WARNING!
The thermostat must be installed by a qualified electrician in accordance with National Electrical Code.
Wiring Connections
LOAD L1 & L2 | Heater Load Max.15A (1800W – 120V, 3600W – 240V) |
LINE L1 | Supply Live (120 V) |
LINE L2 | Supply Neutral (120 V) / Supply Live (240 V) |
P1 & PC | Probe 1 – Floor/Air Control Sensor (No Polarity) Floor or air temperature reading for scheduled control |
P2 & PC | Probe 2 – Limit Sensor (No Polarity) |
See Table 1.0 for thermostat use cases |
NOTE: The function of Probe 1, Probe 2 from Control/Limit Sensor can be swapped in settings.
Table 1.0 Thermostat Use Cases
Heating loads connected to thermostat
Option 1 | Heating ≤ 3600W / 15A into thermostat only R C Snubber not required |
| RED – Hot 120V / White – Neutral |
| Heating, RED – 240V, Yellow – 120V |
Heater earth connections should be connected to earth in line with NEC, CEC code.
Heating loads connected to Relay-25
Option 2 Heating ≤ 3600W / 15A into external relay only R C Snubber required
Heater earth connections should be connected to earth in line with NEC, CEC code.
Heating loads connected to thermostat and Relay-25
Option 3
Heating ≤ 3600W / 15A into thermostat
Heating ≤ 3600W / 15A into external relay Additional relays can be added to circuit as shown R C Snubber required
Heater earth connections should be connected to earth in line with NEC, CEC code.
How to quickly change the temperature
Press
If in manual mode this will set a fixed target temperature. See “How to set into Manual Mode”
Once the target temperature is set above current floor/air temperature the heating indicator (
How to quickly change mode
Mode select allows you to quickly change from manual mode, program mode or simply switch the heating off.
How to set a program
Setting a program allows you to set comfort temperatures at set times throughout the day. Days can programmed individually, all days the same or weekdays as a block and weekends as a block, the choice is yours.
How to set into Manual Mode
Setting into manual mode allows you to set a fixed target temperature for the thermostat to achieve. The thermostat will continue to maintain this temperature until another operating mode or temperature is selected.
How to set a Temporary Override
Setting a temporary override allows you to set a target temperature which will override your current heating program until your next heating period or for a set duration.
How Energy Monitor works
The thermostat learns how you use your system and how your house reacts to heating and weather. Using the MyHeating App, energy monitoring will show the amount of energy consumed over a certain time period. This will be calculated through system power multiplied by efficiency and run time.
You will need to enter the power of your system, and in some cases, the efficiency. If you do not know these, speak to your installer or system manufacturer.
How SmartGeo works
SmartGeo is a unique technology developed by Warmup and built into the MyHeating App that uses an advanced algorithm to understand the most efficient heat settings for your home.
Working automatically; it learns your routines and location through background communication with your smartphone and lowers temperatures when you are away, only rising them up to your ideal comfort temperature in time for your arrival home.
Smartgeo will operate when the thermostat is in the program or manual run modes. It is turned off by default. Use the MyHeating App to switch SmartGeo on.
Display is blank | Power | (Electrician Required) Electrician required to verify power is going to the thermostat and that it is correctly wired. |
Control (5 & 6) / Internal Air sensor error | 1. Please see Table 1.0 and ensure you have selected the correct thermostat application. 2. (Electrician Required) Electrician required to verify that the floor sensor has been wired correctly. If it is correctly wired the electrician will need to check the resistance of the floor sensor using a multi meter. For temperatures between 68°F – 86°F the resistance of the floor sensor should measure between 8K ohms and 12K ohms. If the electrician finds a fault, and the thermostat is in the room to be heated then it can be set into “Air Mode”. To set into “Air Mode”, see Table 1.0 Thermostat application. If “—” still remains when set into air mode the thermostat will have to be replaced. | |
Limit Sensor Error (6 & 7) | ||
Heating is coming on earlier than programmed times | Adaptive learning (Early start) On | Adaptive learning (Early start) will use the historic heating/cooling rates for the time of day, historic external temperatures and the forecast external temperatures, to work out the heating start time in order to reach the comfort time at the start of the comfort period. It will only work in Program Mode. |
WiFi Error Symbol | WiFi not setup | 1. Download and open the MyHeating App 2. Remove thermostat from the wall 3. Scan QR code on the back of the display 4. Place thermostat back on the wall and power-up 5. Thermostat will be in pairing mode for 1 minute. App should automatically connect to phone 6. Follow instructions in App |
WiFi disconnected | Follow the step above to try and to re-connect to the WiFi Network. If the thermostat still fails to connect, see WiFi Troubleshooting. |
Clock Icon | Time and Date not set | Connect the thermostat to a WiFi network or alternatively set the time and date from the settings menu. |
GFCI Icon | GFCI test button | The GFCI feature is used to detect any leakage of current from your heating system. During a ground fault the two lines of the load will be cut off. Once your thermostat is installed and connected to a power supply you can test the GFCI function by increasing the set temperature until heating is on – the heat up icon ( If your test is successful you will see the GFCI error icon and you will need to hold “X” for 3 seconds in order to restore heating operation. |
Heater error | The GFCI has tripped due to a fault in the heater. (Electrician Required) Electrician required to verify that the heater has been wired correctly. If correctly wired please conduct a resistance test and insulation resistance test on the heater to see if damage has occurred. | |
Relay icon
| Relay error | The thermostat has detected that one of the relays has FAILED. Please contact Warmup |
Before following the troubleshooting guide below please check the following:
Model | RSW-XX-YY-ZZ |
Operating Voltage | 110V – 240V AC +/-15% 50Hz/60Hz |
Protection Class | II |
Max. Load | 15A resistive (120 V – 1800W, 240 V – 3600W) |
GFCI | Class A GFCI with 5mA trip level |
Rated impulse voltage | 4000V |
Automatic action | 100,000 |
Disconnection means | 1B |
Pollution degree | 2 |
Max. Ambient Temperature | 40°C / 104°F (T40) |
Relative Humidity | 80% |
IP Rating | IP30 |
Sensors | Floor/Air |
Sensor Type | NTC10K @ 25°C |
Operating Frequency | 2401 – 2484MHz |
Max. Radio-Frequency Power Transmitted | 20dBm |
Compatibility | Electric Floor Heating and Baseboard Heating |
Standards | UL-60730-1 UL-60730-2-9 UL-943 CAN/CSA-E60730-1 CAN/CSA-E60730-2-9 CAN/CSA-C22.2 No. 144.1 FCC 47 CFR Part 15, ICES-003 |
Warranty | 12 Years |
Approvals | ETL Intertek |
Warmup warrants this product, to be free from defects in the workmanship or materials, under normal use and service, for a period of twelve (12) years from the date of purchase by the consumer when installed with a Warmup heater. If at any time during the warranty period the product is determined to be defective, Warmup shall repair or replace it, at Warmup’s option. If the product is defective, please either;
Return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it, or Contact Warmup. Warmup will determine whether the product should be returned or replaced.
The twelve (12) year warranty only applies if the product is registered with Warmup within 30 days after purchase. Registration can be completed online at www.warmup.com.
This warranty does not cover removal or re-installation costs and shall not apply if it is shown by Warmup that the defect or malfunction was caused by failure to follow the instruction manuals, incorrect installation or damage which occurred while the product was in the possession of a consumer. Warmup’s sole responsibility shall be to repair or replace the product within the terms stated above. If the thermostat is installed with a non-Warmup heater a three (3) year warranty will apply. This warranty does not extend to any associated software such as apps or portals.
WARMUP SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. THIS WARRANTY IS THE ONLY EXPRESS WARRANTY WARMUP MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE TWELVE-YEAR DURATION OF THIS WARRANTY.
This warranty does not affect your statutory rights.
Warmup Inc
www.warmup.com
ussales@warmup.com
T: (888) 927-6333
Warmup Canada
ca@warmup.com
T: (888) 592-7687
Download Manual
WARMUP TRA-04-WH-LC Terra Smart Series Wi-Fi Thermostat User Guide
WARMUP TRA-04-WH-LC Terra Smart Series Wi-Fi Thermostat User Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…