Thank You
Congratulations and thank you for purchasing your new Venstar EXPLORER Mini® thermostat. This guide is intended to help you install and setup the basic features of your Thermostat. For a full owner’s manual and installation guide, visit venstar.com.
Venstar EXPLORER Mini® Thermostat is designed to work with 24V systems requiring both the R & C wires. This includes gas, electric, oil, forced air, variable speed, heat pump and radiant heat. It can control:
Contents
Step 1 – Power Off Current System
WARNING: Failure to follow this step can result in personal injury and/or death from shock and electrocution.
Step 2 – Remove Faceplate
Remove the faceplate of current system. Most faceplates snap-off or feature small screws that will need to be removed.
WARNING: If you see large thick electrical wires, wire nuts, or if your system is labeled 120V or 240V DO NOT PROCEED. THIS THERMOSTAT IS NOT COMPATIBLE WITH THESE SYSTEMS
WARNING: Failure to follow this step can result in personal injury and/or death from shock and electrocution.
Step 3 – Before you go any further
Determine what your existing wiring and equipment situation is before you disconnect any wires. If you are unsure of what type of system you have, you may need to seek professional support.
MAKING 4 WIRES WORK when 5 are required (without the optional Add-A-Wire accessory)
MAKING 5 WIRES WORK when 6 are required (without the optional Add-A-Wire accessory)
Step 4 – Label & Disconnect Wires
Wire from the old thermostat terminal marked | Function | Install on the new thermostat connector marked | Wire Color |
G or F | Fan | G | |
Y1, Y | Cooling | Y1 | |
W1, W | Heating | W1/0/B | |
Rh, R, M, Vr, A | Power | R | |
C | Common | C | |
O/B | Rev. Valve | W1/O/B* | |
W2 | 2nd Stage Heat | W2 | |
Y2 | 2nd Stage Cooling | Y2 | |
Ck1 | Dry Contact Switch | CK | |
CKGND | Dry Contact Switch | R |
O/B is used if your system is a Heat Pump.
Step 5 – Remove Current Backplate
Step 6 – Mount New Base
Step 7 – Connect Wires
Match your previous wire configuration to the new base. One by one, connect each wire by inserting the metal end into the corresponding slot and tightening the screw.
Step 8 – Check Dip Switch
Ensure which switch is correct for your system. Dip switches are located on the back of the thermostat
Step 9 – Attach Thermostat
Align the pins on the thermostat circuit board with the corresponding holes below the wiring connectors and push the top and the bottom of the plastic housing enclosing the display until it clicks into place, top and bottom.
Front of thermostat should click into place easily. If you encounter resistance do not apply excess force – remove check that the pins are straight and ensure there are no wires in the way and retry.
Step 10 – Switch Power/Circuit Breakers Back On
Turn your furnace and air conditioner breakers back on at your breaker panel.
Step 11 – Set Up Wi-Fi Connection
Overview
At minimum, the fi rst 3 tasks below must be completed to access your thermostat remotely from a browser. The 4th step is optional (highly recommended) and only is needed to access your thermostat(s) from
a mobile device.
These steps are:
TABLE OF BUTTON PRESSES TO ENTER MENUS
Quick Start – Connect to Wi-Fi
The EXPLORER Mini thermostats are joined to a Wi-Fi network with the help of the Venstar Configurator App. This app may be downloaded from your mobile device’s app store. Once the EXPLORER Mini thermostat is installed the Configurator App will facilitate connection to the access point in 6 steps as outlined below.
Although there is more than one way to create a Skyport account, the steps below illustrate account creation from a browser. To create a Skyport account a thermostat must be joined to the account.
If the thermostat is connected to the local Wi-Fi Access Point, but you do not have a Skyport account, you may create an account and join the thermostat to the account by doing the following:
Once you have connected to Skyport, and you have standard HVAC equipment, you should be ready to use the thermostat to control your equipment. Skyport will maintain the correct time and date on your thermostat. If you would like to set up a program/schedule to maintain the desired temperature at various times of the day, you can do this manually at the thermostat. The complete manual is available to help you on the Venstar website at: Venstar.com. It is much easier to setup the time period program/schedule on the Skyport Web App. To make these adjustments and more to your thermostat from Skyport follow these steps:
You now may select and customize the thermostat. To start from this screen; select one of the buttons on the left.
A quick summary of these buttons is as follows:
Use the following troubleshooting guide to diagnose common problems. If you are still having problems or are unsure please visit www.venstar.com/thermostats or e-mail customer service at thermostatsupport@venstar.com
Problem | Possible Cause | Solution |
The air conditioning does not attempt to turn on. | The compressor timer lockout may prevent the air conditioner from turning on for a period of time. | Adjust the Compressor Min. Off Time to “0”. |
The cooling setpoint is set too high. | Lower the cooling setpoint or lower the cooling setpoint limit. | |
The display is blank. | Lack of proper power. | Make sure the power is on to the furnace and that you have a 24 vac between R&C. |
The heating does not attempt to turn on. | The heating setpoint is set too low. | Raise the heating setpoint or raise the heating setpoint limit. |
When using a residential heat pump the heat comes on instead of the air conditioning. | The thermostat reversing valve dip switch is set incorrectly. | Set the reversing valve dip switch to the opposite position. |
When calling for air conditioning both the heat and cool come on. | The thermostat equipment dip switch is configured for “HP” and the HVAC unit is a gas/electric. | Set the equipment dip switch for “gas”. |
Problem | Possible Cause | Solution |
The thermostat won’t connect to the access point. | Wrong password. | Enter the correct password. |
Access point offline. | Bring access point online. | |
Can’t connect to Skyport | No internet connection on access point. | Restore internet. |
Firewall restrictions | Check firewall settings. | |
Can’t get a 6 digit pairing code. | Thermostat already in account. | Factory default thermostat. |
Remove from Skyport account. |
One-Year Warranty – This Product is warranted to be free from defects in material and workmanship. If it appears within one year from the date of original installation, whether or not actual use begins on that date, that the product does not meet this warranty, a new or remanufactured part, at the manufacturer’s sole option to replace any defective part, will be provided without charge for the part itself provided the defective part is returned to the distributor through a qualified servicing dealer. THIS WARRANTY DOES NOT INCLUDE LABOR OR OTHER COSTS incurred for diagnosing, repairing, removing, installing, shipping, servicing or handling of either defective parts or replacement parts. Such costs may be covered by a separate warranty provided by the installer. THIS WARRANTY APPLIES ONLYTO PRODUCTS IN THEIR ORIGINAL INSTALLATION LOCATION AND BECOMES VOID UPON REINSTALLATION.
LIMITATIONS OF WARRANTIES – ALL IMPLIED WARRANTIES (INCLUDING IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY) ARE HEREBY LIMITED IN DURATION TO THE PERIOD FOR WHICH THE LIMITED WARRANTY IS GIVEN. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SOTHE ABOVE MAY NOT APPLYTO YOU. THE EXPRESSED WARRANTIES MADE IN THIS WARRANTY ARE EXCLUSIVE AND MAY NOT BE ALTERED, ENLARGED, OR CHANGED BY ANY DISTRIBUTOR, DEALER, OR OTHER PERSON WHATSOEVER. ALL WORK UNDERTHE TERMS OF THIS WARRANTY SHALL BE PERFORMED DURING NORMAL WORKING HOURS. ALL REPLACEMENT PARTS, WHETHER NEW OR REMANUFACTURED, ASSUME ASTHEIR WARRANTY PERIOD ONLYTHE REMAINING TIME PERIOD OF THIS WARRANTY.
THE MANUFACTURER WILL NOT BE RESPONSIBLE FOR:
This warranty gives you specific legal rights and you may also have other rights which may vary from state to state. This equipment has been tested and found to comply with the limits for an intentional radiator, pursuant to Part 15, subpart C of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference in radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Notice: Only peripherals complying with FCC limits may be attached to this equipment. Operation with noncompliant peripherals or peripherals not recommended by Venstar is likely to result in interference to radio and TV reception. Changes or modifications to the product, not expressly approved by Venstar could void the user’s authority to operate the equipment.
To comply with FCC/IC RF exposure limits for general population / uncontrolled exposure, the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. This Device complies with Industry Canada License-exempt RSS standard(s). Operation is subject to the following two conditions: 1) this device may not cause interference, and 2) this device must accept any interference, including interference that may cause undesired operation of the device. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. We, Venstar, declare under our sole responsibility that the device to which this declaration relates: Complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCC ID: MUH-SKYPORT8 IC: 12547A-SKYPORT8
These numbers can be located on the inside of the thermostat backplate, in the upper right corner. Patents Issued & Pendin Printed on recycled paper. P/N 88-1234 12/17 rev. 2
Download Manual:
Venstar T2150 Programmable Thermostat Quick Start Guide
OTHER MANUALS
Venstar T2150 Programmable Thermostat Product Specifications Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…