The 3IE thermostat is designed to aid in the comfort of your home by providing timed regulation of your Warmup underfloor heating system. The thermostat is designed to receive temperature input signals from the following sensors:
The thermostat is not a safety device and should only be used with Warmup heating products. In order to avoid damaging your flooring the correct floor type should be selected during the thermostat programming process.
WARNING – Important safety note
This product uses mains voltage electricity and work should only be carried out by a qualified electrician. You should always isolate the power supply before attempting to install or repair the 3IE thermostat. The thermostat should not be put into operation unless you are certain that the entire heating installation complies with current general safety requirements for electrical installations. Electrical installation to be in accordance with latest IEE Wiring Regulations and appropriate Statutory Regulations.
The thermostat should be installed inside a single gang electrical wall box that is at least 30mm deep. For optimal performance the thermostat should be located in an area with good ventilation. It should not be beside a drafty window/ door, in direct sun-light or above another heat generating device (e.g. radiator or TV).
The thermostat is designed for operation between 0°C and 55°C with relative humidity less than 80%.
Location and installation of floor sensor
The optimum location of the floor sensor is described in each Warmup heater installation manual. Refer to that manual when selecting floor sensor location.
The floor sensor provided with the 3IE thermostat enables accurate temperature control of the floor heating system. When the thermostat is being used to control floor heating under a wooden floor or other delicate floor coverings such as carpet or vinyl the floor sensor MUST be installed.
The floor sensor must be at least 300mm from the wall and should be placed centre of two heating element runs.
When positioning the floor sensor avoid placing the sensor in areas where it may be exposed to sunlight or draughts. Avoid areas where there are hot water pipes that may affect the temperature reading.
As the warranty does not cover the floor, it is recommended that the floor sensor is installed into a non-conductive conduit. This will allow for easy replacement of sensor after the flooring has been laid.
Make sure the conduit has a gradual bend when it enters floor, this will ensure the sensor cable can be easily inserted or with-drawn. Seal the end with tape to prevent adhesive/screed from entering the conduit.
Route the conduit to the connection box. The end of the conduit should be easily accessible after the flooring has been fixed.
Warning: Do not attempt to cut conduit with sensor installed. This could lead to irreparable damage to your sensor.
Separate the front housing of thermostat from wall module:
Normal electrical installation (see numbering on diagram to right)
(should only be performed under the supervision of Warmup)
Fil Pilote installation: (only for use in France)
Second sensor installation: (2nd floor probe or exterior probe)
Master/Relay installation: (connecting 2 stats together)
Mounting thermostat into the wall box:
You can now power up the thermostat and begin the programming process. An easy to follow menu will guide you through the rest. If you want to turn on / off the thermostat and heating system then hold down the recessed button on the bottom of the stat for 3 seconds
When you have ensured that both the floor sensor and heating elements are working correctly you can complete the installation of floor covering and remove the protective cover on the front of the thermostat.
Your thermostat can give you two error indications:
Using the Gasket with the 3IE
The 3IE has a Ingress Protection rating of IP20 but this rating can be increased when used in conjunction with the Gasket supplied with the thermostat, in which case it is ingress Protection rated to IP32 but only when used in accordance with these instructions.
Fitting the Gasket
Remove backing from seal and attach to the back of the thermostat ensuring that there is a tight bond between the seal and the back of the thermostat.
Once fitted do not remove or attempt to refit the seal as this may affect the protection against ingress of water if the not fixed correctly.
UK
Warmup Plc 702 & 704 Tudor Estate
Abbey Road London NW10 7UW
T: 0845 345 2288
International: + 44 208 453 6868
F: 0845 345 2299
E-mail: uk@warmup.com
Website: www.warmup.co.uk
FRANCE
Warmup plc 16, Rue du Dr Leroy Suite 310 72000
France
T: 805 639 905
International: +33 805 639 905 F: +33 805 639 906
E-mail: france@warmup.com
Website: www.warmupfrance.fr
GERMANY
Warmup Heizsysteme Ottostraße 3
27793 Wildeshausen
T: +49 4431 948 700
F: +49 4431 948 7018
E-mail: de@warmup.com
Website: www.warmupdeutschland.de
PORTUGAL
Warmup Portugal
Rua Fundo de Vila, Loja R
3700-120 S. J. da Madeira
T: 800 812 080 (Portugal Only)
F: 800 812 063 (Portugal Only)
E-mail: portugal@warmup.com
Website: www.warmup.pt
SPAIN
Warmup sl Francisco de Rojas, 2 28010 Madrid
España
T: 800 099 988 (Spain Only)
F: 800 099 989 (Spain Only)
E-mail: españa@warmup.com
Website: www.warmup.es
Appliances with this symbol must not be disposed of with general waste. Seek guidance from your local government or the retailer where you purchased the product.
Download manual:
Warmup 3iE Programmable Thermostat Installation Guide
OTHER MANUAL:
Warmup 3iE Programmable Thermostat Operational Guide
Warmup 3iE Programmable Thermostat Product Specifications
Warmup 3iE Energy-Monitoring Thermostat Installation Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…