Danfoss ECtemp Next Plus Electronic Thermostat

Introduction

The Danfoss ECtemp Next Plus is an electronic programmable timer thermostat used for controlling electrical floor heating elements. The thermostat is designed for fixed installation only and can be used for both direct heatings of the entire room and for comfort heating of the floor.

Technical Specifications

Operation voltage 85-250V~, 50/60 Hz
Standby power consumption 0,4 W
Relay: Resistive load Inductive load

Max. 16 A / 3680 W @ 230 V

cos φ= 0.3 Max. 1 A

Floor sensor Floor Sensor NTC 10 kΩ at 25°C

Room Sensor NTC 10 kΩ at 25°C

Sensing values: (Default NTC 15 K) 0°C

20°C

50°C

 

42 kΩ

18 kΩ

6 kΩ

Control Hysteresis ± 1.0° C
Ambient temperature -10°C to +60°C
Frost protection temperature 5°C to +9°C (default 5°C)
Temperature range Room temperature: 5-35°C. Floor temperature: Max. 35°C is default.
Sensor failure monitoring The thermostat has a built-in monitoring circuit, which will switch off the heating if the sensor is disconnected or short-circuited
Cable specification max. 1×4 mm2 or 2×2,5 mm2
Ball pressure test temperature 75°C
Pollution degree 2 (domestic use)
Controller type 1C
Software class A
Storage temperature -20°C to +65°C
IP class 30
Protection class Class II –
Dimensions 86 x 86 x 16/40.5 mm (in-wall depth: 24.5 mm)
Weight 103 g

Safety Instructions

  • Make sure the mains supply to the thermostat is turned off before installation.
  • Important: When the thermostat is used to control a floor heating element in connection with a wooden floor or similar material, always use a floor sensor and never set the maximum floor temperature to more than 35°C

Please also note the following:

  • The installation of the thermostat must be done by an authorized and qualified installer according to local regulations.
  • The thermostat must be connected to a power supply via an all-pole disconnection switch.
  • Always connect the thermostat to the continuous power supply.
  • Do not expose the thermostat to moisture, water, dust, and excessive heat.

Mounting Instructions

  • Place the thermostat at a suitable height on the wall (typically 80-170cm.).
  • The thermostat should not be placed in wet rooms.
  • Place it in an adjacent room and use floor sensor only. Always place the thermostat according to local regulation on IP classes and use floor sensor only.
  • Do not place the thermostat on the inner side of an exterior wall.
  • Always install the thermostat at least 50 cm. from windows and doors.
  • Do not place the thermostat in a way that it will be exposed to direct sunlight.
  • Note: A floor sensor enables a more accurate temperature control and is recommended in all floor heating applications and mandatory under wooden floors to reduce the risk of over-heating the floor
  • Place the floor sensor in a conduit in an appropriate place where it is not exposed to sunlight or draft from door openings.
  • Equally distant and >2cm from two heating cables.
  • The conduit should be flush with the floor surface – countersink the conduit if necessary.
  • Route the conduit to the connection box.
  • The bending radius of the conduit must be min 50mm

Connect the thermostat according to the connection diagram.

Symbols

Settings

Power ON/OFF
Switch thermostat ON/OFF by pressing button on top of thermostat.

Initial Settings

  • Initial settings must be specified when the unit is activated for the first time:
  • Press M button for 6 seconds to enter the parameter setting mode.
  • The upper digits indicate the parameter number.
  • Press M for parameter selection.
  • Press < or > to set the parameter range.
  • Complete all adjustments.
  • Press to exit ECtemp Next Plus settings, which is available for this purpose.
  • To exit ECtemp Next settings automatic wait approx. 30 seconds.

The digits indicate the set value as follows:

No Parameter settings Settings range Default
P01 Working mode 01: Manual

02: Advanced Program- mable Timer

02
P02 Temperature control mode 01: Room and floor temp; 02: Only floor temp.;

03: Only room temp.*

01
P03 Maximum floor temperature 20-30˚C (only for 01 in P02)** 35˚C
P04 Frost protection 01: Enable; 02: Disable 01
P05 Frost protection setpoint 5-9˚C 5˚C
P06 Timer display option 01: 24h; 02 12h 01
P07 Room temp. display option at shutdown 01: No display surrent temp.;

02: Display current temp.

01

Advanced Programmable Timer

The Advanced Programmable Timer mode enables the setting of a timer-controlled program for automatic comfort temperature, and an energy-saving lower setback temperature if standard room comfort temperature is not required. The function consists of 2 programs:

P1 with 4 events in 5 days (Mon. Tue. Wed. Thu. Fri

  • P1: Press and hold to display
  • Mo. Tu. We. Th. Fr.

P1, Event 1:

  • Use < or > to select the start time.
  • Press to accept the setting.
  • Use < or > to select the temperature.
  • Press to accept the setting.

P1, Event 2-4:

  • Repeat the Event 1 procedure for programming Event 2-4.

P2 with 4 events in 2 days (Sat. Sun.).

  • P2: Sa. Su. are now shown in the display.

P2, Event 1:

  • Use < or > to select the start time.
  • Press to accept the setting.
  • Use < or > to select the temperature.
  • Press to accept the setting.

P2, Event 2-4:

  • Repeat the Event 1 procedure for programming Event 2-4.

The thermostat will continue the 4-event program based on the present time and day. To set and change the room temperature temporarily:

  • Press < or > at any time to change the desired temperature value. SET is shown in the display.
  • When releasing the < or >, the display returns to showing the actual temperature. This temperature change is only temporary and will be maintained only until the next programmed setting
  • A default program provides timer control if the customer does not create own programs

Days

Event 1 Event 2 Event 3 Event 4
Start time Temp Start time Temp Start time Temp Start time Temp
Mon – Fri. 6:30 20˚C

(27˚C)*

8:30 15˚C

(25˚C)*

16:30 20˚C

(27˚C)*

22:30 25˚C

(25˚C)*

Sat – Sun. 7:30 20˚C

(27˚C)*

9:30 20˚C

(27˚C)*

16:30 21˚C

(28˚C)*

22:30 25˚C

(25˚C)*

Temperature Setting

  • Changing of desired temperature – press < or >.
  • SET is showed in the display.
  • Adjustment is changed in steps of 0.5°C
  • When releasing < or > again the display returns to normal mode and shows actual temperature.
  • It will be possible to set the maximum floor temperature up to 45°C.
  • It would also be possible to use only one temperature sensor. However, this option is not recommendable as this cause an increased risk of overheating of the floor.
  • Extending maximum floor temperature and Setting into room only mode – See point 4.9 and 4.10.

IMPORTANT: When the thermostat is used to control a floor heating element in connection with a wooden floor or similar material, always use a floor sensor and never set the maximum floor temperature to more than 35 ° C.

Thermal resistance [m2K/W] Examples of Flooring Details The approximate setting for 25˚C floor temperature
0.05 8 mm HDF based laminate >800 kg/m3 28˚C
0.10 14 mm beech parquet 650 – 800

kg/m3

31˚C
0.13 22 mm solid oak plank >800 kg/m3 32˚C
< 0.17 Max. carpet thickness suitable for floor heating acc. to EN 1307 34˚C
0.18 22 mm solid for planks 450 – 650

kg/m3

35˚C

Timer Setting

  • To adjust time and weekday – press
  • Use < or > to adjust hours,
  • Press again to shift to minutes and use < or > for adjusting3
  • Press again to shift to weekdays and use < or > for selecting right day
  • Finish timer setting by pressing any other button or wait for automatic exit after 6 sec. without operation

Safety Lock

  • Press M and > simultaneous to enable Safety lock.
  • To release the safety lock press M and > simultaneous again.

Away Mode

  • Press M to get into Away mode is showed in the display
  • Changing the desired temperature in Away mode
  • Press < or >.
  • SET is showed in the display
  • Adjustment in steps of 0.5°C
  • Press M to exit Away mode again

Present Floor Temperature

  • Press M and hold – Press < within 6 sec also start to flash and current floor temperature is being displayed.
  • Press any other button to exit or wait for automatic exit after 6 sec. without operation

Change to Room control only

Switch Power OFF

  • Press M and Timer buttons simultaneously for approx. 10 seconds
  • Select Function P08: Only Room temperature control
  • Select Setting 01: Enable

Switch Power ON

  • Press M button for approx. 6 seconds
  • Select Parameter Setting P02: Temperature Control mode
  • Select Setting Range 03: Room Only mode

Extending Maximum floor temperature limitation to 45°C

Power OFF

  • Press M and Timer buttons simultaneously for 10 seconds into those parameters setting.
  • Select Function P07 (Table in 4.11): Setting range extension for P06, P07 and P08
  • Select Setting 02: Maximum 45°C
  • Adjust Maximum Floor temperature according to need up to 45°C

Power ON
Press M button for 6 seconds Select P03 (Table in 4.2): raise floor temperature limitation higher than 35°C by using the >

Table for 4.9 Change to Room control only and 4.10 Extending Maximum Floor temperature limitations to 45°C

No. Function Setting Factory default
Danfoss ECtemp™ Next Plus
P01 Room Sensor Calibration Offset:-10˚C to

+10˚C

0˚C
P02 Floor Sensor Calibration Offset:-10˚C to

+10˚C

0˚C
P03 Maximum Room Temp. Limitation 5-35˚C(Active in Temperature Control Mode 01)

35˚C

P04 Minimum Room Temp. Limitation 5-35˚C(Active in Temperature Control Mode 01)

5˚C

P05 Maximum Room Temp. Limitation 5-35˚C(Active in Temperature Control Mode 02)

35˚C

P06 Minimum Room Temp. Limitation 5-35˚C(Active in Temperature Control Mode 02)

5˚C

P07 Setting range extension for P06, P07, P08 01: Max. 35˚C, 02:

Max. 45˚C

01

P08 Only room temperature control 01: Enable, 02: Disable

02

Error Codes

E1 Room sensor failure
E2 Floor sensor failure
EE EEPROM failure
Lo Temperature lower than 0˚C
Hi Temperature higher than 5˚C

Warranty

5 year warranty

Disposal Instruction

Reference

Download Manual:

Danfoss ECtemp Next Plus Electronic Thermostat Installational Guide

OTHER MANUALS:

Danfoss ECtemp Next Plus Electronic Thermostat Product Specifications Guide

Danfoss ECtemp Next Plus Electronic Thermostat Installational Guide

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

1 year ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

1 year ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

1 year ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

1 year ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

1 year ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

1 year ago