SUMMARY

OPTIONS SELECTION
At the back of the thermostat, there are 3 selection switches to set at your preferences.

The temperature in °C or °F, time in 12 or 24 hours, and Early Start function.
TO SET A TIME AND DAY
Press on the DAY, HOUR and MIN buttons to adjust the time and day.
TO RECORD THEAube Technologies-TH110A-DP-P-Thermostat-FIG.2 (COMFORT) SETPOINT TEMPERATURE Select chosen setpoint temperature by usingAube Technologies-TH110A-DP-P-Thermostat-FIG.3 or button. Press on button (app. 3 seconds) until the icon appears on display.
TO RECORD THE Aube Technologies-TH110A-DP-P-Thermostat-FIG.4(ECONOMY) SETPOINT TEMPERATURE
Select chosen setpoint temperature by using Aube Technologies-TH110A-DP-P-Thermostat-FIG.3 the button.
Press on Aube Technologies-TH110A-DP-P-Thermostat-FIG.4button (app. 3 seconds) until the icon appears on display.
TO RECORD THEAube Technologies-TH110A-DP-P-Thermostat-FIG.5 (VACATION) SETPOINT TEMPERATURE
To program the Vacation temperature, select the desired degree using the buttonsAube Technologies-TH110A-DP-P-Thermostat-FIG.3 and press on the buttons simultaneously until the iconAube Technologies-TH110A-DP-P-Thermostat-FIG.5 is displayed (app. 3 seconds).
OPERATING MODES
To select an operating mode, use the MODE button.
AUTO: Runs the program. Aube Technologies-TH110A-DP-P-Thermostat-FIG.3 shows temperature settings and can override temporarily your programming up to the next program.
Man: Maintains the selected temperature. Aube Technologies-TH110A-DP-P-Thermostat-FIG.3or changes the temperature setting.
Aube Technologies-TH110A-DP-P-Thermostat-FIG.1

INSTALLATION

NOTE: The “Problems and Solutions” section at the end of this user’s guide will help you to correct your problems during the installation.
This thermostat has been designed to operate with any installation which has a RESISTIVE load not exceeding 4000 W (16.67 A) @ 240 VAC such as electric baseboards, radiant ceilings and floors, electric convectors, etc. It is not compatible with a low-voltage controller used by a central heating system.
Electricians or experienced technicians should install the thermostat.
This thermostat is designed to be used with a self-protected heating system equipped with a thermal cut-off and circuit breaker.

PARTS INCLUDED

  • One (1) TH110A-DP-P (240 VAC) thermostat
  • Two (2) 6-32 screws
  • Four (4) solderless connectors (for copper wire)

TURN OFF THE POWER OF THE HEATING SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. Keep the air vents of the thermostat clean and free from obstructions.Aube Technologies-TH110A-DP-P-Thermostat-FIG.6

NOTE: All cables and connections must conform to the local electrical code.
WARNING: Special CO/ALR solderless connectors must be used when connecting with aluminum conductors.

Power-upAube Technologies-TH110A-DP-P-Thermostat-FIG.7

Set the On/Off switch to On.
When power is applied for the first time, the display must show the time 00:00, the room temperature and the Manual mode icon ( Aube Technologies-TH110A-DP-P-Thermostat-FIG.8). Other information might show up on the display if the installation is defective or does not comply with the instructions.
NOTE: The On/Off switch set to Off will place the thermostat in sleep mode. Ideal for summertime.

OPERATING MODES

The TH110A-DP-P has two (2) operating modes.
MANUAL ( Aube Technologies-TH110A-DP-P-Thermostat-FIG.8)
This mode allows you to maintain a constant temperature in the room.

  1. To activate this mode, press on Mode button to display the icon.
  2. Set the desired temperature using the buttons or select the pre-programmed or or settings.
    (To select the setting, press on and simultaneously.)

AUTOMATIC (Aube Technologies-TH110A-DP-P-Thermostat-FIG.9 )
This mode executes your own programming.
To activate this mode, press on the Mode button to display the icon. The Aube Technologies-TH110A-DP-P-Thermostat-FIG.2 or Aube Technologies-TH110A-DP-P-Thermostat-FIG.4icon indicates which temperature setting is used. Also, the icon of the program number will be shown.

Memory back-up
In the event of a power failure, an internal circuit will maintain the programming and the time. But only the time could have to be set if the power failure is more than 2 hours.
Early Start function
The thermostat is providing a built-in function enabling it to calculate the optimum time to start the heating system to achieve the desired temperature setting at the programmed time. This function could start the heating system as early as 6 hours prior to the programmed time. To enable this function, set the switch E.S. to “ON” at the back of the thermostat.

PROGRAMMING

Programming the time and day

  1. Set the time using the Hour and Min buttons.
  2. Set the day using the Day button.

Programming the Comfort, Economy and Vacation settings
The ComfortAube Technologies-TH110A-DP-P-Thermostat-FIG.2, EconomyAube Technologies-TH110A-DP-P-Thermostat-FIG.4, and Vacation Aube Technologies-TH110A-DP-P-Thermostat-FIG.5settings respectively represent the temperatures that you wish to have during the day Aube Technologies-TH110A-DP-P-Thermostat-FIG.2, at night or while you are away at workAube Technologies-TH110A-DP-P-Thermostat-FIG.4 , or while you are away for an extended periodAube Technologies-TH110A-DP-P-Thermostat-FIG.5.

To program your settings

  1. To program the Comfort temperature, select the desired degree using the Aube Technologies-TH110A-DP-P-Thermostat-FIG.3buttons and press theAube Technologies-TH110A-DP-P-Thermostat-FIG.2 button until the icon is displayed (app. 3 seconds).
  2. To program the Economy temperature, select the desired degree using the Aube Technologies-TH110A-DP-P-Thermostat-FIG.3buttons and press theAube Technologies-TH110A-DP-P-Thermostat-FIG.4 button until the icon is displayed (app. 3 seconds).
  3. To program the Vacation temperature, select the desired degree using theAube Technologies-TH110A-DP-P-Thermostat-FIG.3 buttons Aube Technologies-TH110A-DP-P-Thermostat-FIG.2and Aube Technologies-TH110A-DP-P-Thermostat-FIG.4press on the buttons simultaneously until theAube Technologies-TH110A-DP-P-Thermostat-FIG.5 icon is displayed (app. 3 seconds).
  4. Press the Mode button to exit this function and return to the normal operating mode.

Schedule programming

The TH110A-DP-P allows 4 setting changes for each day of the week. There are no pre-set programs. The programs are tailored to perfectly adapt to your lifestyle. The principle is very simple. For each day, enter the time at which you wake up (P1), the time you leave for work (P2), the time you arrive back home (P3), and the time you go to bed (P4).

Program Mode Time
1 Aube Technologies-TH110A-DP-P-Thermostat-FIG.2 Wake-up time
2 Aube Technologies-TH110A-DP-P-Thermostat-FIG.4 Leaving time
3 Aube Technologies-TH110A-DP-P-Thermostat-FIG.2 Return time
4 Aube Technologies-TH110A-DP-P-Thermostat-FIG.4 Bed time

For savings to be obtained, you must lower the temperature for a period of 2 to 3 times the delay required to bring the temperature back to your comfort level.
Example: If your system takes one hour to go from your saving temperature level to your comfort temperature level, it is useless to lower the temperature for a period less than 2 to 3 hours.

  1. To program your schedule
    • Press on the PGM button to access the programming mode.
    • Press on the Day button to select the day to be programmed. You can select all days of the week by pressing on Day button for 3 seconds.
    • Press on the PGM button to select programs 1, 2, 3 or 4.
    • Press on the Hour and Min buttons to program the time.
    • When you have completed your programming, press on Mode button to exit this function.
  2. To erase a program :
    Select the program using PGM and Day buttons, and press on Clear button. The time field displays –:– when the program is inactive.
  3. Example 1 : Comfort period from 7:00 AM to 10:30 PM
    The economy period from 10:30 PM to 7:00 AM
    Identical schedule for all days of the week.
    • Press on the PGM button to access the programming mode.
    • Press on the Day button 3 seconds to select every day of the week.
    • Press on the Hour button to enter 7:00 AM, Prog. 1 ( ).
    • Press on the PGM button again to select Prog. 2 ( ), and press on Hour and Min buttons to enter 10:30 PM.
    • Press on Mode button to exit this function.
  4. Example 2 : Comfort period: Monday to Friday from 6:15 AM to 8:15 AM and from 5:00 PM to 10:00 PM. Saturday & Sunday from 7:30 AM to 11:00 PM.
Schedule/Day MON. TUES. WED. THU. FRI. SAT. SUN.
PROG. 1Aube Technologies-TH110A-DP-P-Thermostat-FIG.2 6:15 AM 6:15 AM 6:15 AM 6:15 AM 6:15 AM 7:30 AM 7:30 AM
PROG. 2Aube Technologies-TH110A-DP-P-Thermostat-FIG.4 8:15 AM 8:15 AM 8:15 AM 8:15 AM 8:15 AM
PROG. 3Aube Technologies-TH110A-DP-P-Thermostat-FIG.2 5 PM 5 PM 5 PM 5 PM 5 PM
PROG. 4Aube Technologies-TH110A-DP-P-Thermostat-FIG.4 10 PM 10 PM 10 PM 10 PM 10 PM 11 PM 11 PM

NOTE: It is faster to program the same schedule for every day and then modify the exception days.

  1. Press on PGM button to access the programming mode.
  2. Press on Day button 3 seconds to select every day of the week.
  3. Press on Hour and Min buttons to enter 6:15 AM, Prog. 1 ( Aube Technologies-TH110A-DP-P-Thermostat-FIG.2).
  4. Press on the PGM button to select Prog. 2 ( Aube Technologies-TH110A-DP-P-Thermostat-FIG.4) and Hour and Min buttons to enter 8:15 AM.
  5. Repeat step 4 to enter Prog. 3 (5:00 PM) and Prog. 4 (10:00 PM).
    NOTE: When making modifications, make sure you are in the right program.
    To modify the Saturday and Sunday schedules:
  6. Press on Day button until SA or SU is displayed.
  7. Press on the PGM button to select Prog. 1 (Aube Technologies-TH110A-DP-P-Thermostat-FIG.2 ) and Hour and Min buttons to enter 7:30 AM.
  8. Press on PGM button to select Prog. 2 (Aube Technologies-TH110A-DP-P-Thermostat-FIG.4 ) and then Clear button to erase it.
  9. Press on PGM button to select Prog. 3 ( Aube Technologies-TH110A-DP-P-Thermostat-FIG.2) and then Clear button to erase it
  10. Press on the PGM button to select Prog. 4 (Aube Technologies-TH110A-DP-P-Thermostat-FIG.2 ) and then Hour and Min buttons to enter 11:00 PM.
  11. Press on Mode button to exit this function.

Temporary or permanent temperature bypass
This operation allows you to temporarily modify the room temperature while you are in the Automatic mode. Simply press on or button to select the desired temperature, or the or button to select the Comfort or Econo settings you have programmed.This temperature will be maintained until the beginning of the next programmed schedule.
You can also switch to the Vacation setting for a prolonged absence by pressing on and at the same time.The display will show icon. In that case, the derogation is permanent. To return to the normal operating mode, press on Mode button.
If you wish to immediately return to the programmed settings, press on Mode button twice.

CHARACTERISTICS

  • Model: TH110A-DP-P (240 VAC)
  • Supply: 240 VAC, 50/60 Hz
  • Load: 16.67 A maximum (resistive only)
  • Power: 4000 watts (NI) @ 240 VAC
  • Approvals: CSA / UL
  • Display range: 0 to 60 °C (32 to 140 °F)
  • Setting range: 5 to 30 °C (40 to 85 °F)
  • Comfort default setting: 20 °C (68 °F)
  • Econo default setting: 18 °C (64 °F)
  • Vacation default setting: 10 °C (50 °F)
  • Storage: -20 to 50 °C (-4 to 120 °F)

WARRANTY

AUBE TECHNOLOGIES INC. ONE (1) YEAR LIMITED WARRANTY
This product is warranted against material defects and workmanship in normal use for a period of one year, from the date of the original purchase from authorized dealers. During this period, AUBE technologies inc. will repair or replace the product with a new or of equivalent quality at AUBE’S option, without charge, any product proven defective in normal use. The warranty does not cover transportation costs. Nor does it cover a product subjected to misuse or accidental damage. This warranty does not cover the cost of installation, removal or reinstallation.
This limited warranty is in lieu of all other warranties, obligations or liabilities expressed or implied by the company. In no event shall AUBE technologies inc. be liable for consequential or incidental damages resulting from installation of this product. Some states or provinces do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, so the above exclusions or limitations may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
The defective product and the original sale receipt must be returned to the original dealer or shipped prepaid, insured, and addressed to:
Aube technologies inc., 705 Montrichard, Iberville (Quebec), Canada, J2X 5K8
www.aubetech.com
[email protected]
If you have any questions concerning the installation or programming of this product, please call our technical assistance at (450) 358-4600 for the Montreal area or 1-800-831-AUBE for the outside area, Monday to Friday between 8:30 AM and 5:00 PM Eastern time.

PROBLEMS AND SOLUTIONS

No display •  Circuit breaker is open

•  Power failure

•  The thermostat switch is in the Off position

•  Check 240 VAC presence at the thermostat

•  Put the switch in the On position

The thermostat is loosing
the time but not the programming
•  Power failure of more than 2 hours
The room temperature shown is wrong •  A draft is nearby the thermostat •  Eliminate the draft
Programs do not change as you want •  Incorrect programming hours
•  Wrong programming mode selected
• Check actual time in AM & PM as well as program times

(AM is not displayed)

• Make sure the operating mode is set to AUTO

REFERENCE

Download Manual

Aube Technologies TH110A-DP-P Thermostat User manual

aube logo

Aube Technologies TH110A-DP-P Thermostat User manual

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post’s permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post’s URL again. (Find out more about Webmentions.)