Installation Tips

Wall Location

The thermostat should be installed approximately 4 to 5 feet above the floor. Select an area with average temperature and good air circulation

Subbase Installation

  • Horizontal Mount
  • Vertical Mount

Installation Tip:

Electrical Hazard
Failure to disconnect the power before beginning to install this product can cause electrical shock or equipment damage.

Mercury Notice
All of our products are mercury free. However, if the product you are replacing contains mercury, dispose of it properly. Your local waste management authority can give you instructions on recycling and proper disposal.

Thermostat Application Guide

Description
Gas or Oil Heat Yes
Electric Furnace Yes
Heat Pump (No Aux. or Emergency Heat) Yes
Heat Pump (With Aux. or Emergency Heat) Yes
Multi-Stage Systems Yes
Heat Only Systems Yes
Cool Only Systems Yes
Millivolt Yes

Power Type

  • Battery Power
  • Hardwire (Common Wire)
  • Hardwire (Common Wire) with
  • Battery Backup

Mount Thermostat

Align the 4 tabs on the subbase with corresponding slots on the back of the thermostat, then push gently until the thermostat snaps in place.

Battery Installation

Battery installation is optional if thermostat is hardwired (R and C terminal connected to 24V power).

Important:
High quality alkaline batteries are recommended. Rechargeable batteries or low quality batteries do not guarantee a 1-year life span.

About The Private Label Badge

Getting to know your thermostat

  • LCD Display
  • Glow in the dark light button
  • Fan Button
  • System Button
  • Temperature Setpoint Buttons
  • User Buttons
  • Private Label Badge

  • Indicates the current room temperature
  • Time and day of the week
  • Low Battery Indicator: Replace batteries when this indicator is shown
  • Menu Options: Shows different options.
  • Program Time Periods: This thermostat has 4 programmable time periods per day.
  • System Operation Indicators: The COOL ON , HEAT ON or icon will display when the COOL, HEAT, or (fan) is on. The compressor delay feature is active if these are flashing.
  • The hold is displayed when the thermostat program is permanently overridden
  • Setpoint: Displays the selected setpoint temperature
  • System: Indicates current mode of operation
  • Stages: +1 will appear in the display when the second stage of heat or cool is on. +2 will appear for third stage of heat
  • Globe: Globe is displayed if an energy-efficient temperature has been selected

Wiring

  • If you are replacing a thermostat, make note of the terminal connections on the thermostat that is being replaced. In some cases the wiring connections will not be color coded.
  • For example, the green wire may not be connected to the G terminal.
  • Loosen the terminal block screws. Insert wires then retighten terminal block screws.
  • Place nonflammable insulation into wall opening to prevent drafts

Wiring Diagrams

C Terminal
The C (common wire) terminal does not have to be connected when the thermostat is powered by batteries

Wire Specifications
Use shielded or non-shielded 18-22 gauge thermostat wire

  • Power supply
  • Factory-installed jumper. Remove only when installing on 2 transformer systems.
  • System: Indicates current mode of operation
  • Optional 24 VAC common connection when the thermostat is used in battery power mode.

Typical 2H/2C System: 1 Transformer

Typical Cool-Only System With Fan / Typical Heat-Only System With Fan

Typical 2H/2C System: 2 Transformer/ Typical 2H/1C Heat Pump System

Features

Temporary and Permanent Hold Feature

  • When cool or heat is turned on, the thermostat will display HOLD and RUN SCHED on the left of your screen when you press the button.
  • Temporary Hold: At this time if you do nothing, the temperature will remain at this setpoint temporarily for 4 hours.
  • Permanent Hold: If you press the HOLD key on the left of your screen, you will see HOLD appear below the setpoint temperature in the display. The thermostat will now permanently stay at this setpoint and can be adjusted using the keys.
  • To Return to Running Schedule: Press the RUN SCHED button on the left of your screen to exit either temporary or permanent hold.

Filter Change Reminder
If your installing contractor has configured the thermostat to remind you when the air filter needs to be changed, you will see FILT in the display when your air filter needs to be changed

Resetting the filter change reminder: When FILT reminder is displayed, you should change your air filter and reset the reminder by holding down the second button from the top left side of the thermostat for 3 seconds

Technician Setup Menu

  • Press the MENU button.
  • Press and hold the TECH SET button for 3 seconds. This 3 second delay is designed so that homeowners do not accidentally access the installer settings.
  • Configure the installer options as desired using the table below.
  • Use the keys to change settings and the NEXT or PREV key to move from one step to another.
  • Note: Only press the DONE key when you want to exit the Technician Setup options.
  • Press the DONE key to exit

Swing Setting Tip
Temperature swing, sometimes called differential or cycle rate, can be customized for this individual application. For most applications choose a swing setting that is as long as possible without making the occupants uncomfortable.

Programming

Set Time

  • With system switch set to OFF, press the MENU button
  • Press SET TIME
  • Day of the week will be flashing. Use the key to select the current day of the week.
  • Press NEXT STEP
  • The current hour is flashing. Use the key to select the current hour. When using 12-hour time, make sure the correct a.m. or p.m. choice is selected.
  • Press NEXT STEP
  • Minutes are now flashing. Use the key to select current minutes.
  • Press DONE when completed

Programming

All of our programmable thermostats are shipped with an energy saving pre-program. You can customize this default program by following the steps on the next page. There are four time periods for each program (WAKE, LEAVE, RETURN, SLEEP).

Set Program Schedule 5+1+1 or 7 Day

  • Select HEAT or COOL with the system switch. Note: You have to program heat and cool each seperately.
  • pess the MENU button (If menu does not appear first press RUN SCHED)
  • Press SET SCHED. Note: Monday-Friday or (Monday if in 7 Day) is displayed and the WAKE icon is shown. You are now programming the waketime period for that day.
  • Time is flashing. Use the key to make your time selection for that day’s WAKE time period.
    Note: If you want the fan to run continuously during this time period, select ON with the FAN key
  • Press NEXT STEP the setpoint temperature is flashing. Use the key to make your setpoint selection for that day’s WAKE time period.
  • press NEXT STEP
  • Repeat steps 4 thru 7 for that day’s LEAVE time period, RETURN time period, and SLEEP time period.

You can use the table below to plan your customized program schedule

Specifications

  • The display range of temperature … 41˚F to 95˚F (5˚C to 35˚C)
  • The control range of temperature… 44˚F to 90˚F (7˚C to 32˚C)
  • Load Rating……………………………………….. 1 amp per terminal, 1.5 amp maximum all terminals combined
  • Swing (cycle rate or differential) …… The heating is adjustable from 0.2˚ to 2.0˚
  • Cooling is adjustable from 0.2˚ to 2.0˚
  • Power source …………………………………….18 to 30 VAC, NEC Class II, 50/60 Hz for hardwire
  • Battery power from 2 AA Alkaline batteries
  • Operating ambient …………………………. 32˚F to +105˚F (0˚C to +41˚C)
  • Operating humidity ………………………… 90% non-condensing maximum
  • Dimensions of thermostat …………….. 4.7” W x 4.3” H x 0.9” D

Reference

Download Manual:

Vive Comfort TP-S-755 Non-Programmable Thermostat Installation Manual

OTHER MANUALS

Vive Comfort TP-S-755 Non-Programmable Thermostat Operational Manual

Vive Comfort TP-S-755 Non-Programmable Thermostat Installation Manual

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

1 year ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

1 year ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

1 year ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

1 year ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

1 year ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

1 year ago