To connect the 8810 thermostats to a Wi-Fi network follow the steps below.
Note: You will need a computer or mobile device with Wi-Fi and a web browser.
The thermostat should be mounted:
Do not mount the thermostat:
OUTDOOR TEMPERATURE SENSOR (OPTIONAL)
Heat pump applications can use the outdoor temperature to effectively utilize the heat pump:
WIRING TERMINAL
SYSTEM SETUP INSTRUCTIONS
The following instructions show how to enter the system setup menu and change settings. The table on the following pages lists the settings and their details. Default settings are shown in bold. Some settings are only available based on other setting values.
How to enter the system setup menu to change system settings
System setting | Description | Factory default setting (bold) and setting range |
00 . Automation Enable | Selects if the thermostat connects with an automation system or an Aprilaire account . | 0: Aprilaire Cloud 1: Automation System |
01 . Equipment Type | Equipment type set by SW1 . | 0: Heat/Cool 1: Heat Pump |
02 . Temperature Scale | Set the thermostat to Fahrenheit or Celsius mode . | 0: Fahrenheit 1: Celsius |
03 . Reversing Valve | Selects O or B operation . | 0: O – On in cooling 1: B – On in heating |
04 . Control Setup | Used to lockout heating or cooling outputs . Note: Only available if Equipment Type is set to Heat/Cool . | 0: Heat and Cool 1: Heat Only 2: Cool Only |
05 . Heat/Cool: Cooling Stages Heat Pump: Compressor Stages | Heat/Cool: Number of Cooling Stages . Heat Pump: Number of Compressor Stages . | 0: One 1: Two |
06 . Heat/Cool: Heating Stages Heat Pump: Aux Heat Stages | Heat/Cool: Number of Heat Stages . Heat Pump: Number of Auxiliary Heat Stages . | 0: One 1: Two |
System setting | Description | Factory default setting (bold) and setting range |
07 . Heat/Cool: Fan Control in Heating Heat Pump: Auxiliary Equipment Type | Heat/Cool: Determines if the thermostat or equipment controls the fan in heating . Heat Pump: Auxiliary Equipment type . | 0: Gas/Oil Heat (equipment controls fan) 1: Electric Heat (thermostat controls fan) |
10 . Temperature Sensor Offset | Field adjustment of temperature sensor . | 0° (no offset applied) -4°F to +4°F (-2°C to +2°C) |
12 . Auto Changeover | Enable or disable auto changeover mode . | 0: Disable 1: Enable |
13 . Deadband | Auto Changeover mode deadband . | 3°F (1.5°C) 2°F to 9°F (1°C to 4 .5°C) |
15 . Outdoor Sensor | Selects if an outdoor temperature sensor is not installed, a wired sensor is installed, or the outdoor temperature is provided by the automation system . Note: Automation is only available if Automation Enable is set to Automation . | 0: Not installed 1: Installed 2: Automation |
18 . Compressor Min Off Time | Minimum off time for compressor protection . | 5 minutes 1 to 5 minutes |
System setting | Description | Factory default setting (bold) and setting range |
19 . Heating Min Off Time | Minimum off time for heating . | 2 minutes 1 to 5 minutes |
20 . Equipment Min On Time | Minimum on time for heating and cooling . | 2 minutes 1 to 5 minutes |
22 . First Stage Differential | First stage differential . | 1°F (0.5°C) 1°F to 9°F (0 .5°C to 4 .5°C) |
23 . Second Stage Differential | Second stage differential . | 1°F (0.5°C) 1°F to 9°F (0 .5°C to 4 .5°C) |
24 . Third Stage Differential | Third stage differential . | 1°F (0.5°C) 1°F to 9°F (0 .5°C to 4 .5°C) |
25 . Fourth Stage Differential | Fourth stage differential . | 1°F (0.5°C) 1°F to 9°F (0 .5°C to 4 .5°C) |
26 . Away | Enables the Away feature . The Away feature allows the automation system or Aprilaire mobile and web apps to use a single button press to set the thermostat to a predefined setpoint(s) . The thermostat will hold the setpoint(s) until Away is canceled with the automation system or app or at the thermostat . | 0: Disable 1: Enable |
System setting | Description | Factory default setting (bold) and setting range |
27 . Heat Blast | Enables the Heat Blast® feature . The Heat Blast feature is only available with the automation system or Aprilaire mobile and web apps, and will raise the current room temperature 3°F to 5°F based on the Blast Offset and then resume normal operation . Heat Blast can be canceled with the automation system or the Aprilaire mobile and web apps, or at the thermostat . | 0: Disable 1: Enable |
28 . Blast Offset | Amount of heating when Heat Blast is initiated . | 3°F (1.5°C) 3°F to 5°F (1 .5°C to 2 .5°C) |
37 . Stage Rate | Accumulation of equipment run time in equipment staging determination . 1 = more rapid staging of equipment (comfort) . 5 = slower staging of equipment (economy) . | 2 1 to 5 or “OFF” to ignore accumulated run time . |
38 . Progressive Recovery | Enable or disable progressive recovery . | 0: Disable 1: Enable |
39 . Low Balance Point | Outdoor temperature low balance point . Note: This option is only available if the outdoor sensor is set to Installed or Automation . | 20°F or -8°C 0°F to 60°F (-18°C to 12°C) or OFF to ignore LBP |
System setting | Description | Factory default setting (bold) and setting range |
40 . High Balance Point | Outdoor temperature high balance point . Note: This option is only available if the outdoor sensor is set to Installed or Automation . | 65°F or 14.5°C 0°F to 80°F (-18°C to 22°C) or OFF to ignore HBP |
41 . Program Format | Enables the 7 day program . | 0: 7-Day 1: Non-Prog |
54 . Change Air Filter Reminder | The period displaying the Change Air Filter reminder . | OFF 1 to 12 months |
55 . Change Water Panel Reminder | The time until the first Change Water Pnl message is displayed . | OFF 1 to 12 months |
56 . Humidifier Type | Selects the type of humidifier . If humidifier type is set to Drain-less, then the first reminder is based on the system setting 55, the second reminder will activate 3 months later . If humidifier type is set to Flow through, then the first reminder is based on system setting 55, the second reminder will activate 12 months later . | 0: Flow through type humidifier (1 reminder per season) 1: Drain-less type humidifier (2 reminders per season) |
Test Number | Heat/Cool | Heat Pump |
50 | Heating (W) (W2) | Compressor Heating (Y) (Y2) |
51 | Aux Heating (W) (W2) | |
52 | Cooling (Y) (Y2) | Compressor Cooling (Y) (Y2) |
53 | Fan (G) | Fan (G) |
How to enter the system test menu
Test steps for Heat/Cool | |||||||||
Step | Key Input | System Setting | Display (Output) | ||||||
#07 | 01 HEATING ON (W) | 02 HEATING ON (W2) | 01 COOLING ON (Y) | 02 COOLING ON (Y2) | 01 FAN ON (G) | ||||
#50 Heat | 1st [UP] | 0 : Gas | ON | ||||||
1 : Elec | ON | ON | |||||||
2nd [UP] | 0 : Gas | ON | ON | ||||||
1 : Elec | ON | ON | ON | ||||||
[DOWN] | |||||||||
#52 Cool | 1st [UP] | ON | ON | ||||||
2nd [UP] | ON | ON | ON | ||||||
[DOWN] | |||||||||
#53 Fan | [UP] | ON | |||||||
[DOWN] |
Test steps for Heat Pump | |||||||||
Step | Key Input | System Setting | Display (Output) | ||||||
#07 | #03 | 01 AUX HEATING ON (W) | 02 AUX HEATING ON (W2) | 01 COOL/HEAT ON (Y) | 02 COOL/HEAT ON (Y2) | 01 FAN ON (G) | O/B | ||
#50 Heat | 1st [UP] | 0 : O | ON | ON | |||||
1 : B | ON | ON | ON | ||||||
2nd [UP] | 0 : O | ON | ON | ON | |||||
1 : B | ON | ON | ON | ON | |||||
[DOWN] | 0 : O | ||||||||
1 : B | ON | ||||||||
#51 Aux | 1st [UP] | 0 : Gas | ON | ||||||
1 : Elec | ON | ON | |||||||
2nd [UP] | 0 : Gas | ON | ON | ||||||
1 : Elec | ON | ON | ON | ||||||
[DOWN] | |||||||||
#52 Cool | 1st [UP] | 0 : O | ON | ON | ON | ||||
1 : B | ON | ON | |||||||
2nd [UP] | 0 : O | ON | ON | ON | ON | ||||
1 : B | ON | ON | ON | ||||||
[DOWN] | 0 : O | ON | |||||||
1 : B | |||||||||
#53 Fan | [UP] | ON | |||||||
[DOWN] |
DISPLAY IS BLANK
TEMPERATURE SETTINGS DO NOT CHANGE
HEATING SYSTEM DOES NOT RESPOND (“HEATING” APPEARS ON SCREEN)
COOLING SYSTEM DOES NOT RESPOND (“COOLING” APPEARS ON SCREEN)
FAN DOES NOT TURN ON IN A CALL FOR HEAT
HEAT PUMP ISSUES COOL AIR IN HEAT MODE, OR WARM AIR IN COOL MODE
HEAT/COOL BOTH ON AT SAME TIME
HEATING EQUIPMENT IS RUNNING IN COOL MODE
“HEATING” IS NOT DISPLAYED
“COOLING” IS NOT DISPLAYED
Environment | |
Temperature | Operating: 32° to 120°F (0° to 48 .9°C) Shipping: -30° to 140°F (-34 .4° to 60°C) |
Relative humidity | Operating: 5% to 90% R .H . (non-condensing) |
Electrical | |
Operating voltage | 24 VAC (18 – 30 VAC) |
Current | Maximum: 2 .5A (total), 1 .0A (single output) Maximum surge current: 5A |
Thermal | |
Outdoor temperature sensor | Maximum distance: 300 feet |
Room temperature measurement | Display range: 32° to 99°F (0° to 40°C) |
Outdoor temperature measurement | Display range: -40° to 130°F (-40° to 55°C) |
Heat: 40° to 90°F | |
Temperature setting | (4° to 32°C) |
range | Cool: 50° to 99°F |
(10° to 37°C) |
U.S. Patent Numbers 8,146,376, 8,596,078 and other patents pending.
© 2015 Aprilaire – A division of Research Products Corporation
Download Manual:
Aprilaire 8810 TouchScreen Wi-Fi Thermostat Installation Instruction
other manuals:
Aprilaire 8810 TouchScreen Wi-Fi Thermostat Owner Manual
Aprilaire 8810 TouchScreen Wi-Fi Thermostat Installation Instruction
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…