new sleek design, intuitive control, & easy to install process. Benefits Include:
Supply: | 120-240 VAC, 50/60 Hz |
Max. Load: | 15A maximum (resistive load) |
Power: | 1800W at 120 VAC / 3120W at 208 VAC / 3600W at 240 VAC |
GFCI: | Class A (5 mA trip level) |
Temperature Range: | 41°F to 104°F (5°C to 40°C) |
Floor Limit Range: | 41°F to 104°F (5°C to 40°C) |
Ambient Temp. Range: | 32°F to 104°F (0°C to 40°C) |
On/Off Differential: | 0.7°F (0.4°C) |
Regulation Principle: | PWM / PI |
Housing: | NEMA 1 (IP20) |
Floor Sensor Type: | NTC (10 KΩ) 15 ft. (4.5 m) |
Dimensions (HxWxD): | 5.1” x 3.2” x 0.8” (130mm x 82mm x 20mm) |
Wall box (HxWxD): | 3”x2”x2” (76mm x 51mm x 51mm |
Display: | 3.5” (89mm), 65k color |
Touch: | resistive |
Programmable events: | 1-6 event per day |
Features: | Child lock |
Control Modes: | Ambient temp. w/ floor protection, Floor temp. w/ floor protection, Ambient temp. w/o floor protection (regulator mode without sensor) |
Typical Application
Part No. | Description |
088L5136 | LX205T Programmable Touch Thermostat |
Applications
Products in this data sheet are for use with these Danfoss mats and cables:
Danfoss Electric Heating Products |
LX Electric Floor Heating Mats and Cables |
TX-FH Floor Heating Cables |
TX-SH Storage Heating Cables |
Part No. | Description |
088L5135 | Power Module with GFCI (15 Max. Amps) |
088L3450 | Single Contactor, 3P, 600V Max (120V Max Amps, 120V Coil Voltage) |
088L3451 | Single Contactor, 3P600V Max (120V Max Amps, 208V-240V Coil Voltage) |
ETF-110/99C | Replacement Thin Floor Sensor (10K Ω) |
Danfoss offers a two-year limited warranty covering defects in workmanship and materials.
Technical Services
For technical questions, please contact Danfoss Heating Division North America at 1-866-676-8062. More information on Danfoss Electric Heating products is available at www.LX.Danfoss.com.
Danfoss can accept no responsibility for possible errors in catalogs, brochures, other printed materials, and website information. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alteration can be made without subsequent changes being necessary in specifications already agreed upon. All trademarks in this material are the property of the respective companies. Danfoss and Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
Danfoss
Toll Free: 1-866-676-8062 Fax: 416-352-5981 www.LX.Danfoss.com TEL: 866-676-8062, FAX: 416-352-5981 2
DOWNLOAD MANUALS:
DANFOSS LX205T TOUCH SCREEN PROGRAMMABLE THERMOSTAT Product Specifications Guide
OTHER MANUALS:
DANFOSS LX205T TOUCH SCREEN PROGRAMMABLE THERMOSTAT Installational Manual
DANFOSS LX205T TOUCH SCREEN PROGRAMMABLE THERMOSTAT Quick Start Guide
DANFOSS LX205T TOUCH SCREEN PROGRAMMABLE THERMOSTAT Product Specifications Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…