Verdant

Verdant VX-TL-KT-W Wireless Energy Management THERMOSTAT Product Specifications Guide

Verdant VX-TL-KT-W Wireless Energy THERMOSTAT

INTRODUCTION

  • Easy-to-use Thermostat
  • Unparalleled Energy Savings
  • Aux output for occupancy-based control of external devices (i.e. lights, receptacles, outside air dampers)
  • Facilitates compliance with energy effi ciency codes such as Title 24, and IECC 2015/2018.
  • Online management capabilities¹

The Verdant VX-TL-KT thermostat delivers unprecedented energy savings without compromising guest comfort.
New energy-efficient building codes have raised the energy performance standards required of commercial buildings. California’s Title 24 (Part 6) building code as well as other state building codes founded upon IECC 2015 or 2018 energy efficiency codes have now mandated occupancy-based control of heating and air-conditioning, lighting, outside air dampers, and/or receptacles. The Verdant VX-TL-KT thermostat reduces HVAC runtime by dynamically setting back temperature in empty rooms, without disturbing the comfort of occupants. The thermostat can also shut off power to a lighting circuit by using an external relay that receives the thermostat’s occupied/ unoccupied signal.
The occupied/unoccupied signal can be configured to be Normally Open (NO) or Normally Closed (NC). This provides unsurpassed fl exibility when connecting to other systems like outside air dampers or exhaust fans.
The Verdant Thermostat and Verdant HVAC Controller communicate wirelessly for a simple and effortless installation. The Verdant HVAC The controller connects to the HVAC unit using standard thermostat terminals (7 wires). In the case of a mini split or VRF unit, please contact Verdant Sales for the applicable part number.
The Verdant thermostat is powered at 24VAC in order to provide the required voltage for the occupancy output signal.
Verdant’s combined solution offers building owners a cost-effective energy management system that can be deployed with minimal accessories, and little to no extra labor, making it simple to install.

  1. Requires a network access license for each thermostat (Part Number: XMF) and one “Online Connection Kit” (Part Number: OL-KT). Additional fees apply.
  2. In jurisdictions where building codes mandate any of the undermentioned measures, additional software licenses (Part Number: XMF) and one (1) Online Connection Kit are required. Additional fees apply.

The VX-TL-KT thermostat facilitates building-code compliance by addressing the following requirements:2†
IECC 2015

  1. C405.2.4.3 Specifi c application controls for sleeping units.

IECC 2018

  1. C.403.7.6 Automatic Control of HVAC system serving guestrooms integrally.
  2. C405.2.4.2 Specific application controls for sleeping units Title 24 Part 6
  3. Section 130.1(c)8 Shut-off controls for Hotel/Motel guestrooms.
  4. Section 120.2(e) Shut-off and Reset Controls for Space conditioning Systems
  5. Section 130.5(d) Circuit Controls for 120V Receptacles and Controlled Receptacles.

Technical Specifications

Case Dimensions (Imperial) 4.02 x 5.51” x 0.93” 3.88” x 2.13” x 0.75” 2.5” x 3.5” x 0.73”
Case Dimensions (Metric) 102mm x 140mm x 23.5mm 98mm x 54mm x 19mm 63.5mm x 88.9mm x 18.5mm
Screen Dimensions (Imperial) 3.63” x 2.13” N/A N/A
Screen Dimensions (Metric) 92mm x 54mm N/A N/A
Operating Voltage 24VAC 24VAC 24VAC
Control Outputs Occupuancy Out (Aux) Fan High (GH)
Fan Low (GL)
Compressor (Y)
Heat Pump (OB)
Heat (W)
Occupancy Sensor Beam Width ±47° (94°) N/A ±47° (94°)
Wireless Frequency 902-928MHz 902-928MHz N/A
Temperature Accuracy ±1°F N/A N/A
FCC ID XEYWX XEYV8ACCC N/A
IC 8410A-WX 8410A-V8ACCC N/A

Typical HVAC Applications

  • PTAC with Electric Heat
  • FCU 2-Pipe, 2 Fan, with Electric Heat
  • Heat Pump, 2 Fan, with Electric Heat
  • VRF Systems (Part # VX-RSW-W )
  • PTHP with Electric Heat
  • FCU 4-Pipe, 3 Fan
  • WSHP, 2 Fan, with Electric Heat
  • Mini Splits (Part # VX-RSW-W )

FCC

THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS:

  1. THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND
  2. THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.

PURSUANT TO PART 15.21 OF THE FCC RULES, ANY CHANGES OR MODIFICATIONS TO THIS EQUIPMENT NOT EXPRESSLY APPROVED BY VERDANT ENVIRONMENTAL TECHNOLOGIES, INC. MAY VOID VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT.

US PATENTS: 8,369,994; 8,141,791; 7,918,406; 7,841,542; 7,838,803; RE40,437; 7,232,075; 7,185,825; 7,156,318; 7,152,806; 7,145,110; 7,058,477; 7,050,026; 7,028,912; 6,902,117; 6,789,739; 6,786,421; 6,619,555; 6,581,846; 6,578,770; CANADIAN PATENTS: CA2615065; CA2633113; CA2633121; CA2633200; OTHER PATENTS PENDING.
Verdant Environmental Technologies, Inc. reserves the right to make changes, without notice, in design or components as progress in engineering and manufacturing methods may warrant. Product appearance may vary.
© Verdant Environmental Technologies, Inc. 2021

Requires a network access license for each thermostat (Part Number: XMF) and one “Online Connection Kit” (Part Number: OL-KT). Additional fees apply.
020421 Emerson is a trademark of Emerson Electric Co. ©2020 Emerson Climate Technologies, Inc. All rights reserved

REFERENCE

Download Manual

Verdant VX-TL-KT-W Wireless Energy Management THERMOSTAT Product Specifications Guide

Verdant VX-TL-KT-W Wireless Energy Management THERMOSTAT Product Specifications Guide

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

1 year ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

1 year ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

1 year ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

1 year ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

1 year ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

1 year ago