WARNING:
R, V-VR or VR-R | R | 24 VAC, Return |
Y, Y1 or M | Y | Stage 1 Cooling/Heating Circuit |
O or R | O | Reversing Valve, (Cooling Mode) |
B | B | Reversing Valve (Heating Mode) |
F or G | G | Fan control relay |
Y2 | Y2 | 2nd Stage Cooling Circuit |
W1 or W2 or W-U | W2 | 2nd Stage Heating Control |
L or X | L | System Monitor LED |
E | E | Emergency Heating Circuit |
C, X or B | C | 24 VAC, Transformer Common Side |
*NOTE: This thermostat requires a 24V common wire for proper operation.
*NOTE: This thermostat requires a 24V common wire for proper operation.
NOTE: For new installations, mount thermostat on inside wall, 4-5 feet above the floor. Do not install behind a door, in a corner, near air vents, in direct sunlight, or near any heat or steam generating fixtures. Installation at these places will affect thermostat operation.
Setting or Changing the Setpoint Temperature
iMPORTANT: The temperature differential is factory set at 1 (1°). This means that whenever the room temperature changes by one half of a degree from the temperature setting, the system will turn on. If the system turns on too often, increase the temperature differential.
WARNING: DO NOT SHORT (JUMPER) ACROSS TERMINALS OF GAS VALVE OR SYSTEM CONTROL TO TEST OPERATION. THIS WILL DAMAGE THE THERMOSTAT AND VOID YOUR WARRANTY.
CAUTION: Do not switch the system to cool if the temperature is below 50°F (10°C).
This can damage the air conditioning system and cause personal injury.
The thermostat is preset to display the temperature in degrees Fahrenheit.
You may change the display readout to Celsius if desired.
The LED indicators are used to indicate system activity. The AUX indicator illuminates during a call for second stage heating. The auxiliary stages are used to maintain comfort during extremes in weather conditions. If the AUX LED is illuminated too frequently during periods of moderate temperature, check the differential settings (page 6). The CHECK indicator is used to monitor system status. If the CHECK indicator is illuminated, call your local HVAC service provider. The EMER indicator is illuminated only when the system switch is moved to the EM, emergency heat position. The EM position is used only when the primary stage of heat is not functioning or requires service.
Symptom
The thermostat does not turn on the system.
Remedy
Check Wiring (see INSTALLATION). Check fuse. Replace with 2 amp fuse if fuse has opened.
Symptom
The thermostat turns on and off too frequently.
Remedy
Increase Temperature Differential (see DIFFERENTIAL).
Symptom
The system fan does not operate properly.
Remedy
Move the fan option switch to either gas or electric, to match system (see INSTALLATION).
Symptom
The thermostat does not display the proper room temperature.
Remedy
Check the “F” Fahrenheit /”C” Celsius switch located at the top center of the circuit board for proper position. If a new selection is made, press the “RESET” button located directly below LCD display.
If problems with the thermostat cannot be solved, call:
The following is just a sample of the most common types of HVAC systems. Refer to your systems installation manual for wiring information.
Your Research Products Corporation Aprilaire® Thermostat unit is expressly warranted for two (2) years from date of installation to be free from defects in materials and workmanship. Research Products Corporation’s exclusive obligation under this warranty shall be to supply, without charge, a replacement for any thermostat which is found to be defective within a two (2) year period and which is returned, together with the date of installation, no later than thirty (30) days after said two (2) year period by you to either your original supplier or to Research Products Corporation, Madison, Wisconsin 53701.
THIS WARRANTY SHALL NOT OBLIGATE RESEARCH PRODUCTS CORPORATION FOR ANY LABOR COSTS AND SHALL NOT APPLY TO DEFECTS IN WORKMANSHIP OR MATERIALS FURNISHED BY YOUR INSTALLER AS CONTRASTED TO DEFECTS IN THE THERMOSTAT ITSELF.
IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL BE LIMITED IN DURATION TO THE AFORESAID TWO YEAR PERIOD. RESEARCH PRODUCTS CORPORATION’S LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, OTHER THAN DAMAGES FOR PERSONAL INJURIES, RESULTING FROM ANY BREACH OF THE AFORESAID IMPLIED WARRANTIES OR THE ABOVE LIMITED WARRANTY IS EXPRESSLY EXCLUDED. THIS LIMITED WARRANTY IS VOID IF DEFECT(S) RESULT FROM FAILURE TO HAVE THIS THERMOSTAT INSTALLED BY A QUALIFIED HEATING AND AIR CONDITIONING CONTRACTOR. IF THE LIMITED WARRANTY IS VOID DUE TO FAILURE TO USE A QUALIFIED CONTRACTOR, ALL DISCLAIMERS OF IMPLIED WARRANTIES SHALL BE EFFECTIVE UPON INSTALLATION. Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above exclusion or limitations may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
DOWNLOAD MANUALS:
Aprilaire 8336 DIGITAl ELECTRONIC THERMOSTATS Installation and User Instructions
Aprilaire 8336 DIGITAl ELECTRONIC THERMOSTATS Installation and User Instructions
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…