Electronic Wi-Fi thermostat for local control and advanced remote temperature management via View App, heating and air conditioning in ON/OFF and PID mode, class I temperature control device (contribution 1%) in ON/OFF mode, class IV (contribution 2%) in PID mode, configuration via View App on standard Bluetooth technology, 1 digital input, 1 relay output 5(2) A 240 V~, power supply 100-240 V~ 50/60 Hz, white LED backlighting, surface mounting, white.
For details please refer to the manual entitled “Programming thermostats 02912-02913” available for download from www.vimar.com
OPERATION WITHOUT CONFIGURATION VIA APP
If the configuration is not done via the View App, the thermostat is designed to accommodate operation in manual mode.
RESETTING THE THERMOSTAT.
The reset restores the factory settings. Within the first 5 minutes within which it is powered, press button B for 30 s.
Using the View App, making use of the WiFi/Internet connection the following can be set:
In the event of a power outage, once the power is restored, the thermostat restarts with the operating mode prior to the outage. If the mode set was “Automatic” the thermostat will restart in “Manual” mode and the first time it reconnects to the Cloud, it will synchronize the time/date again and then switch to “Automatic” mode.
The thermostat display shows the current temperature; when you use “ ” and “ point being set during the action is displayed.
RED Directive. RoHS directive. ERP directive.
Standards EN 60730-2-7, EN IEC 60730-2-9, EN 300 328, EN 301 489-17, EN 62311, EN IEC 63000.
Temperature control device regulation (EU) no. 811/2013.
Vimar SpA declares that the radio equipment complies with Directive 2014/53/EU. The full text of the EU declaration of conformity is on the product sheet available on the following website: www.vimar.com
REACH (EU) Regulation no. 1907/2006 – Art.33. The product may contain traces of lead.
The crossed bin symbol on the appliance or on its packaging indicates that the product at the end of its life must be collected separately from other waste. The user must therefore hand the equipment at the end of its life cycle over to the appropriate municipal centers for the differentiated collection of electrical and electronic waste. As an alternative to independent management, you can deliver the equipment you want to dispose of free of charge to the distributor when purchasing a new appliance of an equivalent type. You can also deliver electronic products to be disposed of that are smaller than 25 cm for free, with no obligation to purchase, to electronics distributors with a sales area of at least 400 m2. Proper sorted waste collection for subsequent recycling, processing and environmentally conscious disposal of the old equipment helps to prevent any possible negative impact on the environment and human health while promoting the practice of reusing and/or recycling materials used in manufacture. The Apple, iPhone and iPad logos are trademarks of Apple Inc., registered in the United States and in other Countries and Regions. App Store is a service trademark of Apple Inc. Google is a trademark of Google LLC. Amazon, Alexa and all related logos are trademarks of Amazon.com, Inc. or its affiliates.
• Short press = adjustment of set point from 4°C to 40°C in steps of 0.5°C• Long press (5 s) = if on standby the thermostat is switched off; if switched OFF the thermostat is switched on | |
A | Display• bt = thermostat in Bluetooth configuration • off = thermostat off; on = thermostat on • °C = degrees Celsius; °F = degrees Fahrenheit • animation from the bottom up = Heating • animation from the top down = Air conditioning • Rst = thermostat reset • PIN = PIN entry prompt • Alr, Con, Cld, etc. = alarms |
B | • Short press = degrees Celsius/Fahrenheit selection• Long press (5 s) = the thermostat enters the configuration phase (bt) • Prolonged press (30 s) within the first 5 min of powering = thermostat reset (Rst) |
Using a screwdriver, detach the thermostat from the bracket as shown in the figure.
Make the connections and fix the bracket to the wall.
Caution: Tighten the wall bracket screws, applying sufficient torque without exaggerating, in order to avoid warping it.
Fix the thermostat to the bracket using the dedicated attachments shown in the figure.
Download Manual:
VIMAR 02912 Smart Clima Wi-Fi Thermostat Instruction Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…