CAUTION Follow Installation Instructions carefully. DISCONNECT POWER TO THE HEATER – AIR CONDITIONER BEFORE REMOVING THE OLD THERMOSTAT AND INSTALLING THE NEW THERMOSTAT.
CAUTION The two Alkaline “AA” batteries must be replaced at least once every 12 months to ensure proper operation. The “Low Battery” icon will appear on the thermostat display when it is time to replace the batteries. If the thermostat is connected to 24v power, the batteries should still be installed, but are not required. When “Low Battery” is displayed the batteries must be replaced immediately. The manufacturer cannot be liable for improper operation of the thermostat if the batteries are not immediately replaced. Annual battery replacement is especially critical in locations subject to freezing temperatures. The thermostat will be unable to turn on the heating system if the batteries are exhausted.
Display
FAN SWITCH On or Auto
Operation
Fahrenheit or Celsius
Operation
The batteries must be replaced immediately when the thermostat displays the Low Battery icon.
*The RC and RH terminals have a factory-installed jumper to control single transformer systems. Remove this jumper to control dual transformer systems.
4 Wire, 1 Stage Cooling, 1 Stage Heating
Residential Gas or Electric Heat, Electric Cool, split systems & package units. For the jumper, configuration see pages 18 and 19.
Common wire is optional in all installations. If a common wire is not used the thermostat must be powered by two AA alkaline batteries. These batteries must be replaced (page 10) each year or when the Low Battery indicator is displayed (page 3).
4 Wire, 1 Stage Cooling, 1 Stage Heating-Heat Pump with O reversing valve.
Residential Heat Pumps, split systems & package units, with no auxiliary heat. For the jumper, configuration sees page 20.
Common wire is optional in all installations. If a common wire is not used the thermostat must be powered by two AA alkaline batteries. These batteries must be replaced (page 10) each year or when the Low Battery indicator is displayed (page 3).
4 Wire, 1 Stage Cooling, 1 Stage Heating-Heat Pump with B reversing valve.
Residential Heat Pumps, split systems & package units, with no auxiliary heat. For the jumper, configuration sees page 21.
Common wire is optional in all installations. If a common wire is not used the thermostat must be powered by two AA alkaline batteries. These batteries must be replaced (page 10) each year or when the Low Battery indicator is displayed (page 3).
3 Wire, 1 Stage Heating
Residential Gas or Electric Heat units with a separately controlled fan. For the jumper, configuration see pages 18 and 19.
Common wire is optional in all installations. If a common wire is not used the thermostat must be powered by two AA alkaline batteries. These batteries must be replaced (page 10) each year or when the Low Battery indicator is displayed (page 3).
2 Wire, 1 Stage Gas Heat
Residential Gas or Millivolt units. For the jumper, configuration sees page 18.
Common wire is optional in all installations. If a common wire is not used the thermostat must be powered by two AA alkaline batteries. These batteries must be replaced (page 10) each year or when the Low Battery indicator is displayed (page 3).
Dual Transformer 5 Wire, 1 Stage Cooling, 1 Stage Heating
Residential Gas or Electric Heat, Electric Cool, split systems & package units. For the jumper, configuration see pages 18 and 19.
Common wire is optional in all installations. If a common wire is not used the thermostat must be powered by two AA alkaline batteries. These batteries must be replaced (page 10) each year or when the Low Battery indicator is displayed (page 3).
Cooling and Gas Heating
Residential Gas, Electric Cool, split systems & package units.
OUTPUTS | ||
No Demand | With Demand | |
Cooling Mode | O/B* | Y, G, O/B* |
Heating Mode | O/B* | W, O/B* |
*Output active depending on O/B jumper configuration – For normal operation do not connect to equipment.
Cooling and Electric Heating
Residential Electric Heat units with a separately controlled fan.
OUTPUTS | ||
No Demand | With Demand | |
Cooling Mode | O/B* | Y, G, O/B* |
Heating Mode | O/B* | W, G, O/B* |
*Output active depending on O/B jumper configuration – For normal operation do not connect to equipment.
Cooling and Heating – Heat Pump with O reversing valve.
Residential Heat Pumps, split systems & package units, with no auxiliary heat.
OUTPUTS | ||
No Demand | With Demand | |
Cooling Mode | O | Y, G, O |
Heating Mode | – | Y , G |
Y active in Heating
Cooling and Heating – Heat Pump with B reversing valve.
Residential Heat Pumps, split systems & package units, with no auxiliary heat.
Y active in Heating
One-Year Warranty – This Product is warranted to be free from defects in material and workmanship. If it appears within one year from the date of original installation, whether or not actual use begins on that date, that the product does not meet this warranty, a new or remanufactured part, at the manufacturer’s sole option to replace any defective part, will be provided without charge for the part itself provided the defective part is returned to the distributor through a qualified servicing dealer. THIS WARRANTY DOES NOT INCLUDE LABOR OR OTHER COSTS incurred for diagnosing, repairing, removing, installing, shipping, servicing or handling of either defective parts or replacement parts. Such costs may be covered by a separate warranty provided by the installer.
THIS WARRANTY APPLIES ONLY TO PRODUCTS IN THEIR ORIGINAL INSTALLATION LOCATION AND BECOMES VOID UPON REINSTALLATION. LIMITATIONS OF WARRANTIES – ALL IMPLIED WARRANTIES (INCLUDING IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY) ARE HEREBY LIMITED IN DURATION TO THE PERIOD FOR WHICH THE LIMITED WARRANTY IS GIVEN. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE MAY NOT APPLY TO YOU. THE EXPRESSED WARRANTIES MADE IN THIS WARRANTY ARE EXCLUSIVE AND MAY NOT BE ALTERED, ENLARGED, OR CHANGED BY ANY DISTRIBUTOR, DEALER, OR OTHER PERSON WHATSOEVER. ALL WORK UNDER THE TERMS OF THIS WARRANTY SHALL BE PERFORMED DURING NORMAL WORKING HOURS. ALL REPLACEMENT PARTS, WHETHER NEW OR REMANUFACTURED, ASSUME AS THEIR WARRANTY PERIOD ONLY THE REMAINING TIME PERIOD OF THIS WARRANTY. THE MANUFACTURER WILL NOT BE RESPONSIBLE FOR:
This warranty gives you specific legal rights and you may also have other rights which may vary from state to state.
Download Manual:
Venstar T0130 Programmable Thermostat Owner Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…