Do you know your thermostat configuration?
To know whether your new thermostat is configured in programmable mode or non-programmable mode, look for the time and day display on the thermostat screen. If the time and day appear on the screen, the thermostat is configured as a programmable thermostat. Refer to the table of contents on the next page for sections that apply to your thermostat configuration.
Need Help?
For assistance with this product please visit www.aubetech.com or call customer assistance toll-free at 1-800-831-2823.
Press Décompte (Countdown) to set a new temperature and to select the time you wish to hold this temperature setting. The thermostat will return to its previous or programmed temperature setting at the end of the countdown time. The countdown time is selectable from 15 minutes to 14 days.
The Countdown mode is not available when the thermostat is locked.
Thermostat display in programmable mode
The thermostat displays the current time and day when the thermostat is configured in programmable mode. When the thermostat is following the schedule, it also displays the current period of the schedule: Réveil (Wake), Départ (Leave), Retour (Return) or Sommeil (Sleep). The period is not displayed when the thermostat is placed in Maintien temporaire (Temporary Hold) or Maintien permanent (Permanent Hold).
Exécute l’horaire (Run Schedule) appears on the screen when the thermostat is following the programmed schedule. Your thermostat has been programmed with an energy-saving schedule which can reduce your heating expenses by as much as 33%.
Monday to Friday (Lu, Ma, Me, Je & Ve) | Saturday and Sunday (Sa & Di) | |||
Period | Starting time | Temperature | Starting time | Temperature |
Réveil (Wake) | 6h (6:00 AM) | 21.0°C (70°F) | 8h (8:00 AM) | 21.0°C (70°F) |
Départ (Leave) | 8h (8:00 AM) | 16.5°C (62°F) | – – – – | – – |
Retour (Return) | 18h (6:00 PM) | 21.0°C (70°F) | – – – – | – – |
Sommeil (Sleep) | 22h (10:00 PM) | 16.5°C (62°F) | 22h (10:00 PM) | 16.5°C (62°F) |
The schedule consists of 4 periods per day, which represents a typical weekday. However, you can program the thermostat to skip (cancel) the periods that do not apply to your situation. For example, Départ (Leave) and Retour (Return) periods are skipped for the weekend in the default schedule. You can choose a different program every day; i.e., each period can have a different starting time and a different temperature every day
If you wish to clear a period (e.g. you may want to skip the Leave and Return periods if you stay home all day), select the period (step 4) and press
Temporary Hold (Maintien temporaire
Use Temporary Hold (Maintien temporaire) mode to temporarily bypass the schedule and set a new temperature. The thermostat will hold the new temperature during the current period. The thermostat will resume the heating schedule when the next period starts or if you press Annuler (Cancel
Permanent Hold (Maintien permanent)
Use Permanent Hold (Maintien permanent) mode to bypass the schedule and set a new temperature for an indefinite period of time. To resume the heating schedule, press Annuler (Cancel).
Use the Copie function to transmit the schedule settings of this thermostat to other EConnect™ wireless thermostats in your house
Setup functions | Default setting | Options |
Temperature and time formats * | °C | °C / °F |
24h | 12h / 24h | |
Programmable mode (Horaire) ** | On (Oui) | On/Off (Oui/Non) |
Adaptive Intelligent Recovery (Horaire Anticipé) *** | On (Oui) | On/Off (Oui/Non) |
Accessing the advanced setup menu
Thermostat
Install 2 new alkaline AA batteries when the Piles faibles (Low batteries) warning starts flashing. It is recommended to replace batteries once a year, or when you will be away for more than a month. To access the batteries, pull the thermostat from its mounting plate. You will need to set the time and date if new batteries are not inserted within 2 minutes after the old ones are removed. However, other settings are not erased. After new batteries are installed, the thermostat will automatically restore communication with the wireless network within a few minutes.
Outdoor air sensor
Install 2 new AA lithium batteries when the Sonde extérieure Piles faibles (Outdoor Air Sensor Low Batteries) warning starts flashing on the thermostat. To access the old batteries, remove the sensor from the bracket and remove the sensor cover. After new batteries are installed, the sensor will automatically restore communication with the wireless network within a few minutes.
ELECTRICAL HAZARD
The servicing or rewiring of any equipment interface module (EIM) linked to this thermostat must be done by a certified electrician.
Three-year limited warranty
Honeywell warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of three (3) years from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defective or malfunctions, Honeywell shall repair or replace it (at Honeywell’s option). If the product is defective, (i) return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it, or (ii) contact Honeywell. Honeywell will make the determination whether the product should be returned, or whether a replacement product can be sent to you. This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer. Honeywell’s sole responsibility shall be to repair or replace the product within the terms stated above. HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some provinces, states or regions do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you. THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE THREE-YEAR DURATION OF THIS WARRANTY. Some provinces, states or regions do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary from one province, state or region to another.
FCC Compliance Statement (Part 15.19) (USA only)
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
FCC Warning (Part 15.21) (USA only)
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
FCC Interference Statement (Part 15.105 (b)) (USA only)
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
EIM, thermostats and outdoor sensor
To comply with FCC and Industry Canada RF exposure limits for general population/ uncontrolled exposure, the antenna(s) used for these transmitters must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.
Remote control
This portable transmitter with its antenna complies with FCC and Industry Canada RF exposure limits for general population/uncontrolled exposure. This device must not be co-located or operating in conjunction with any other antenna or transmitter.
Section 7.1.3 of RSS-GEN
Operation is subject to the following two conditions:
Section 7.1.2 of RSS-GEN
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (EIRP) is not more than that necessary for successful communication.
Automation and Control Solutions
Honeywell International Inc.
1985 Douglas Drive North
Golden Valley, MN 55422
http://yourhome.honeywell.com
Honeywell Limited
705 Montrichard
Saint-Jean-sur-Richelieu, Quebec, J2X 5K8
www.aubetech.com
DOWNLOAD MANUAL
Aube Technologies TA7210 Non-programmable Thermostat Operating Manual
Aube Technologies TA7210 Non-programmable Thermostat Operating Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…