THERMOSTAT FEATURES
CONTROLS & DISPLAY OVERVIEW
NOTE: THE BACKLIGHT IS ACTIVATED WITH THE FIRST BUTTON PRESS AND AUTOMATICALLY TURNS OFF.
For detailed instructions for connecting the thermostat to a Wi-Fi network and registering it to an Aprilaire account, refer to the Wi-Fi Quick Start Guide included in the box. Visit my.aprilaire.com for instructions about using the Aprilaire web and mobile apps.
SELECT SYSTEM MODE (OFF/HEAT/EM-HEAT/COOL/AUTO)
Press and hold
SET TIME AND DAY
Understanding program schedules
The daily schedule is split into four sections:
Understanding program schedules (continued)
Event | Event designator | Start time | Set temps | |
Heat | Cool | |||
1 | WAKE | 6:00AM | 70°F (21°C) | 78°F (25 .5°C) |
2 | LEAVE | 8:00AM | 62°F (16 .5°C) | 85°F (29 .5°C) |
3 | RETURN | 5:00PM | 70°F (21°C) | 78°F (25 .5°C) |
4 | SLEEP | 10:00PM | 62°F (16 .5°C) | 82°F (27 .5°C) |
The Progressive Recovery feature allows the thermostat to activate the heating and cooling equipment prior to an event in order to reach the desired temperature at the start of the next scheduled event.
Example:
Set the Wake time to 6 am, and the temperature to 70°F. The heat will come on before 6 am, so the temperature is 70°F by the time you wake at 6 am.
Program schedule overrides (temporary, permanent, AWAY, HEAT BLAST)
Temporary program override
Press or to immediately adjust the temperature. This will temporarily override the temperature setting for the current programmed time period. The new temperature setting will be maintained until the next time period of the programmed schedule. To cancel the temporary override, press twice.
Press
The Away feature, if enabled, allows the thermostat to be set to a predefined setpoint(s) by simply pressing the Away button in your App. By default the cooling setpoint is 85°F (29.5°C), the default heating setpoint is 62°F (16.5°C) and the default clean air/fan mode is Auto. The default settings can be modified in the App. To cancel Away at the thermostat press
Heat Blast®
The Heat Blast® feature will raise the current room temperature by 3°F to 5°F based on the installer set-up, and then resume normal operation. To activate a Heat Blast, press the Heat Blast button in the App.
Note: Heat Blast can only be activated in the App, and is only available in the App if it is enabled in the Installer Setup and the thermostat is in Heat or Emergency Heat mode. To cancel Heat Blast at the thermostat press , or the or buttons.
The following instructions show how to enter the Wi-Fi Setting menu and change settings. The table below lists the settings and their detail. Default settings are shown in bold. How to enter the Wi-Fi settings menu to change settings.Press and hold and for three seconds. The screen will display the first setting.
Wi-Fi setting | Description | Factory default setting (bold) and setting range |
47 . WiFi Disconnect and Clear Settings | Disconnects the Thermostat from the router and clears the Wi-Fi settings. Use this to set the thermostat back to provisioning mode so it can be connected to a new Wi-Fi router . | 0: No1: Yes |
48 . Turn WiFi Radio On/Off | Use to turn the Wi-Fi radio on or off . Wi-Fi settings will be maintained if the radio is set to Off . | 0: Off1: On |
49 . Unregister the Thermostat | Unregisters the thermostat from an Aprilaire account . Use this when the thermostat needs to be registered to a new Aprilaire account . For instance, if you have purchased a home with the thermostat already installed, this setting would allow you to clear the previous registration so that you can register the thermostat to your account . | 0: No1: Yes |
If you purchase a new Wi-Fi router or change the security settings on your existing router the router settings in the thermostat need to be cleared so the new Wi-Fi router settings can be entered. To do this, enter the Wi-Fi settings menu as described in the Accessing Wi-Fi Settings Menu section. Change the setting for WiFi Disconnect and Clear Settings to Yes then press three times, “DONE” will be displayed. This will remove all of the previous Wi-Fi settings. Refer to the Wi-Fi Quick Start Guide for instructions on connecting to the thermostat to your Wi-Fi network.
The thermostat can only be registered to one my.aprilaire.com account. If you need to remove the thermostat from an existing account so it can be registered to a new account, it can be done at the thermostat. This may need to be done for instance if your have purchased a home with the thermostat and need to remove the thermostat from the previous owner’s account and register it to your account. To do this, enter the Wi-Fi settings menu as described in the Accessing Wi-Fi Settings Menu section on page 14. Change the setting for Unregister the Thermostat to Yes and then press twice, “DONE” will be displayed. This will remove the thermostat from any account that it is currently registered to. Refer to the Wi-Fi Quick Start Guide for instructions on registering the thermostat to a new my.aprilaire.com account.
To turn off the Wi-Fi radio on the thermostat, enter the Wi-Fi settings menu as described in the Accessing Wi-Fi Settings Menu section. Change the setting for Turn WiFi Radio On/Off to Off and then press , “DONE” will be displayed. This will turn off the Wi-Fi radio, but maintain all network settings. To turn the Wi-Fi radio back on simply enter the Wi-Fi setting menu and change the setting for Turn WiFi Radio On/Off to On and then press , “DONE” will be displayed.
The Wi-Fi connection status is communicated through the use of the radio strength indicator. The following table describes the various statuses and the corresponding radio bar display.
Your Research Products Corporation Aprilaire® Thermostat unit is expressly warranted for five (5) years from date of installation to be free from defects in materials or workmanship. Research Products Corporation’s exclusive obligation under this warranty shall be to supply, without charge, a replacement for any thermostat which is found to be defective within such five (5) year period and which is returned, together with the date of installation, no later than thirty (30) days after said five (5) year period by you to either your original supplier or to Research Products Corporation, Madison, Wisconsin 53701.
THIS WARRANTY SHALL NOT OBLIGATE RESEARCH PRODUCTS CORPORATION FOR ANY LABOR COSTS AND SHALL NOT APPLY TO DEFECTS IN WORKMANSHIP OR MATERIALS FURNISHED BY YOUR INSTALLER AS CONTRASTED TO DEFECTS IN THE THERMOSTAT ITSELF. IMPLIED WARRANTIES OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE SHALL BE LIMITED IN DURATION TO THE AFORESAID FIVE-YEAR PERIOD.
RESEARCH PRODUCTS CORPORATION’S LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, OTHER THAN DAMAGES FOR PERSONAL INJURIES, RESULTING FROM ANY BREACH OF THE AFORESAID IMPLIED WARRANTIES OR THE ABOVE-LIMITED WARRANTY IS EXPRESSLY EXCLUDED. THIS LIMITED WARRANTY IS VOID IF DEFECT(S) RESULT FROM FAILURE TO HAVE THIS THERMOSTAT INSTALLED BY A QUALIFIED HEATING AND AIR CONDITIONING CONTRACTOR. IF THE LIMITED WARRANTY IS VOID DUE TO FAILURE TO USE A QUALIFIED CONTRACTOR, ALL DISCLAIMERS OF IMPLIED WARRANTIES SHALL BE EFFECTIVE UPON INSTALLATION.
Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above exclusions or limitations may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
Visit us online at www.aprilaire.com to register your Aprilaire product. If you do not have on-line access, please mail a postcard with your name, address, phone number, product purchased and date of purchase to: Research Products Corporation, P.O. BOX 1467, Madison, WI 53701.Your Warranty Registration information will not be sold or shared outside of this company.
Compliance Statement (Part 15.19) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
Warning (Part 15.21)
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
To comply with FCC/IC RF exposure limits for general population / uncontrolled exposure, the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.
RSS-GEN, Sec. 7.1.2
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.
RSS-GEN, Sec. 7.1.3
Operation is subject to the following two conditions:
U.S. Patent Numbers 8,146,376, 8,596,078, and other patents are pending. © 2015 Aprilaire – A division of Research Products Corporation
Download Manual
Aprilaire 8476 Digital Programmable Thermosta with Wi-Fi Owner Manual
Aprilaire 8476 Digital Programmable Thermosta with Wi-Fi Owner Manual
OTHER MANUAL
Aprilaire 8476 Digital Programmable Thermosta with Wi-Fi Safety & Installation Instructions
Aprilaire 8476 Digital Programmable Thermostat with Wi-Fi Owner Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…