Since the temperature measurement sensor is inside the box, you must install the thermostat:
Press
Output number | 1 to 16 depending on the system. | ||
| Transmitter type | 0 | Underfloor heating (by default) |
1 | Heater | ||
Heating percentage limitation | From 10 to 100% in increments of 10 (100%= No limitation, by default). |
Master thermostat | Zone thermostat | |
Temperature management | Controlled zone | Controlled zone |
On/Off management | All zones | Controlled zone |
HEAT/COOL mode management | All zones | – |
Correction of the measured temperature | +/- 5°C in increments of 0.1°C (0°C by default) | ||
Temperature displayed in normal mode | 0 | Setting display (default selection) | |
1 | Display of the measured temperature. | ||
| Ban on the Cool regulation on the Thermostat’s thermal zones (if SW2 = ON on the technical unit) | 0 | No ban (default selection) |
1 | Ban | ||
Display the status (ON) of the associated output | 0 | No (default selection) | |
1 | Yes | ||
Thermostat type | 0 | Zone thermostat (default selection) | |
1 | Master thermostat |
Activation of the door/window magnetic contact function (the room thermostat switches to Frost Protection mode if the door/window magnetic contact is activated). | 0 | Not activated | |
1 | Active (default selection) – Display of the | ||
This menu is only available if CF06 = 1. The | 0 | Not flashing | |
1 | Flashes in case of detection (default selection) | ||
‘Presence detection’ function (the thermostat setting is lowered if no presence is detected). | 0 | Not activated | |
1 | Activated (default selection) | ||
| Displays the time and date in the 12h/24h format | 0 | 12h (AM/PM) |
1 | 24h (default selection) | ||
| Standby mode | 0 | Display off after a 10-second time-out period |
1 | Display illuminated continuously (default selection) | ||
2 | Display off (10-second time-out period) from 23.00 to 6.00. Display on from 6.00 to 23.00. | ||
| Backlighting | 0 | Deactivated |
1 | When activated, it goes out after a 5-second time-out period(default) | ||
Output number | 1 to 16 depending on the system. ‘–‘ is displayed if none are allocated. | ||
| Transmitter type | 0 | Underfloor heating (by default) |
1 | Heater | ||
Heating percentage limitation | From 10 to 100% in increments of 10 (100%= No limitation, by default). |
Press
You can decide not to use the calendar function (no automatic changeover between summer and winter). In this case, when you select the year, select by pressing on.
INITIALISING THE THERMOSTAT PARAMETERS
This menu restores the system to factory settings.
The system automatically returns to STOP mode.
DELETING OF THE THERMOSTAT WITH THE WIRELESS GATEWAY
Press or turn the selector knob to exit the active mode.
If the display does not return to 00, this means that some products are not responding. To delete them, start again with Ln04(3).
When a defect is detected on the system, the symbol
Press ‘i’ to display the type of defect.
Error messages
| Address error. Several products were assigned to the same output (CF20). |
| Thermostat internal sensor shorted |
| Thermostat internal sensor cut off |
| Error on the outdoor sensor associated with the thermostat channel |
Download Manual:
Delta Dore 8000-TAP-RF Wireless Programmable Thermostat Instruction Manual
Delta Dore 8000-TAP-RF Wireless Programmable Thermostat Instruction Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…