Product Summary

This new design heating thermostat aims at market demand, it has large LCD display. Easy operation, complete functions .It can be control motorized ball valve, motorized valve, thermal valve, solenoid valve, heater, electric heating film, electric heating carbon crystal. It is used for floor heating.

Technical Data

  • Power Supply: AC200-240V, 50/60HZ (can customize I I OV,24V, I 2V )
  • Load Current: 3A(Water Heating): 16A(Electri·· Heati􀇁:;)
  • Accuracy: ± I °C
  • Set-point Temperature Range: 5°C – 35°C
  • Limit Temperature Range: 5-99’C
  • Consumption: <I .OW
  • Temperature Sensor:NTC

Features

  • Large LCD touch screen with blue backlight display and double temperature display mode
  • Time display (minutes, hours, weeks)
  • 6-period programmable controlling temperature setting
  • Internal and external temperature sensors for choice
  • Room temperature display precision is 0.5, inner precision is 0. I
  • Setting temperature meets user’s demand for room temperature
  • Memory function when power failure, protect your setting from power failure
  • Room temperature automatically calibration function

Button Description

Function and Display

Operation Diagram

Time and Time Interval Setting

  1. Time setting
    Press time key””, time zone display minute, hour, week, press key”” or”“to adjust time.
  2. Time interval temperature auto control setting
    First step, select the time interval first, press “” screen display “LooP” (cycle control), then press ““,screcn display”l2345″(Monday to Friday control mode); press “” for 2 limes, screen display”12345″(Monday to Saturday control mode): press “” 3 times, screen displays”l 2345- !zl”(Monday to Sunday control mode); Second step, time interval time and temperature setting, when sc.,een display “(2345″or”l2345’orl2345, fzl”,press ““enter into time interval temperature setting, press “” enter into time interval time setting, press”A “or “V°'” to adjust and save automatically.
    Note: when auto control ““will disappear, if need re-set temperature when auto control, can press ““or “” 10 adjust.
  3. Modify interval time control setting
    Press”” first, then press ”“switch to the time option •.o modify time of time interval.

Time Interval Programming

Press menu key”“.can enter into time interval setting, then press time key ““can enter into interval time setting.

  1. The factory default temperature value of time interval 3 and 4 are the same as period 2,please modify default temperature when it’s necessary.
  2. Setting temperature is”00″, this time interval is shutdown.
  3. View out temperature value (floor temperature)
    1. Touch screen version: when internal control temperature and external limit temperature(high-temperature protection), under power on state, press time key not move first, then press on/off key together to switch and view external temperature (this time measure temperature display zone displays OUT TEMP temperature value),press time key to display room temperature;

Advanced Setting(suggestion: operated by technician
Tum off the thermostat, first press C9 not move, then press C) together enter into the advanced setting, it will save after the backlight isout, oress rv:, to set next data

Note: hysteresis (return temperature) description: the factory default of external sensor limit temperature(OSV) set as 42 “C,external sensor limit temperarure hys teresis(drF) set as 2.when temperature up to 44″C, relay stop output, when temperaturedrops to 40″C ~relay output a ain and heating. operation when roon, tern erature lower than setting tern crature.

Sensor fault hint

Please select the internal, and external sensor working modes correctly. If it is chosen wrong or the sensor is faulty (breakdown), the LCD interface will display “Err” ,temperature controller stops heating until the fault is eliminated. Special Hint: installation cable Please select: water heating selects 1.5-2.5mm2 rigid line; electric heating select above 2.5mm2 ri!\id line.

Power wiring diagram

Installation

Warning: please wiring right strictly according to the wiring diagram, do not make water, mud and other debris intothe thermostat, otherwise it will cause thermostat damage!

REFERENCE:

DOWNLOAD MANUALS:

Cn-hysen HY312WE Touch Screen Thermostat User Manual

Cn-hysen HY312WE Touch Screen Thermostat User Manual

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

1 year ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

1 year ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

1 year ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

1 year ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

1 year ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

1 year ago