Your thermostat’s default screen is the Home Screen. This screen displays important information such as the time, current floor and air temperature as well as the target set temperature. From this page, you can either access the “MENU” page (press “menu”) or override the currently programmed temperature (press “
Hint: You will often find a “help” button on pages with several options. Press the help button for more information on the options available.
If you do not press any button on the thermostat for 1 minute, then it will go to standby mode. In standby mode, the screen will be dimmed but the thermostat will continue to function as normal. To exit standby mode press “wake” (
On initial power up the thermostat will guide you through set up procedure for the following:
By accessing the main menu you can program your thermostat or make any changes to the settings. To access the menu press “menu” on the main screen. If the thermostat is in sleep mode, press ”wake”.
Press “menu”, then Press “set program”Press the programming option that suits your needs.
Press “up” or “down” to set the start time for the first of the day.
Note: if you hold a button for several seconds it will scroll continuously until you release your finger.
To change the target floor temperature, press “floor temp”, you can now press “up” and “down” to change the target floor temperature.
Note: If you would rather use your thermostat to target an air temperature, please read the “SETTINGS” section of this document.
If you want the target temperature to change later on in the day then press “add another period”. You can add up to 10 periods in each day.
Note: It is recommended that you finish your daily program on a low target temperature so that you save energy overnight.
Note: If you do not need the heating to protect against frost, then you can scroll down to the bottom of the temperature range to set the target temperature to “OFF”. With this setting, the heating will not come on regardless of the temperature. Once you have set all the desired periods in the daily press “done” to go to the summary page. This summary page allows you to see the program you have set for this day. If you need to change something press “edit”. This will take you back to the first period of the day. Remember that you will need to add all the periods again.
If you are happy with the program and would like to set the same program for the following day press “copy today” If you are happy with the program but would like to set a different program for the following day press “OK” If you would like to return to the preceding day press “back”. When you have set a program for all the days including Sunday (or Weekend in the case of Weekday/ Weekend) then pressing “OK” will enter the schedule and return you to the home screen.
Note: The set temperature for the time before the first period of the day comes from the night before. 3iE Operating Guide V5 © Warmup plc – 2015
If you are using your 3IE thermostat to control heating in the bathroom, bedroom, kitchen, or living room then the pre-set schedules might help you set a program appropriate for you. Just select the desired pre-set room and everything is done automatically.
Hint: If you have used a pre-set schedule but want to make some changes, use the edit schedule function explained in the “Viewing and Editing a Schedule” section.
PRE-SET PROGRAMS TABLE
Time | Bathroom OC F loor Temp |
Time | Kitchen OC F loor Temp |
Time | Bedroom OC F loor Temp | Living Room OC Time F loor Temp | |||||
Mon-Fri | |||||||||||
06:00 | 25 | 06:00 | 23 | 06:00 | 25 | ||||||
08:00 | 10 | 08:00 | 10 | 08:00 | 10 | ||||||
19:00 | 20 | 18:00 | 23 | 20:00 | 20 | 18:00 | 23 | ||||
23:00 | 15 | 22:00 | 10 | 23:00 | 10 | 21:30 | 10 | ||||
Sat-Sun | |||||||||||
07:00 | 25 | 07:00 | 23 | 06:00 | 25 | ||||||
11:00 | 18 | 11:00 | 18 | 08:00 | 10 | 08:00 | 23 | ||||
18:00 | 20 | 18:00 | 23 | 20:00 | 20 | 18:00 | 20 | ||||
23:00 | 15 | 22:00 | 10 | 23:00 | 10 | 20:00 | 10 |
If you would like to view or edit the time and temperature settings of each day then press “view/edit program”
Hint: If you want to change the settings of multiple days it might be easier to
set a new program using the “set program” option
Press “up” and “down” until the day that you would like to view is highlighted, then press “OK” to view that day.
To exit the “VIEW / EDIT PROGRAM” menu page press “back”. Note that if you have edited any days these changes will be saved.
Here you can view the heating schedule for the selected day. If you would like to change any of the heating periods press “edit”. Remember that you will have to set all the heating periods.
You can view the schedule for the following day by pressing “view day”
To return to the day selection page press “OK”
HOLIDAY MODE allows you to override your schedule with a fixed temperature for a prolonged period of time. This can help save energy if you know that you will be out of the house and require minimal heating.
Press the highlighted button next to “holiday mode” to access the menu. Press “up” or “down” to set the first day you would like HOLIDAY MODE to start. Press “holiday end at” and then press “up” or “down” to set the day when you would like holiday mode to stop. At the end of the HOLIDAY MODE, your program will return to its current settings. If you would like HOLIDAY MODE to continue indefinitely, leave the end date as “not specified”. Press “holiday temperature” to set the fixed temperature that will be held for the entire HOLIDAY MODE period. Pressing “OK” will confirm the selection and HOLIDAY MODE will start at 12:00 pm on the specified date. During the HOLIDAY MODE, you will have a modified home screen. To cancel the HOLIDAY MODE at any time just press “cancel”. If you want to return to HOLIDAY MODE you will need to set it again.
Your thermostat monitors the amount of energy your underfloor heating system is using, you can use these pages to view the amount of energy used and set parameters to determine the cost of that energy.
To access this menu press “energy monitor” To view your energy usage, you will need to enter the total power in watts of the underfloor heating system connected to the thermostat. The energy usage will only be accurate AFTER you set the load settings. If you are unclear about the power of your underfloor heating then contact your installer To see how much energy you have used, select “view energy use” and then select the time period you would like to review. On the graph, each red bar indicates a time period (in this case it is months). The height of the bar indicates the amount of energy in KWH used by the underfloor heating system during that period. The bar in the far right is the most recent time period and the bar on the far left is the oldest. The total amount of energy used in the entire time span is displayed in the bottom bar
Press “OK” to return to the ENERGY MONITOR page.
Hint: if you are interested in seeing how much energy you can save by adjusting the settings of your thermostat, simply alter your heating program and wait a few days before comparing the daily energy used before and after you changed your program. To view the estimated cost of your energy usage, you will need to set the cost parameters in “energy settings”. The cost estimate will only be accurate for the time period AFTER you set the heating costs.
Select the appropriate structure that applies to your electricity tariff plan For both the standard and low energy tariff you will need to set a cost per Kilowatt-hour (KWH). First set the relevant currency by pressing “up” and “down” (you can select £, $, € and Y). Press “ok” to proceed to the first digit of the energy tariff, press “up” and “down” to select the correct amount and then press “ok” to proceed to the second digit. Continue pressing “ok” until you have set all the digits and returned to the ENERGY MONITOR main page. Hint: If your energy cost is 11.6 pence per kWh then you will need to set your cost per KWH to £0.116
If you are setting a “standard/ low energy tariff” you will also need to set the time of day at which the low energy tariff starts and stops and the cost per KWH during the low tariff period. After all these parameters are set you can view the cost of the energy used by your underfloor heating system in “view cost estimate”. If you are using “standard/low energy tariff” then the amount/ cost of energy used in the standard period will be displayed in red and the amount/ cost used in the low period will be displayed in white.
Your 3IE is a very flexible device and be configured in many different ways to meet your requirements. Functions that can be accessed in the “settings” menu include: “Time”
“Advanced settings”
WARNING!! The options in this section can affect the performance of your thermostat and should only be modified by an experienced underfloor heating installer or under the instruction of Warmup technical support
Your thermostat is capable of using a floor temperature sensor, air temperature sensor or both for thermal regulation. If you are using your underfloor heating as a secondary heating source (such as in the bathroom) then you might prefer to use the floor temperature. However, if the underfloor heating is the primary heating source in your home you might prefer to use the air temperature. “set floor temperature”
ADVANCED SETTINGS
WARNING!!
The options in this section can affect the performance of your thermostat and should only be modified by an experienced underfloor heating installer or under the instruction of Warmup technical support.
Programmable Limit °C | Overheat Limit °C | ||||
Air | Floor | ||||
Min. Temp | Max. Temp | Min. Temp | Max. Temp | ||
Tiles | 5 | 30 | 5 | 40 | 40 |
Stone | 3 | 30 | 5 | 40 | 40 |
Laminate | 2 | 27 | 5 | 27 | 30 |
Wood | 2 | 27 | 5 | 27 | 30 |
Carpet | 2 | 27 | 5 | 27 | 30 |
Vinyl | 5 | 27 | 2 | 27 | 30 |
Regulator | 5 | 30 | n/a | n/a | n/a |
User defined | User defined | User defined | User defined |
External sensor: you are able to attach a second sensor to terminals 6 and 7. You can then use an external sensor function to define the use of that sensor:
Warmup plc warrants this product, to be free from defects in the workmanship or materials, under normal use and service, for a period of three (3) years from the date of purchase by the consumer. If at any time during the warranty period, the product is determined to be defective, Warmup shall repair or replace it, at Warmup’s option.
If the product is defective, please either,
This warranty does not cover removal or reinstallation costs, and shall not apply if it is shown by Warmup that the defect or malfunction was caused by failure to follow the instruction manuals, incorrect installation or damage which occurred while the product was in the possession of a consumer. Warmup’s sole responsibility shall be to repair or replace the product within the terms stated above. WARMUP SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. THIS WARRANTY IS THE ONLY EXPRESS WARRANTY WARMUP MADE ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE THREE-YEAR DURATION OF THIS WARRANTY. This Warranty does not affect your statutory rights. PLEASE REGISTER YOUR WARMUP PRODUCT AT: www.warmup.co.uk
EXTENDED LIFETIME WARRANTY
reset Extended lifetime warranties are available for the Warmup 3iE Energy Monitoring thermostat. For further information, enquire at your local 3iE retailer, check online at www.3iE-warranty.co.uk or contact Warmup directly on 0845-345-2288
Download Manual
Warmup 3iE Programmable Thermostat Operational Guide
OTHER MANUALS
Warmup 3iE Programmable Thermostat Installation Guide
Warmup 3iE Programmable Thermostat Product Specifications
Warmup 3iE Energy-Monitoring Thermostat Installation Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…