Home Screen
Dropdown Dashboard
The Dropdown Dashboard displays temperature, and other readings. It will also show the high and low readings of the day.
Care and Use of Your Thermostat
Pencils, pens and other sharp objects should never be used on your thermostat; these may damage your touchscreen. Only use your fingertip to press the touchscreen buttons.
DO NOT USE ABRASIVE CLEANERS OR CLEANERS THAT CONTAIN SOLVENTS. DO NOT SPRAY ANYTHING DIRECTLY ONTO THE THERMOSTAT.
Selecting Your Desired Temperature and Mode
Using the Fan Button
Press the FAN Icon
FAN ON fan runs constantly even in OFF Mode.
FAN AUTO fan only runs with a heating or cooling demand.
Using the Override Button
NOTE: Override may only be used when the thermostat is set to Program RUN or Holiday ON modes.
Unoccupied Operation – During programmed, unoccupied periods, pressing the OVERRIDE button will force the thermostat into Occupied 1 settings. When the OVERRIDE button is pressed, a timer screen will appear and allow the user to choose from 30 minutes to up to 4 hours of override time.
To turn off the override timer, press the OVERRIDE button and when the timer screen appears, press CANCEL OVERRIDE.
Occupied Operation – During programmed, occupied periods, pressing the OVERRIDE button will force the thermostat into an unoccupied period for the rest of the day. During this forced unoccupied period the OVERRIDE button will operate as described above.
Holiday Operation – During Holiday Mode, pressing the OVERRIDE button will force the thermostat into Occupied 1 settings. When the OVERRIDE button
is pressed, a timer screen will appear and allow the user to choose from 30 minutes to up to 4 hours of override time. To turn off the override timer, press the OVERRIDE button and when the timer screen appears, press CANCEL OVERRIDE.
NOTE: When the thermostat is connected to a Skyport account, the Time & Date are automatically synchronized to the Skyport Cloud, including automatic Daylight Savings adjustments. Your time zone is selected in the Skyport web application.
Setting the Time
Setting the Date
Connect to Wi-Fi (from initial start up)
When power is connected to the thermostat and it has not been configured to connect to a Wi-Fi Access point, the following message appears:
Connect to Wi-Fi (from menus)
Although there is more than one way to create a Skyport account, the steps below illustrate creation from a browser.
If the thermostat is connected to the local Wi-Fi Access Point, but not yet joined to a Skyport account, you may join the thermostat to an account by doing the following:
Skyport Account
This thermostat features up to 3 Occupied time periods
per 24 hour day.
View My Schedule
Press a day of the week to view its settings. This may be repeated for each day.
Press and select a Time Period (Occupied 1, Occupied 2, or Occupied 3) to edit.
TIP:
Occupied 2 will override Occupied 1, and Occupied 3 will override Occupied 1 & 2.
Edit My Schedule
Adjust Mode, Start Time, Stop Time, and Heat and Cool Se tpoints to desired settings. The Time Period May also be Enabled or Disabled. Un-check the enabled box for Time Periods you don’t want to use. Press DONE when finished.
When you are finished editing the time periods press
Review your program.
Press SAVE to keep your program. Press EDIT to make further changes.
The fan may be set to run continuously during Heat, Cool, Auto, and Occupied modes. A Preoccupancy Fan Purge schedule may also be set.
Press to turn fan On to run continuously or Auto for fan to run only with heating or cooling.
The Screensaver allows you to create custom slideshows.
Press this button to preview your screensaver operation before returning to the Home Screen.
After the preview, press anywhere on the screen to return to the sub menu.
The alerts let you know when your system needs service.
The display brightness options may be adjusted in this menu.
When calibration is complete, the thermostat will automatically restart and return to the Home Screen.
You may set the type of background that appears on the thermostat Home Screen.
The Holiday Schedule allows the Color Touch Screen to follow a fully customizable preset, weekly, monthly, and yearly holiday program. The thermostat will stay in Unoccupied settings while Holiday is active.
Start by selecting a Holiday.
You may continue to select more holidays or you can press the Repeat button for recurring holidays.
Pressing a selected holiday will deselect that holiday.
Using the Repeat Button
Choose to repeat the holiday every week, month or year. Or, press CANCEL to go back.
If you choose to repeat the holiday every week, you will be prompted to confirm the day of the week to be repeated.
Using the Info Button
Press the Info button to view how non-holidays, holidays, and exceptions to repeating holidays will appear on the Holiday calendar.
Deselecting Holidays
You may deselect a holiday simply by pressing on it.
Press BACK to save your changes and return to the Holiday menu.
If you choose to deselect a holiday that is part of a Custom Repeating Program, the screen below will appear.
Marking Non-Holidays
You will now be prompted to mark this day only as a non-holiday or edit All repeating holidays that affect this day.
Press SAVE to mark only this day as a non-holiday.
If you choose to edit repeating holidays
that affect this day, press NEXT and the next screen will appear.
Editing Repeating Holidays
If, for example, you choose to repeat the holiday every month, the following screen will appear:
You may now choose to repeat the holiday:
Edit Holidays
You may now delete all repeating custom holidays in this group by pressing the ON box to uncheck your selection. Press SAVE to return to Holiday editing screens.
Preset Holidays
You may choose from several standard preset holidays to observe. When the preset holidays are set to ON, they will be observed every year on that date.
Overriding Holiday Mode
You may override Holiday Mode by pressing the OVERRIDE button and choosing the amount of override time desired.
Turning Off Holiday Mode From The Homescreen
You may turn off Holiday Mode by pressing the MODE button and then pressing the Holiday STOP button.
Security settings may be
set to limit or prevent changes to your thermostat.
This button contains valuable service and system runtime information.
Thermostat heating and cooling options are found in this menu
At 6 cycles per hour, the HVAC unit will only be allowed to energize once every 10 minutes. The Cycles Per Hour limit may be overridden and reset by pressing the WARMER or COOLER buttons.
Automated Demand Response
ColorTouch thermostats support the handling of specific signals from the utility provider. The utility-generated signals carry pricing information and/or setback actions that alter the comfort settings of the thermostat in order to reduce energy usage on demand. This is known as Automated Demand Response or ADR for short. You must register to participate in a utility-sponsored program, if offered by your local utility, to take advantage of this feature.
SKYPORT CLOUD SERVICES
From the web application, the user will select Thermostat Settings from the left column. Then the Demand Response button is selected.
The Demand Response configuration page, shown below, is where the thermostat is configured to respond to the energy provider’s signals. It also sets operational parameters for the thermostat.
The left column of the ADR configuration page allows or prevents access by the utility. Here communication with the utility and your thermostat may be turned On or Off.
The selected utility will provide a Program ID.
The Account ID would normally be the occupants utility account number.
The right column of the ADR configuration page is where the occupant adjusts the operational parameters for ADR. The utility may send up to 3 types of ADR signals to Skyport. These are:
1) Pricing for the cost of energy, 2) An Offset to the occupants’ comfort setpoints, and 3) a signal to enforce discrete or Static setpoints.
The Maximum Cooling Setpoint and Minimum Heating Setpoints for ADR events are adjusted here.
The Static Settings are applied when the utility sends a signal to allow the occupant to enforce their own discrete temperature settings during an ADR event.
The Offset Settings allow the utility to modify the Cool or Heat setpoints by the value set here during an ADR event.
A Price Trigger setting allows the occupant to set the maximum cost of energy threshold. When this threshold is exceeded
the Price dependent action is enforced. This Price Trigger and Dependent action is enforced independent of an ADR event, as long as the utility sends ‘real-time’ pricing.
Selecting the Overview tab of the ADR page will cause a summary of ADR events to be displayed.
Automated Demand Response
Utility and Program setup must be done at the Skyport Cloud Services account. From the thermostat Home Screen, press the ‘Menu’ button, then select ‘Settings”.
By selecting ADR – On, the user can participate in ADR events triggered by their utility, or price dependent events.
In the above example; if the price threshold is exceeded, the thermostat will invoke the ‘Offset Setpoints’ configured for an ADR event until the event is over.
Please note that the Threshold price may only be set in the Skyport Cloud Services account.
Selecting ‘Skip Event’ will take no action when the set price threshold is exceeded.
When an ADR event is pending, and hasn’t started yet, there will be a yellow leaf on the top bar. This will be accompanied by associated text as shown below.
If a Warmer or Cooler button is pressed during an active ADR event, then the user is presented with this opt-out screen.
If a pricing triggered ADR event is enabled, there will be a green leaf on the top bar along with the actual cost of energy. This will be accompanied by associated text as shown below
The Deadband is the number of degr ees or minutes that the thermostat waits before it initiates the stages of heating or cooling.
1st Stage Deadband Specifies the minimum temperature difference between the room temperature and the desired setpoint before the first stage of heating or cooling is allowed
to turn on. For example, if the heat setpoint is 68˚ and the 1st Stage deadband is set to 2 degrees, the room temperature
will need to drop to 66 degrees before the heat turns on.
Dealer Information
A Dealer may enter their company contact information for the customer to use when they need service. This will appear when the “Who To Call For Service” button is pressed in the Information Menu.
Use the keyboard to enter your information.
Upgrade Firmware
Press to upgrade the thermostat firmware. The SD Card must be in the thermostat SD Card reader and contain the valid firmware. If an error message appears, confirm with ColorTouch Assistant that firmware is up
to date or simply try reinserting the SD card.
If you are connected to Skyport Wi-Fi and you receive an Alert that new firmware is available, simply press the Upgrade Firmware button to upgrade wirelessly.
Note: Occasionally an update that requires a large amount of data is not possible to do wirelessly. In this case an update using an SD card will be required.
Wi-Fi Status
It is here that you will find helpful information regarding the connectivity status of your thermostat, including the thermostat’s ID.
Wi-Fi Setup
Choose your network from the list and enter the network password.
If your network does not appear in the list, hit the refresh button.
Local API Option
Turning on the local API allows 3rd party software to interface with your thermostat, such as a home automation system.
This is the default with the local API OFF.
Upon pressing BACK, the screen will look like this.
Basic Auth Password
Select Basic Auth Password and enter the appropriate information on the screen below and press DONE to save.
The last step is to turn the Local API on as shown below.
The Emergency Heat function
is only available if your thermostat is set to control a Heat Pump.
To initiate the Emergency Heat feature, Press the Emergency Heat button. During Emergency Heat operation the thermostat will turn on the fan and auxiliary stages of heat when there is a demand for heat. The 1st stage of heating and all stages of cooling will be unavailable. To exit Emergency Heat, press the Emergency Heat button.
ColorTouch Assistant may be downloaded at no charge at: www.venstar.com/thermostats/colortouch/assistant
Every time the user runs the ColorTouch Assistant software,
it automatically connects to Venstar ColorTouch website in the background and updates the software and firmware
(the operating system for ColorTouch) at no cost.
The ColorTouch Assistant allows you to use your computer to:
Uploading Photos and Settings to your thermostat
When you are finished adding and editing photos and settings, click on Save to SD. When prompted, remove the SD card from the SD card reader on your computer.
At the thermostat:
Insert the SD card into the SD Card Slot
Your thermostat will automatically save your new photos and settings in it’s internal memory. When finished, you may remove the SD card. It is not needed for normal thermostat operation.
Remove and Replace the old thermostat
To install the thermostat properly, please follow these step-by-step instructions. If you are unsure about any of these steps, call a qualified technician for assistance.
If the terminal designations on your old thermostat do not match those on the new thermostat, refer to the chart below or the wiring diagrams that follow.
Wire from the old thermostat terminal marked | Function | Install on the new thermostat connector marked |
G or F | Fan | G |
Y1, Y | Cooling | Y1 |
W1, W | Heating | W1/0/B |
Rh, R, M, Vr, A | Power | R |
C | Common | C |
O/B | Rev. Valve | W1/O/B* |
W2 | 2nd Stage Heat | W2 |
Y2 | 2nd Stage Cooling | Y2 |
W3 | 3rd Stage Heat | W3 |
OUT – | Outdoor Sensor | SENSOR |
OUT + | Outdoor Sensor | SENSOR |
Before you go any further, determine what your existing wiring and equipment situation is.
Making 4 Wires Work When 5 Wires Are Required
If you would like to install the Venstar thermostat using only 4 wires when 5 are required, follow the directions below. You will need a screwdriver along with a 3″ long piece of thermostat wire to use as a jumper:
Making 5 Wires Work When 6 Wires Are Required
If you have a system that requires 6 wires, and you would like to install the Venstar thermostat using only 5 wires, follow the directions below. You will need a screwdriver along with a 3″ long piece of thermostat wire to use as a jumper:
NOTE:
The backplate does not fully cover a full-size vertical junction box. The ACC-WPLWH Venstar Wallplate or a
single-gang, horizontally mounted junction box would be needed for that type of installation
To remove the thermostat backplate:
Using the Finger Pull Areas, pull the front housing away from the backplate.
IMPORTANT: This thermostat requires both R (24 VAC Return) and C (24 VAC Common) be connected to the backplate terminals.
Dip switches are located on the back of the thermostat
This dip switch configures the thermostat to control a conventional gas/electric system or a heat pump. If your system is anything other than a heat pump, leave this switch set for GAS/EL.*
*For some commercial heat pumps, this switch may need to be set for GAS/EL. Consult the commercial heat pump literature.
When the GAS/EL or HP dip switch is configured for HP, this dip switch (O or B) must be set to control the appropriate reversing valve. If O is chosen, the W1/O/B terminal will energize in cooling. If B is chosen, the W1/O/B terminal will energize in heating.
Sample Wiring Diagrams with Dip Switch Positions Conventional Heating and Cooling Systems
Sample Wiring Diagrams with Dip Switch Positions Heat Pump Systems
One-Year Warranty – This Product is warranted to be free from defects in material and workmanship. If it appears within one year from the date of original installation, whether
or not actual use begins on that date, that the product does not meet this warranty, a new
or remanufactured part, at the manufacturer’s sole option to replace any defective part, will
be provided without charge for the part itself provided the defective part is returned to the distributor through a qualified servicing dealer.
THIS WARRANTY DOES NOT INCLUDE LABOR OR OTHER COSTS incurred for diagnosing, repairing, removing, installing, shipping, servicing or handling of either defective parts or replacement parts. Such costs may be covered by a separate warranty provided by the installer.
THIS WARRANTY APPLIES ONLY TO PRODUCTS IN THEIR ORIGINAL INSTALLATION LOCATION AND BECOMES VOID UPON REINSTALLATION.
LIMITATIONS OF WARRANTIES – ALL IMPLIED WARRANTIES (INCLUDING IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY) ARE HEREBY LIMITED IN DURATION TO THE PERIOD FOR WHICH THE LIMITED WARRANTY IS GIVEN. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE MAY NOT APPLY TO YOU. THE EXPRESSED WARRANTIES MADE IN THIS WARRANTY ARE EXCLUSIVE AND MAY NOT BE ALTERED, ENLARGED, OR CHANGED BY ANY DISTRIBUTOR, DEALER, OR OTHER PERSON WHATSOEVER.
ALL WORK UNDER THE TERMS OF THIS WARRANTY SHALL BE PERFORMED DURING NORMAL WORKING HOURS. ALL REPLACEMENT PARTS, WHETHER NEW OR REMANUFACTURED, ASSUME AS THEIR WARRANTY PERIOD ONLY THE REMAINING TIME PERIOD OF THIS WARRANTY.
THE MANUFACTURER WILL NOT BE RESPONSIBLE FOR:
This equipment has been tested and found to comply with the limits for an intentional radiator, pursuant to Part 15, subpart C of the FCC rules. These limits are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference in radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Notice: Only peripherals complying with FCC limits may be attached to this equipment. Operation with noncompliant peripherals or peripherals not recommended by Venstar is likely to result in interference to radio and TV reception. Changes or modifications to the product, not expressly approved by Venstar could void the user’s authority to operate the equipment.
FCC – INDOOR Mobile Radio Information:
To comply with FCC/IC RF exposure limits for general population / uncontrolled exposure, the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.
This Device complies with Industry Canada License-exempt RSS standard(s). Operation is subject to the following two conditions: 1) this device may not cause interference, and 2) this device must accept any interference, including interference that may cause undesired operation of the device.
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.
This color touchscreen has the ability to receive updates to its firmware. Periodically firmware updates are released by the manufacturer to add features and/or performance enhancements. This manual was produced reflecting the most current firmware/feature set at the time of publication, firmware rev. 4.04. Firmware releases after rev. 4.04 may not be adequately depicted in this manual. Please refer to the appropriate website or contact your place of purchase to learn about changes to the thermostat after firmware release 4.04.
Download Manual:
Venstar T8800 Touchscreen Digital Thermostat Owner Manual
other manuals:
Venstar T8800 Touchscreen Digital Thermostat Quick Setup Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…