one ‘wireless system’ is fitted within the same property. e. for controlling 2 or more zones (multi-zone) it Is essential that the Digistat RF units are matched correctly to the relevant SCR. This is easily achieved by commissioning each Digistat and SCR in turn.
During normal operation, the red LED on the SCR will flash for 7 seconds each time a radio signal is received from the Digistat RF. This will occur approximately every 5 minutes. The green LED on the SCR denotes a call for heat (ON). Once the system has been successfully commissioned, buttons 1 and 2 on the SCR should not be pressed simultaneously, unless a replacement Digistat RF or SCR is fitted.
To assist with commissioning or checking the system operation, there is a positive OFF setting outside the temperature scale on the cylinder thermostat. First adjust the minimum temperature setting to 40C as described in the user guide, then rotate the dial fully anticlockwise for OFF.
Download Manual
Drayton Digistat +CRF 13616 Cylinder Thermostat Installation Guide
Other manuals:
Drayton Digistat +CRF 13616 Cylinder Thermostat USER Guide
Drayton Digistat +CRF 13616 Cylinder Thermostat Product Specifications Guide
Drayton Digistat +CRF 13616 Cylinder Thermostat Installation Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…