Please visit www.warmup.com (US) and www.warmup.ca (CAN) for videos, specification sheets, and complete wiring and mounting instructions.
Step 1 – Note your Device Number
On first power up the 4iE will display the Device Number. Make a note of this number as it will be needed when registering the 4iE online. If you lose this number you can find it once the 4iE has been set up by going to settings, advanced settings, about and info.
Step 2 – Setting Up Your Thermostat
After you have noted your device number you need to set up your 4iE.
NOTE: When the reset has been pressed, the time for a reset will need 5 ~ 15 seconds.
Step 3 – Go to my.warmup.com
Now that the 4iE has been set up you will need to register your device online. Go to my.warmup.com and click register. Enter the password and email address you would like the MyWarmup account to be linked to and click register. Check your email account for a verification email from Warmup. You can now log into my.warmup.com. When logged in you will have to register your 4iE device number in order to connect to our server. Go to the homepage and click the add room icon at the bottom of the page. Enter in all the details required, including the 4iE device number, and click register. You will now be able to control your heating through the my.warmup.com webpage.
Try to reconnect to the WiFi again. Go to menu, settings and network and re-enter your password. Remember the SSID must be less than 11 characters and the password must be less than 10 characters for a successful connection. If you still cannot connect to your WiFi network contact Warmup on US: at (888) 927-6333 or Canada: (888) 592-7687.
Ensure you have visited my.warmup.com and registered your 4iE’s device number. To find your device number press menu, settings, advanced settings, about and info. Log into my.warmup.com, click a room, add room, and click full registration. Enter in all details requested including device number and register. You will now connect to the server.
If after registering the symbol is still displayed please contact Warmup in US: (888) 927-6333 or Canada: (888) 592-7687.
Supply Voltage | 120-240V, AC +10% / -15%, 60Hz |
Maximum Switch Load | 15A Note: This product is not designed to be used with any inductive load |
GFCI | Class A GFCI with 5mA trip level |
Temperature Display Range | +32°F to 122°F (0°C to +50°C) |
Operating Temperature | +32°F to 104°F (0°C to 40°C) |
Storage Temperature | -4°F to 140°F (-20°C to +60°C) |
Dimensions | 90 x 120 x 21.7mm (2-3/4” deep double gang box recommended) |
Floor Senor Type | NTC (10K) |
IMPORTANT NOTICES
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Caution: To maintain compliance with the RF exposure guidelines, place the unit at least 20cm from nearby persons.
IC Statement
This device complies with Industry Canada Licence-exempt RSS-247. Operation is subject to the following two conditions:
Caution: To maintain compliance with the RF exposure guidelines, place the unit at least 20cm from nearby persons.
4iE Setup
How does the 4iE connect to the Internet?
It connects through WiFi to your router. You will find your network on the screen and enter the password like you would on a smartphone.
What type of security is used with my data?
The 4iE and MyWarmup servers communicate using AES128 encryption with SHA256 hashing. My.warmup.com is protected using SSL technology – the same type used with online banking.
Does the 4iE work over 3G?
Both your 4iE and the device you are using to control it (iPad, smartphone, laptop etc.) need to be connected to the internet. They do not need to be connected to the same WiFi network. For example, your 4iE can be connected to your home internet network and your smartphone can be connected to a different 3G network whilst you’re out and you’ll be able to control your 4iE remotely.
How do I set the 4iE to program itself?
The 4iE requires 2 weeks of use to accurately learn your schedule and temperatures. Go to my.warmup.com and in the Schedule tab (within Rooms), select your thermostat and select ‘Auto Schedule’.
How do I add a custom background?
On the home page of my.warmup.com, click on the green ‘Room Settings’ icon in the top right corner of the selected room. Within the section called custom background, you can upload an image. This can take approximately 10 minutes for the thermostat to upload. To change the background from your 4iE, select menu, and settings and then go to display & audio. Go to the background and choose uploaded.
Network icon with ‘X’ displayed on the screen
My SSID is less than 11 characters but still won’t connect to the Internet?
Check you are using a WPA2 password format (less than 10 characters) on your network. WEP is an outdated password format that is no longer considered secure – the 4iE will not connect using a WEP password format. For details on how to change your password format please contact your Internet supplier or router manufacturer. Warmup cannot advise on specific router types due to the varied range available.
My SSID is less than 11 characters and my password is WPA2, but my 4iE still won’t connect to the Internet.
You may have problems with your router or a firewall in place that is preventing a successful connection. Please contact Warmup with details of your system setup (please do not send us your network passwords), including router model, internet supplier and any 3rd party firewall and antivirus software you have installed and we will investigate your problem.
Connection Troubleshooting
Network icon with ‘!’ displayed on the screen
I’ve registered an account and my 4iE but still have an ‘!’ on the screen You may be running an old software version on your 4iE that needs to be updated. Please reset your 4iE (found in the settings menu, under advanced settings). Once it’s reconnected please contact us with details of your account, email address and thermostat name so that we can ensure you have the latest software.
I have registered an account and my 4iE, and I have the latest software but still have an ‘!’ on the screen.
You may have problems with your router or a firewall in place that is preventing a successful connection. Please contact Warmup with details of your system setup (please do not send us your network passwords), including router model, internet supplier and any 3rd party firewall and antivirus software you have installed and we will investigate your problem.
Download Manual:
Warmup 4iE SMART WIFI THERMOSTAT Setup Guide
OTHER MANUALS:
Warmup 4iE SMART WIFI THERMOSTAT Installation Manual
WARMUP 4iE Smart WiFi Thermostat Troubleshooting Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…