WUNDATRADE

WUNDATRADE E02 Touch Screen Programmable Thermostat User Manuals

WUNDATRADE E02 Touch Screen Programmable Thermostat

Over View

Set the time and day of the week
Press the clock symbol for 5 seconds. The minutes will start flashing – use the up down symbols to change minutes as required and confirm your choice by pressing thesymbol
The hour will now flash, repeat the same process to adjust and confirm by pressingthe key. A number between 1 to 7 will now start flashing on the left-hand side of the screen
1 = Monday, 7 = Sunday. Use the up down symbols to change as required and confirm your choice by pressing the symbol. The time and day are now set.

Second Choose either a 5, 6 or 7-day cycle
The programmer offers you the choice of 6 heating events each day of the week with the choice of different temperatures in each event – either for 5 days of the week plus all-day heating on days 6 and 7 (the weekend) with two heating events.
OR the same on/off timing for days 1 – 6 plus day 7 with all-day heating.
OR the same 6 heating events for all 7 days. The programmer is set at the factory for the 5 plus 2 cycles.

Copying the 1- 5 settings for 6 or all 7 days
PRESS TO TURN OFF then pressand menusymbol together you are now in advanced settings. Now press menusymbol 5 times to display PrG – you can now set days 6 or days 6 & 7 to be the same as days 1- 5 by pressing arrow symbols. When the screen shows day 6 with days 1 – 5 OR days 6 & 7 with days 1- 5 you are finished. Switch the unit OFF and back ON to return to the main screen by pressing symbol.

Setting Thermostat

To start programming press the menusymbol for 5 seconds – the sunsymbol will appear on the left-hand side of the screen together with the time that the first event will start. You can change the time by using the up and downsymbols as required and confirm by pressing the menusymbol.
Next is the temperature you require during the first heating event session – use the up and down arrow symbols until satisfied and then confirm by pressing the menusymbol. There are 6 heating event times to input and 6 temperature settings to confirm – if you make a mistake press the menusymbol repeatedly and go through the complete cycle again until you return to the required place.

Function

Manual override mode

press menusymbol until handsymbol appears. The scheduled period is overridden, set the temperature to your individual requirements using arrow symbols and the thermostat will operate at this temperature permanently.

Clock controlled program mode
To exit the manual override press menu symboluntil clock symbol appears. The thermostat will operate automatically according to the programmed temperature and time.

single period manual override comfort mode 

While in clockcontrolled mode press arrow symbols until the clockand handsymbols appear together. This enables you to manually override the scheduled heating event’s temperature setting, so the temperature can be temporarily changed for a single heating event, the ‘comfort mode’ temperature is reset at the next heating event when the thermostat will return to the scheduled program.

Keylock function.
Once thermostat has been programmed, pressarrow symbols together for 5 seconds to lock the touch screen, and the keylock symbolwill be displayed. Repeat these steps to unlock touch screen.

Programming: 6 heating event Time & Temperature

Please note:
If using an external floor probe to limit floor temperature, then advanced settings ‘SENSOR MODE’ must be set to ‘ALL’ and the ‘ADJUST LIMITATION TEMPERATURE VALVE’ be set to the desired limit temperature, i.e. 270C for wood flooring.

Advanced settings: Turn the thermostat OFF by pressing the ON/OFFsymbol. Then press and holdmenu symbol while turning the thermostat back on (by pressing symbol once) until the thermostat enters the ‘advanced settings’ mode. Press menusymbol to advance to the required function. Press ymbols to change individual function settings. To save settings and EXIT this mode, press ON/OFFsymbol.

Key/ symbol to open No. of times to press Symbol Function

 

 

 

 

 

 

 

 

 

 

1 1Adj 1 Adj Measured temperature display and adjustment

Adjusts current measured temperature value. Range +/- 9.9O C

2 2SEN

2SEN

Sensor selection

IN     : Built in sensor – shows & ONLY measures air temp

OUT : Floor sensor – shows & ONLY measures probe temp (can be in floor or probe housing)

ALL : Both sensors – shows air temp or set probe temperature (used as a max temperature for floors – floor sensor is limiter)

3 3Lir 3LIT Adjust limitation temperature value Adjust limitation value range 5 – 60OC (Probe limit temperature, i.e. 270C for wood floors)
4 4diF 4diF Switching differential Adjusts switching differential setting range 0.5 – 10OC
5 5Lrp 5LTP  Enabling/disabling frost setting when unit is off

Switches frost setting function ON/OFF

6 6PrG 6PRG Daily timer sequence Selects 5/2 day mode, 6/1 day mode, 7 day mode OR OFF

7

7rLE

7RLE Not available on this model. Potential free output and main output synchronous/ asynchronous direction

Do not adjust

KEEP FACTORY SETTING = 00

8 8dLy 8DLY Not available on this model. Potential free time lapse output time Do not adjust

KEEP FACTORY SETTING = 0

9

9Hri

9HIT Max temperature setting value

Adjusts maximum temperature setting value from 35 – 90OC

10

AFAC

AFAC Reset to factory settings

Presskey for 5 seconds until ’- – -’ is shown to restore factory settings

NOTE: If “ERR” is displayed on the screen when the thermostat is first turned on – enter advanced settings (as described above) and advance to function “2SEN” . Press symbol so that “IN” reads on the screen. Switch the unit OFF and back ON to clear and the thermostat will return to normal working.
Most other adjustments should be made by a qualified person

Tech support opening hours are subject to change – please visit our website for the latest information
www.wundatrade.co.uk
0800 083 2677

Reference

Download Manual:

WUNDATRADE E02 Touch Screen Programmable Thermostat User Manuals

WUNDATRADE E02 Touch Screen Programmable Thermostat User Manuals

 

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

1 year ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

1 year ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

1 year ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

1 year ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

1 year ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

1 year ago