| CET2000B-RF | RX1-S | |
| Operating Voltage | 2.5 – 3 VDC (2xAA alkaline batteries) | 230Vac 50Hz |
| Output Relay | – | 1 x SPDT Type 1B |
| Switch rating | – | 3A (1) at 230Vac |
| Output | – | Volt free |
| Setting temp. range | 40-65°C | – |
| Maximum ambient temp. | 0-45°C | |
| Battery lifetime | 2 years | – |
| Max. range | 30 metres | |
| Operating frequency | 433.92MHz <1mW ERP | |
| IP Rating | IP20 | IP40 |
| Control | On-Off | |
| Operating mode | Domestic Hot Water Heating | |
| Construction | EN 60730-2-9 | EN 60730-1 |
| Control pollution situation | Degree 2 | |
| Rated impulse voltage | – | 2.5kV |
| Ball pressure test | 75°C | |
| Dimensions | H84 x W84 x D35 | H84 x W84 x D28 |
| Software classification | A | |
Important note RF products: Ensure that there are no large metal objects, such as boiler cases or other large appliances, in line of sight between the transmitter and receiver as these will prevent communication between thermostat and receiver.
This product should only be installed by a qualified electrician or competent heating installer, and must be in accordance with local wiring regulations.
Cable specification: minimum cross section 0.5mm2
Please Note: This product should only be installed by a qualified electrician or competent heating installer, and must be in accordance with local wiring regulations.
Mounting – CET2000B-RF
Slide the DIL switches to the settings required
To avoid unwanted tampering of the required hot water temperature the CET2000B-RF includes a key lock feature which disables the Λ and V buttons. First set the required hot water temperature using the Λ or V button. Then slide internal DIL switch 4 to the locked position and mount the CET2000B-RF back on its wallplate (as shown on page 9).
If the thermostat CET2000B-RF and receiver RX1-S have been supplied together in a combined pack, the units have been paired in the factory and no commissioning is required. If the thermostat and receiver have been supplied separately follow the steps below to pair the devices.
Danfoss Ltd Ampthill Road Bedford MK42 9ER
Tel: 01234 364621
Fax: 01234 219705
Email: ukheating@danfoss.com
Website: www.heating.danfoss.co.uk
Download Manual
Danfoss CET2000B-RF Wireless Cylinder Thermostat Installation Guide
OTHER MANUALS
Danfoss CET2000B-RF Wireless Cylinder Thermostat User Guide
Danfoss CET2000B-RF Wireless Cylinder Thermostat Data Sheet
Danfoss CET2000B-RF Wireless Cylinder Thermostat Installation Guide
Bremerhaven Casino No Deposit Bonus Codes For Free Spins 2026 The customer support team isnt…
Legal Casino Online You must provide a mailing address and social security digits to complete…
Real Cash Online Casino United Kingdom Mega Fortune is also a bit unusual in the…
Amex Casino United Kingdom Instead of free spins, you do well and have winnings that…
Best Online Casino For Roulette Time and Again is an HTML5 title, best online casino…
Fastest Payout Online Casinos Bally Wulff is known for their amazing classic slots and Back…