Danfoss

Danfoss CET2000B-RF Wireless Cylinder Thermostat Data Sheet

Danfoss CET2000B-RF Wireless Cylinder Thermostat

Features

The CET 2000B-RF is a battery-powered RF cylinder thermostat that measures cylinder temperature using a strap-on cylinder temperature sensor.
The sensor is fitted to the cylinder wall and wires directly to the thermostat, which is normally located adjacent to the cylinder. The clamp-on sensor comes complete with a spacer piece to enable installation with most thicknesses of cylinder insulation (25-55mm).
A receiver unit is mounted next to the boiler or zone valve and responds to commands issued by the thermostat over a secure wireless connection. This avoids the need for wiring between the thermostat and boiler or zone valve, reducing installation time and cabling.
This arrangement is perfectly suited for new installations where furnishings prohibit running recessed or surface-mounted cabling, and in existing installations where the cylinder is being moved or replaced.
The CET2000B-RF includes a large easy-to-read LCD display which is backlit for viewing in dimly lit locations.
Hot water temperature adjustment is made by simple up/down buttons and the digital display allows accurate settings. In normal operation, the display will show the cylinder temperature, when the buttons are pressed, the display changes and flashes the set temperature required.
A flame icon is displayed whenever the thermostat is calling for hot water demand and an aerial icon confirms that the thermostat is connected to the receiver.The Thermostat can be placed in standby mode where hot water isn’t required for prolonged periods or where tampering is an issue the set temperature can be locked, both modes indicated by icons on the display.
The display also gives an indication when the batteries need replacing and should there be an issue with the cylinder sensor error codes are shown.

Specifications

Thermostat Specifications

Wireless Cylinder Thermostat CET 2000B-RF
Code no. (including RX1-S single channel receiver) 087N727900
Temperature range 40-65°C
Clamp-on temperature sensor
Operating frequency 433.92 MHz <1mW ERP
Maximum range 30 metres
Power supply 2 x AA alkaline batteries
Maximum ambient temperature 45°C
IP Rating IP20
Dimensions, setting module (mm) 84 wide x 84 high x 35 deep
Dimensions, clamp-on sensor (mm) (2) 49 wide x 49 high x 45 (or 79) deep
(1) Ensure no large metal objects are between thermostat and receiver as these will interfere with radio signal.

(2) 79mm depth is with spacer for use with high insulation cylinder.

Receiver Specifications

Receiver Features RX1-S
Type Single Channel Receiver
Power supply (receivers) 230 Vac, 50/60 Hz
Contact details 1 x SPDT
Output Volt Free
Contact rating 3A (1) at 230 Vac
IP Rating IP40
Dimensions (mm) 84 wide x 84 high x 28 deep

Wiring Diagrams

Wireless Heating and Hot Water Control, using 2 x 2 Port Valves

Hard Wired Heating with Wireless Hot Water Control, 2 x 2 Port Valves

Wireless Heating and Hot Water Control, with 3 Port Mid Position Valve

Hard Wired Heating with Wireless Hot Water Control, 3 Port Mid-Position Valve

Danfoss can accept no responsibility for possible errors in catalogs, brochures, and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed.
All trademarks in this material are the property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
Danfoss Ltd.
Ampthill Road Bedford MK42 9ER
Tel: 01234 364621
Fax: 01234 219705
Email: ukheating@danfoss.com
Website: www.heating.danfoss.co.uk

REFERENCE

Download Manual

Danfoss CET2000B-RF Wireless Cylinder Thermostat Data Sheet

OTHER MANUALS

Danfoss CET2000B-RF Wireless Cylinder Thermostat User Guide

Danfoss CET2000B-RF Wireless Cylinder Thermostat Installation Guide

Danfoss CET2000B-RF Wireless Cylinder Thermostat Data Sheet

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

1 year ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

1 year ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

1 year ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

1 year ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

1 year ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

1 year ago