The 3iE thermostat is designed to aid in the comfort of your home by providing timed regulation of your Warmup floor heating system. The thermostat is designed to receive temperature input signals from the following sensors:
WARNING – Important safety note
This product uses mains voltage electricity and work should only be carried out by a qualified electrician. You should always isolate the power supply before attempting to install or repair the 3iE thermostat. Thethermostat should not be put into operation unless you are certain that the entire heating installation complies with current general safety requirements for electrical installations. Electrical installation to be in accordance with latest local electrical wiring code and appropriate Statutory Regulations.
FCC Notice
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
WET AREAS
Install the thermostat a minimum of 5ft away from showers, tubs and other sources of splashing water.
To install your thermostat on the wall, you’ll need a 4″x4″x2-1/8″ square back box with a single gang mud ring (also called plaster ring).
Opening the thermostat
Placing the back box
Connecting wires
IMPORTANT
Ensure that multi strand wires are fully inserted into twist-on wire connectors (wire nuts) and secured tightly. Any loose strands should be trimmed as they could cause a short-circuit.
Mounting the thermostat
Connect the power base wires to the power supply and load using twist-on wire connectors for copper wires (see diagram below), as supplied in the packaging box.
Second sensor installation (2nd-floor probe or exterior probe):
Master/Relay installation (connecting 2 stats together):
Powering up
You can now power up the thermostat and begin the programming process. An easy-to-follow menu will guide you through the programming. If you want to turn on / off the thermostat and heating system, hold down the recessed button on the bottom of the stat for 3 seconds.
It is important to test the GFCI for correct installation and function. Testing can only be carried out while the thermostat is calling for heat (see operating instructions for details).
When you have ensured that both the floor sensor, heating elements, and the GFCI are working correctly you can complete the installation of floor covering and remove the protective cover on the front of the thermostat.
Errors messages | |
heater error | This will occur if the heating system is not correctly connected to the thermostat |
overload | This will occur if more than 15 Amps have been connected to the thermostat |
er1 | This will occur if no floor sensor is detected |
er2 | This will occur if the floor sensor has a short circuit. |
ground fault message | This will occur if a ground fault is detected |
Warmup Inc warrants this product, to be free from defects in the workmanship or materials, under normal use and service, for a period of three (3) years from the date of purchase by the consumer. If at any time during the warranty period, the product is determined to be defective, Warmup shall repair or replace it, at Warmup’s option. If the product is defective, please either,
This warranty does not cover removal or reinstallation costs, and shall not apply if it is shown by Warmup that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer. Warmup’s sole responsibility shall be to repair or replace the product within the terms stated above.
WARMUP SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. THIS WARRANTY IS THE ONLY EXPRESS WARRANTY WARMUP MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE THREE-YEAR DURATION OF THIS WARRANTY.
This warranty does not affect your statutory rights.
PLEASE REGISTER YOUR WARMUP PRODUCT AT: www.warmup.com (USA) or www.warmup.ca (CANADA)
OPERATING YOUR THERMOSTAT
You can view or download the programming manual from our website at:
For more information about the 3iE, please also check
Warmup Inc
52 Federal Road Unit 1F Danbury, CT 06810
USA
T: 888-927-6333
F: 888-927-4721
us@warmup.com
www.warmup.com
4 Robert Speck Parkway, Suite 1500, Mississauga, ON L4Z 1S1
Canada
T: 888-5-WARMUP (92-7687)
F: +1-905-366-7324
Email: ca@warmup.com
www.warmup.ca
Download Manual
Warmup 3iE Energy-Monitoring Thermostat Installation Manual
OTHER MANUALS
Warmup 3iE Programmable Thermostat Operational Guide
Warmup 3iE Programmable Thermostat Installation Guide
Warmup 3iE Programmable Thermostat Product Specifications
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…