OPTIONS SELECTION
At the back of the thermostat, there are 3 selection switches to set at your preferences.
The temperature in °C or °F, time in 12 or 24 hours, and Early Start function.
TO SET A TIME AND DAY
Press on the DAY, HOUR and MIN buttons to adjust the time and day.
TO RECORD THE
TO RECORD THE
Select chosen setpoint temperature by using
Press on
TO RECORD THE
To program the Vacation temperature, select the desired degree using the buttons
OPERATING MODES
To select an operating mode, use the MODE button.
AUTO: Runs the program.
Man: Maintains the selected temperature.
NOTE: The “Problems and Solutions” section at the end of this user’s guide will help you to correct your problems during the installation.
This thermostat has been designed to operate with any installation which has a RESISTIVE load not exceeding 4000 W (16.67 A) @ 240 VAC such as electric baseboards, radiant ceilings and floors, electric convectors, etc. It is not compatible with a low-voltage controller used by a central heating system.
Electricians or experienced technicians should install the thermostat.
This thermostat is designed to be used with a self-protected heating system equipped with a thermal cut-off and circuit breaker.
TURN OFF THE POWER OF THE HEATING SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. Keep the air vents of the thermostat clean and free from obstructions.
NOTE: All cables and connections must conform to the local electrical code.
WARNING: Special CO/ALR solderless connectors must be used when connecting with aluminum conductors.
Set the On/Off switch to On.
When power is applied for the first time, the display must show the time 00:00, the room temperature and the Manual mode icon (
NOTE: The On/Off switch set to Off will place the thermostat in sleep mode. Ideal for summertime.
The TH110A-DP-P has two (2) operating modes.
MANUAL (
This mode allows you to maintain a constant temperature in the room.
AUTOMATIC (
This mode executes your own programming.
To activate this mode, press on the Mode button to display the icon. The
Memory back-up
In the event of a power failure, an internal circuit will maintain the programming and the time. But only the time could have to be set if the power failure is more than 2 hours.
Early Start function
The thermostat is providing a built-in function enabling it to calculate the optimum time to start the heating system to achieve the desired temperature setting at the programmed time. This function could start the heating system as early as 6 hours prior to the programmed time. To enable this function, set the switch E.S. to “ON” at the back of the thermostat.
Programming the time and day
Programming the Comfort, Economy and Vacation settings
The Comfort
To program your settings
The TH110A-DP-P allows 4 setting changes for each day of the week. There are no pre-set programs. The programs are tailored to perfectly adapt to your lifestyle. The principle is very simple. For each day, enter the time at which you wake up (P1), the time you leave for work (P2), the time you arrive back home (P3), and the time you go to bed (P4).
Program | Mode | Time |
1 | Wake-up time | |
2 | Leaving time | |
3 | Return time | |
4 | Bed time |
For savings to be obtained, you must lower the temperature for a period of 2 to 3 times the delay required to bring the temperature back to your comfort level.
Example: If your system takes one hour to go from your saving temperature level to your comfort temperature level, it is useless to lower the temperature for a period less than 2 to 3 hours.
Schedule/Day | MON. | TUES. | WED. | THU. | FRI. | SAT. | SUN. |
PROG. 1 | 6:15 AM | 6:15 AM | 6:15 AM | 6:15 AM | 6:15 AM | 7:30 AM | 7:30 AM |
PROG. 2 | 8:15 AM | 8:15 AM | 8:15 AM | 8:15 AM | 8:15 AM | — | — |
PROG. 3 | 5 PM | 5 PM | 5 PM | 5 PM | 5 PM | — | — |
PROG. 4 | 10 PM | 10 PM | 10 PM | 10 PM | 10 PM | 11 PM | 11 PM |
NOTE: It is faster to program the same schedule for every day and then modify the exception days.
Temporary or permanent temperature bypass
This operation allows you to temporarily modify the room temperature while you are in the Automatic mode. Simply press on or button to select the desired temperature, or the or button to select the Comfort or Econo settings you have programmed.This temperature will be maintained until the beginning of the next programmed schedule.
You can also switch to the Vacation setting for a prolonged absence by pressing on and at the same time.The display will show icon. In that case, the derogation is permanent. To return to the normal operating mode, press on Mode button.
If you wish to immediately return to the programmed settings, press on Mode button twice.
AUBE TECHNOLOGIES INC. ONE (1) YEAR LIMITED WARRANTY
This product is warranted against material defects and workmanship in normal use for a period of one year, from the date of the original purchase from authorized dealers. During this period, AUBE technologies inc. will repair or replace the product with a new or of equivalent quality at AUBE’S option, without charge, any product proven defective in normal use. The warranty does not cover transportation costs. Nor does it cover a product subjected to misuse or accidental damage. This warranty does not cover the cost of installation, removal or reinstallation.
This limited warranty is in lieu of all other warranties, obligations or liabilities expressed or implied by the company. In no event shall AUBE technologies inc. be liable for consequential or incidental damages resulting from installation of this product. Some states or provinces do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, so the above exclusions or limitations may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
The defective product and the original sale receipt must be returned to the original dealer or shipped prepaid, insured, and addressed to:
Aube technologies inc., 705 Montrichard, Iberville (Quebec), Canada, J2X 5K8
www.aubetech.com
service@aubetech.com
If you have any questions concerning the installation or programming of this product, please call our technical assistance at (450) 358-4600 for the Montreal area or 1-800-831-AUBE for the outside area, Monday to Friday between 8:30 AM and 5:00 PM Eastern time.
No display | • Circuit breaker is open • Power failure • The thermostat switch is in the Off position | • Check 240 VAC presence at the thermostat • Put the switch in the On position |
The thermostat is loosing the time but not the programming | • Power failure of more than 2 hours | |
The room temperature shown is wrong | • A draft is nearby the thermostat | • Eliminate the draft |
Programs do not change as you want | • Incorrect programming hours • Wrong programming mode selected | • Check actual time in AM & PM as well as program times (AM is not displayed) • Make sure the operating mode is set to AUTO |
Download Manual
Aube Technologies TH110A-DP-P Thermostat User manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…