This quick start guide will get your hUFH, radiator and DHW system operational with minimal fuss by focusing solely on its core functions.
IMPORTANT:
Warmup konekt Wireless Smart Hub | |
The Smart Hub is the central unit of the Warmup Kontakt Wireless System. It connects smartphones via the Warmup App and transmits configuration data and control commands from the App to all Warmup Konekt Wireless devices. | |
Product Code | KW-UKHUB |
Operating Voltage | 100 – 240 V AC / 50 Hz |
Supply Voltage | 5 VDC |
Current Consumption | 500 mA max. |
Power Consumption, Plug-in Mains Adapter | 2.5 W max. |
Standby Power Consumption | 1.1 W |
IP Rating | IP20 |
Ambient Temperature | 5 to 35 °C |
Dimensions (W x H x D) | 118 x 104 x 26 mm |
Weight | 153 g |
Radio Frequency Band | 868.0-868.6 MHz, 869.4-869.65 MHz |
Maximum Radiated Power | 10 dBm max. |
Receiver Category | SRD category 2 |
Type Open Area RF Range | 400 m |
Duty Cycle | < 1 % per h/< 10 % per h |
Network | 10/100 MBit/s, Auto-MDIX |
Warmup konekt Wireless eTRV | |
The eTRV offers modulating time and temperature control of rooms heated with radiators. Can be used with other devices to create a connected multi-zone system. Use in conjunction with the Thermostat for more accurate temperature regulation. The eTRV fits to all common radiator valves and is easy to mount – without having to drain any water or intervene in the heating system. | |
Product Code | KW-UKETRV |
Supply voltage | 2x 1.5 V LR6/mignon/AA |
Current consumption | 100 mA max. |
Battery life | 2 years (typ.) |
IP Rating | IP20 |
Ambient temperature | 0 to 50 °C |
Dimensions (W x H x D) | 56 x 115 x 67 mm |
Weight | 180 g (incl. batteries) |
Radio-frequency band | 868.0-868.6 MHz, 869.4-869.65 MHz |
Maximum radiated power: | 10 dBm |
Receiver category | SRD category 2 |
Typ. open area RF range | 250 m |
Duty cycle | < 1 % per h/< 10 % per h |
Software class | Class A |
Method of operation | Type 1 |
Degree of pollution | 2 |
Valve Connection | M30 x 1.5 mm |
Warmup konekt Wireless Thermostat with Humidity Sensor | |
The thermostat offers precise time and temperature control of floor heating or radiator systems when combined with the Wiring Centre or ATVs. The Thermostat measures both temperature and humidity in a room. | |
Product Code | KW-STATE |
Supply Voltage | 2x 1.5 V LR03/micro/AAA |
Current consumption | 50 mA max. |
Battery life | 2 years (typ.) |
IP Rating | IP20 |
Ambient temperature | 0 to 35 °C |
Dimensions (W x H x D) | 55 x 55 x 23.5 mm / 86 x 86 x 25 mm (incl. frame) |
Weight | 100 g (incl. batteries) |
Radio Frequency Band | 868.3 MHz / 869.525 MHz |
Maximum Radiated Power | 10 dBm max. |
Receiver category | SRD category 2 |
Typ. open area RF range | 250 m |
Duty cycle | < 1 % per h/< 10 % per h |
Method of operation | Type 1 |
Degree of pollution | 2 |
Warmup konekt Wireless 10-Channel Wiring Centre 230V | |
The Wiring Centre provides UFH circulator and actuator control based on room, heating/ cooling demand. It can control up to 10 heating zones/15 actuators or 14 actuators with a UFH circulator. It can be mounted using the screws supplied or on a DIN rail. | |
Product Code | KW-WC10CH |
Supply voltage | 230 V AC / 50 Hz |
Current consumption | 6.3 A max. |
IP Rating | IP20 |
Protection class | I |
Ambient temperature | 0 – 50°C |
Type | 1.B. |
Dimensions (W x H x D) | 225 x 75 x 52 mm |
Weight | 566 g |
Radio frequency band | 868.0-868.6 MHz, 869.4-869.65 MHz |
Maximum radiated power | 10 dBm |
Receiver category | SRD category 2 |
Typ. open area RF range | 270 m |
Duty cycle | < 1% per h/< 10% per h |
Construction | independently mounted electronic regulation and control device, surface mount |
Number of heating zones | 10 |
Number of actuators | 15 / (14) |
Number of pumps | 1 |
Switching capacity per heating zone | 1 A max. |
Nominal load of all actuators | 250 W max. |
Type of disconnection | micro |
Cable type and cross section | Rigid, flexible cable, 0.75-1.5 mm² |
Cable cross section of cable bushing 1 | > 5.2 mm |
Cable cross section of cable bushing 2 | > 8.2 mm |
Cable cross section of cable bushing 3 | > 3.2 mm |
Withstand voltage | 2500 V |
PTI value of housing | IIIb with 100 < CTI < 175 |
Warmup konekt Wireless Boiler 2-Channel Switch | |
Provides interlock for: • UFH demand • Radiator demand • DHW scheduling • Heating and Cooling changeover • Dehumidification demand Where more than 2 channels are required multiple switches can be used. | |
Product Code | KW-BLR2CH |
Operating Voltage | 230 V AC / 50 Hz |
Current Consumption | 16 A max. |
Standby Power Consumption | < 0.2 W |
IP Rating | IP20 |
Protection Class | I |
Ambient Temperature | 0 to 50 °C |
Load Type | Ohmic load |
Max. Switching Capacity Switching Channel 1 Switching Channel 2 | 16 A (3680 W) 5 A (1150 W) |
Method of Operation | 1.B |
Cycle Rating | 10,000 |
Relay | Changeover contact: 1-pole, µ contact NO contact: 1-pole, µ contact |
Withstand Voltage | 2500 V |
Radio frequency band | 868.0-868.6 MHz, 869.4-869.65 MHz |
Maximum radiated power | 10 dBm |
Receiver category | SRD category 2 |
Typ. open area RF range | 250 m |
Duty cycle | < 1% per h/, < 10% per h |
Construction | Independently mounted electronic regulation and control device |
Degree of Pollution | 2 |
Saftey Information
Smart Hub
eTRV
Please note that the room temperature control via the eTRV is designed for a two pipe heating system with one feed and return line per radiator. Use in single-pipe heating systems can lead to strong deviations in the set temperature due to fluctuations in the flow temperature.
The duty cycle is a legally regulated limit of the transmission time of devices in the 868 MHz range. The aim of this regulation is to safeguard the operation of all devices working in the 868 MHz range. In the 868 MHz frequency range we use, the maximum transmission time of any device is 1% of an hour (i.e. 36 seconds in an hour). Devices must cease transmission when they reach the 1% limit until this time restriction comes to an end. Warmup devices are designed and produced with 100% conformity to this regulation. During normal operation, the duty cycle is not usually reached. However, intensively repeated device teach-in processes may mean that this limit is reached in isolated instances during commissioning. If the duty cycle limit is exceeded, the device may stop working for a brief period. The device will start working normally again after a short period (max. 1 hour).
General information about radio operation
Radio transmission is performed on a non-exclusive RF channel, which means that there is a possibility of interference occurring. Interference can also be caused by switching operations, electrical motors or defective electrical devices.
The range of transmission within buildings can differ greatly from that available in the open air. Besides the transmitting power and the reception characteristics of the receiver, environmental factors such as humidity in the vicinity have an important role to play, as do on-site structural/screening conditions
Declaration of Conformity
Warmup hereby declares that the Warmup konekt Wireless radio equipment is compliant with Directive 2014/53/EU. Please scan the QR Code for the Declaration of Conformity
Instructions for Disposal
Do not dispose of the device(s) with regular domestic waste! Electronic equipment must be disposed of at local collection points for waste electronic equipment in compliance with the Waste Electrical and Electronic Equipment Directive.
Warmup plc warrants theses product(s), to be free from defects in the workmanship or materials, under normal use and service, for a period of three (3) years from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defective, Warmup shall repair or replace it, at Warmup’s option. If the product is defective, please either; Return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it, or Contact Warmup. Warmup will determine whether the product should be returned or replaced. This warranty does not cover removal or re-installation costs and shall not apply if it is shown by Warmup that the defect or malfunction was caused by failure to follow the instruction manuals, incorrect installation or damage which occurred while the product was in the possession of a consumer. Warmup’s sole responsibility shall be to repair or replace the product within the terms stated above.
WARMUP SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. THIS WARRANTY IS THE ONLY EXPRESS WARRANTY WARMUP MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE THREE-YEAR DURATION OF THIS WARRANTY.
This Warranty does not affect your statutory rights
Sybmols Used
DOWNLOAD MANUALS:
Warmup KW-STATH WIRELESS Thermostat Quick start guide
Other manuals:
Warmup KW-STATH WIRELESS Thermostat Installation guide
Warmup KW-STATH WIRELESS Thermostat Product Specification Sheet
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…