WarmlyYours

WarmlyYours ‎UDG-4999 nHance Programmable Thermostat Quick Start Guide

WarmlyYours ‎UDG-4999 nHance Programmable Thermostat

Introduction

This thermostat can switch on your heating system at predetermined times on different days of the week. For each day of the week, you can set individual temperatures for 4 periods, called events. The thermostat comes with a default schedule suitable for most installations. Unless you change the settings, the thermostat will operate in compliance with the default schedule. Lowering the temperature when the home is unoccupied will reduce your energy costs without reducing comfort. Furthermore, the thermostat features an adaptive function that automatically changes heating period start times so as to ensure that the required temperature is reached at the required time.The full manual can be downloaded at: WWW.OJ-MICROLINE.COM/INTUITE

FIRST TIME SETTINGS

Time and day:

  • The first time you turn on the thermostat, time and day must be set.
  • The time flashes. Set the current time using the Up or Down button.
  • Then press the OK button to confirm the time. The day of the week will then flash. Select the current day using the Up or Down button.
  • Press the OK button.

Select Mode:

  • The thermostat features 3 different modes of temperature control:
  • Auto: Controlled automatically via the 4-event schedule.
  • Override: Change the temperature for a single event.
  • Manual: Set a temperature manually. 4-event program is cancelled.
  • Press OK to access Mode and select the required mode using the
  • Up or Down button. Press the OK button.

Select Schedule:

  • The weekly 4-event schedule:
  • 5:2: Mon-Fri with 4 events/Sat-Sun with 2 events.
  • 6:1: Mon-Sat with 4 events/Sun with 2 events.
    7:0: Mon-Sun with 4 individual events.
  • Press the Up or Down button until the Schedule option flashes.
  • Press OK and then press the Up or Down button until the required program (5:2, 6:1 or 7:0) flashes. Confirm with OK.

How to program the thermostat
The thermostat is pre-programmed with a 4-event program, see Factory Settings below. The program can be adapted individually for the following 4-events:

  • when I wake up in the morning
  • when I am away at work
  • when I come home
  • and at night
  • Press the Up or Down button until the Program option flashes.
  • Press the OK button.
  • Press the Up or Down button until the day(s) that you wish to program flash in the lower part of the display, e.g. Mon Tue Wed Thu Fri. Press OK.
  • The symbol for the first event will now flash. The hour will flash, allowing you to set the hour at which you want the morning period to begin. Press the Up or Down button until the required hour is displayed.
  • Press the OK button. The minutes will flash.
  • Press the Up or Down button until the required minutes are displayed, press OK.
  • The temperature setting will now flash in the upper part of the display. Press the Up or Down button to set the required temperature. Press the OK button.
  • The symbol for the next event (e.g. at work) will now flash, allowing you to set the time and temperature for this period of the day by repeating steps 3-5.
  • Once the four events have been set for all days, the display will return to the Program menu. Finally, select Exit to exit the Program for a 5:2 schedule.

Ground Fault Circuit Interrupter (GFCI)
The thermostat has a built-in GFCI that ensures personal safety in case of ground faults. It is important that the GFCI is checked monthly. See full manual on www.oj-microline.com/intuite

Settings

The Settings option allows the following to be set:

  • Time: Set the hour and minutes.
  • Day: Set the actual day.
  • Child lock: Activate the child lock. To unlock, press OK to activate the menu, then hold the Up and Down buttons simultaneously for 3 seconds. °C / °F: Choose between Celsius and Fahrenheit.
  • Application: Select the type of control used: Room/Floor/Regulator/Room limit*.
  • Offset temp: Adjust the measured temperature.
  • Readout: Readout of energy consumption in per cent, software version and application.
  • Adaptive: Ensures the required temperature is reached at the programmed time.
  • Display: Select what is shown on the default display.
  • Factory reset: Restore factory settings.
Exit Menu
  • The various menus and sub-menus contain an Exit option.
  • Press the Up or Down button until Exit flashes.
  • press the OK button. You may have to repeat steps 1 and 2 to return to the final Exit option.

Factory Settings for Automatic 5:2 Program

Days 1-5 (Monday – Friday)
Event Time Temperature
Morning 6:00 a.m. – 8:00 a.m. 77°F / 25°C
Out 8:00 a.m. – 4:00 p.m. 68°F / 20°C
Home 4:00 p.m. – 10:00 p.m. 77°F / 25°C
night 10:00 p.m. – 6:00 a.m. 68°F / 20°C
Days 6-7 (Saturday – Sunday)
Event Time Temperature
Day 8:00 a.m. – 11:00 p.m. 77°F / 25°C
night 11:00 p.m. – 08:00 a.m. 68°F / 20°C

Reference

Download Manual:

WarmlyYours ‎UDG-4999 nHance Programmable Thermostat Quick Start Guide

WarmlyYours ‎UDG-4999 nHance Programmable Thermostat Quick Start Guide

wpx_thermostats

Recent Posts

Bad Ragaz Casino No Deposit Bonus Codes For Free Spins 2026

Bad Ragaz Casino No Deposit Bonus Codes For Free Spins 2026 Details pertaining to the…

3 weeks ago

Online Slot Games For Money

Online Slot Games For Money Playing online casinos UK on a mobile device Spin the…

3 weeks ago

Prime Fortune Casino No Deposit Bonus Codes For Free Spins 2026

Prime Fortune Casino No Deposit Bonus Codes For Free Spins 2026 Fantasy sports became a…

3 weeks ago

Online Casino Real Money Uk No Deposit

Online Casino Real Money Uk No Deposit Get ready to play the most realistic card…

3 weeks ago

Sin88 Casino No Deposit Bonus Codes For Free Spins 2026

Sin88 Casino No Deposit Bonus Codes For Free Spins 2026 This can be part of…

3 weeks ago

How To Always Win Blackjack

How To Always Win Blackjack Casino offer terms and conditions in UK Here is how…

3 weeks ago