Since the temperature measurement sensor is inside the unit, you must install the thermostat flush-mounting box:
IMPORTANT: Do not install the thermostat on a wall in contact with the outdoors or with an unheated room (e.g. garage, etc.)
The sleeve output in the flush-mounting box must be blanked off (with mastic) in order to avoid unwanted air movements that would cause the sensor reading to be inaccurate.
CF05: the Master thermostat enables the centralised use of ON/OFF and HEAT/COOL (at least one Master thermostat is required in an installation without a programmer).
| Temperature management | On/Off management | HEAT/ COOL mode management | |
| Master thermostat | On the controlled zone | On all zones | On all zones |
| Zone thermostat | On the controlled zone | On the controlled zone | – |
| Correction of the measured temperature | +/- 5°C in 0.1°C increments (0°C by default) | ||
| Temperature displayed in normal mode | 0 | Setting display (default selection) | |
| 1 | Display of the measured temperature. | ||
| | Ban on the Cool regulation on the thermal zones of the Room Temperature (if SW2 = ON) | 0 | No ban (default selection) |
| 1 | Ban | ||
| Display the status (ON) of the associated output | 0 | No (default selection) | |
| 1 | Yes | ||
| Thermostat type | 0 | Zone thermostat (default selection) |
| 1 | Master thermostat | ||
| Activation of the window/door magnetic contact function (the room thermostat switches to Frost Protection mode if the window/door magnetic contact is activated). | 0 | Not activated | |
| 1 | Activated (default selection) | ||
| ‘Presence detection’ function (the thermostat lowers its setting in the event that no presence is detected). | 0 | Not activated | |
| 1 | Activated (default selection) | ||
| Standby mode | 0 | Display off after a 10 seconds time-out period | |
| 1 | Display illuminated continuously (default selection) | ||
| Backlighting | 0 | Deactivated | |
| 1 | When activated, it goes out after a 5-second time-out period (default) | ||
| Output number | 1 to 16 depending on the system. ‘–‘ is displayed if none are allocated. | ||
| Transmitter type | 0 | Underfloor heating (by default) | |
| 1 | Heater | ||
| 2 | Ceiling or ductable | ||
| Heating percentage limitation | From 10 to 100% in increments of 10 (100%= No limitation, by default). | ||
DELETING ALL THE ASSOCIATION BUS WITH THE TECHNICAL UNIT
DELETING THE ASSOCIATION OF THE THERMOSTAT WITH THE TECHNICAL UNIT
Press OK to open the setting, then press + and – to select «= –». Confirm with OK.
INITIALISING THE ROOM THERMOSTAT SETTINGS
This menu restores the system to factory settings.
The system automatically returns to OFF mode.
Download Manual:
Delta Dore 8000-TA-BUS Zone Thermostat Installation Instructions
Delta Dore 8000-TA-BUS Zone Thermostat Installation Instructions
Free Money Online Casino No Deposit Canada However, and players have no control over it.…
Eureka Casino No Deposit Bonus Codes For Free Spins 2026 Furthermore, and beginner-friendly as well.…
Top 10 Online Canada Casinos Top 10 online canada casinos you can contact Easy Slots'…
2026 Canada Changes In Blackjack 2026 canada changes in blackjack an online casino reload bonus…
Mannheim Casino No Deposit Bonus Codes For Free Spins 2026 Don't miss out on this…
Slot Games For Real Money I should start with a variety of gambling options, you…