Warning For installation by experienced service technicians only.
Caution Possible electric shock or damage to equipment can occur. Disconnect power before beginning the installation
This thermostat requires 24 Volt AC Power or 2 properly installed “AA” Alkaline batteries for proper operation. When connecting 24 Volt AC Power, the batteries may be installed as a backup. For use only as described in this manual. Any other use will void the warranty This manual is for Installer use only – do not leave it with the end user.
This thermostat is compatible with:
Electrical and Control Specifications
Terminations
Warning Disconnect power before beginning installation.
Thermostat Location
Install the thermostat approximately 5 feet (1.5m) above the floor in an area that has a good amount of air circulation and maintains an average room temperature. Avoid installation in locations where the thermostat can be affected by drafts, dead air spots, hot or cold air ducts, sunlight, appliances, concealed pipes, chimneys, and outside walls
Install the Sub-Base
Provide Power
Set Installer Switches
The Installer switches are located on the back of the thermostat and must be properly configured for this thermostat to operate properly.
Attach to Thermostat Sub-Base
Once you complete the wiring in Section 3, attach the thermostat to the sub-base and then configure the Installer Settings in Section 5.
NOTE: This thermostat ships configured as a conventional (CONV) thermostat.
Conventional and Heat Pump Systems – Typical Wiring Configurations
NOTE: Make sure installer system selection switch is properly set to CONV or HP. See Section 2. | CONVENTIONAL | HEAT PUMP | ||||
1030 / 1230 | 1230 | 1030 / 1230 | 1230 | |||
Wiring Terminal | Terminal Description | Heat Only or Millivolt | 1 Heat/ 1 Cool | 2 Heat/ 1 Cool | 1 Heat/ 1 Cool | 2 Heat/1 Cool (w/Aux Heat) |
Rh | 24 VAC Heating Transformer | Rh | Rh1 | Rh1 | Rh6 | Rh6 |
Rc | 24 VAC Cooling Transformer | – | Rc1,2 | Rc1,2 | – | – |
W1/E | (W1) Conventional Heat Relay (E*) Emergency Heat Relay | W1 | W1 | W1 | – | E7 |
W2* | 2nd Stage Heat/Auxiliary Heat | – | – | W2 | – | W27 |
Y1 | Compressor Relay | – | Y1 | Y1 | Y1 | Y1 |
G | Fan Relay | G3 | G | G | G | G |
O | Cool Active Reversing Valve | – | – | – | O8 | O8 |
B | Heat Active Reversing Valve | – | – | – | B8 | B8 |
L* | System Malfunction Indicator | – | – | – | L9 | L9 |
C | 24 VAC Transformer Common | C4 | C4,5 | C4,5 | C10 | C10 |
NOTES – Conventional Systems
Thermostat and Display
The Installer Settings must be properly configured in order for this thermostat to operate correctly. The Installer Settings are menu driven. The portion of these settings that do not apply to your setup will be skipped.
No. | Installer Setting | Displayed | Default Setting | Available Settings | Description of Available Settings |
1 | Temperature Scale | DEG | F | F | Select for Fahrenheit temperature display |
C | Select for Celsius temperature display | ||||
Selects a temperature scale of either °F or °C. | |||||
2 | 1st Stage Differential | DIF1 | 0.5 | 0.5, 1.0, 2.0 | Select a 1st stage temperature differential of 0.5°, 1° or 2° F (0.2°, 0.5° or 1.0° C) |
Selects a 1st stage temperature differential which controls the degree of separation between the setpoint temperature and the 1st stage of heating or cooling. | |||||
3 | 2nd Stage Differential | DIF2 | 2.0 | 1.0, 2.0, 3.0 4.0, 5.0, 6.0 | Select a 2nd stage temperature differential of 1°, 2°, 3°, 4°, 5° or 6° F (0.5°, 1.0°, 1.5°, 2.0°, 2.5° or 3.0° C) |
[1230 only] Selects a 2nd stage temperature differential which controls the degree of separation between the 1st and 2nd stage of heating or cooling. | |||||
4 | Compressor Short Cycle Protection (CSCP) | CSCP | 5 | 5, 4, 3, 2, 1, 0 | Select CSCP delay duration in minutes |
Selects the number of minutes the compressor will be locked out after turning off. This delay will run simultaneously with any delay built into the equipment. | |||||
5 | Heat Setpoint Upper Limit | HIGH HEAT | 90 | 90 – 45 (32˚ to 7˚C) | Select a Heat Setpoint Upper Limit of 90° to 45°F (32° to 7°C) |
Selects the upper setpoint adjustment limit that cannot be exceeded in heat mode. | |||||
6 | Heat Setpoint Lower Limit | LOW HEAT | 45 | 45 – 90 (7˚ to 32˚C) | Select a Heat Setpoint Lower Limit of 45° to 90°F (7° to 32°C) |
Selects the lower setpoint adjustment limit that cannot be exceeded in heat mode. | |||||
7 | Cool Setpoint Lower Limit | LOW COOL | 45 | 45 – 90 (7˚ to 32˚C) | Select a Cool Setpoint Lower Limit of 45° to 90°F (7° to 32°C) |
Selects the lower setpoint adjustment limit that cannot be exceeded in cool mode. |
No. | Installer Setting | Displayed | Default Setting | Available Settings | Description of Available Settings |
8 | Cool Setpoint Upper Limit | HIGH COOL | 90 | 90 – 45 (32˚ to 7˚C) | Select a Cool Setpoint Upper Limit of 90° to 45°F (32° to 7°C) |
Selects the upper setpoint adjustment limit that cannot be exceeded in cool mode. | |||||
9 | Installer Lock | INST | NO | NO | Installer Lock disabled |
Y | Installer Lock enabled | ||||
When enabled, a 4-digit lock code can be entered in setting 10. This lock code will be required the next time the Installer Settings menu is accessed. Select NO to skip the installer lock. | |||||
10 | Installer Lock Code | IL | 0000 | 0-9 | Select 0-9 for each digit |
[Only available if Installer Lock was enabled in setting 9] Select a 4-digit lock code (0-9 for each digit) to lock the Installer Settings menu. The code 0000 is not a valid lock code and cannot be used. | |||||
11 | Installer Clear (factory reset) | CLR | NO | NO | Clear disabled – No changes made |
Y | Clear enabled – Factory Reset | ||||
Selecting Y (YES) will return thermostat to all factory default settings. Factory reset will take affect upon exiting Installer settings menu. |
Additional options are located in the User Settings – See User Manual.
Warning Read Before Testing
NOTE: The compressor delay can be bypassed by adjusting Installer Setting 4 – See section 5.
When installed by a professional contractor, this product is backed by a 5-year limited warranty. Limitations apply. For limitations, terms, and conditions, you may obtain a full copy of this warranty:
Installer – store this manual for future reference
Braeburn Systems LLC
2215 Cornell Avenue • Montgomery, IL 60538 Technical Assistance: www.braeburnonline.com Call us toll-free: 866-268-5599 (U.S.)
630-844-1968 (Outside the U.S.)
©2022 Braeburn Systems LLC • All Rights Reserved.
Download Manual
Braeburn 1030 Non-Programmable Thermostat Installer Guide
OTHER MANUALS
Braeburn 1030 Non-Programmable Thermostat User Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…