Uheat

Uheat T6100 WiFi Programmable Thermostat Installation Instruction

Uheat T6100 WiFi Programmable Thermostat

INTRODUCTION

The T6100 series is an intuitive programmable thermostat used to control an electrical floor heating systems or water heating systems. It will keep the home at a comfortable temp whilst minimizing energy use. Install the app on your smart phone to control heating system remotely with the WiFi thermostat.

TECHNICAL SPECIFICATIONS

  • Supply voltage: 85-265Vac 50/60Hz
  • Standby power: <1W
  • Max load: 16A(electric heating)/3A(water heating)
  • IP class: IP21
  • Cable specification: ≤2.5mm²

INSTALLATION

  • Loosen fixing screw located in the bottom of the thermostat to get the front panel
  • Connect the thermostat according to the Wiring Instruction.

  • Align top part of front panel and back panel to fit these two parts. Then fix them with screw.
  • Insert the back panel into wall box with provided screws.

WIRING INSTRUCTION

THERMOSTAT SYMBOLS

WIFI CONNECTION

  • Step 1: Scan the QR code or download the Warmme from the APP store/Google browser.
  • Step 2: Register and log in with your mobile number/ email address in the APP.
  • Step 3: Click “Create a family” to enter family information and click “Done”.
  • Step 4: Click “Add Device” or “+” on the top-right to add a device.
  • Step 5: Click “Wifi thermostat”, and follow-ups to operate the thermostat, when the WIFI icon flashes quickly, please click “Press to connect”.
  • Step 6: Enter Wifi password, and click “Confirm
  • Step 7: If the device is added successfully, you can change the device name and set region, then, click “Done”.
  • Attention: If failed, please confirm the Wifi is 2.4G version and check the Wifi signals, then, use the “AP mode” in the top right to connect again.
  • Step 8: You can check the real-time temperature and set temperature etc. at the control interface.

FUNCTION AND OPERATION

On/Off

  • Press to turn On/Off.
  • Note: When frost protection is active, the thermostat will maintain the frost protection temp when it is Off.

Temporary Override Temperature

  • The temporary override temp is only valid at the current event and it will not be saved.
  • On the actual temp interface, press to set temporary override temp.
  • Press to confirm and back to the actual temp interface

Key-Lock

  • Lock all keys to prevent the settings from being changed. On the actual temp interface, press and hold for 3 seconds to lock or unlock all the keys.

Set the Time

  • On the actual temp interface, press then the will flash.
  • Press to enter day setng.
  • Press to set day.
  • Press to enter hour settng.
  • Press to set hour.
  • Press to enter minute settng.
  • Press to set minute.
  • Press to confirm and back to the day settng interface.
  • Press twice to back to the actual temp interface.

Holiday Mode

  • In Holiday Mode, the thermostat will maintain the set temp until the holiday time ends.
  • On the actual temp interface, press then the will flash.
  • Press to select.
  • Press to enter the holiday days setting.
  • Press to set holiday days.
  • Press to enter the temp setting.
  • Press to set temp.
  • Press to confirm and back to the actual temp interface

Hold Mode

  • In Hold Mode, The thermostat will hold the set temp until you cancel this mode.
  • On the actual temp interface, press then the will flash.
  • Press to select.
  • Press to enter Hold ON/OFF setng.
  • Press to set Hold ON.
  • Press to enter temp setting.
  • Press to set temp.
  • Press to confirm and back to the actual temp interface.

Edit Setting

  • Edit Settings can set and change the parameters.
  • If you don’t choose Holiday Mode or Hold Mode.
  • The thermostat runs according to the parameters of Edit.
  • On the actual temp interface, press then the will flash.
  • Press to select.
  • Press to enter day selection of Edit Settings.
  • Press to select a day.
  • Press to enter the event selection of the day.
  • Press to select an event.
  • Press to select the event’s starting time.
  • Press to set the hour of starting time.
  • Press to enter the minute setting
  • Press to set the minute of starting time.
  • Press to enter the temp setting.
  • Press to set the temp.
  • Press to confirm and back to the event selection of the day.

Default parameters.

Advanced Setting

The thermostat provides advanced settings to suit various special situations. These are normally set by
technicians during initial installation.
On the actual temp interface, press then the will flash.
Press to select.
Press to enter the advanced setting.
Each setting can be accessed by pressing and parameters adjusted by pressing

  • Room temp calibration: Calibrate the temp detected by room sensor.
  • Floor temp calibration: Calibrate the temp detected by floor sensor.
  • Anti-frozen function: This option allows you to bring warmth to your plant and pet with a lower temp. displays when you turn off the thermostat.
  • In hydronic heating system, it will keep away from freezing.
  • Sensor selection:
    • Room sensor: Run by room sensor.
    • Floor sensor: Run by floor sensor.
    • Both sensors: Run by room sensor with floor temp limit.
  • Floor temp limit: If you choose both sensors, the floor temp limit must be set to protect floor.
  • Temp unit: °C and °F can be selected.
  • Output delay: This option help you avoid inadvertent operation on heating.
  • Temp deviation: The deviation is 1°C. The thermostat starts to work when the actual temp is 1°C lower than set temp and stops to work when the actual temp is 1°C higher than set temp.
  • Reverse output: This function works for the cooling system. When the temp is 1°C higher than set temp, the thermostat will disconnect the cooling system. otherwise, it will connect the cooling system.
  • Schedule: Select a weekly schedule for the Edit. There are 2 options:
    • 7: each day from Mon to Sun can be set individually.
    • 5+1+1: 5 days from Mon to Fri have the same events, Sat and Sun can be set individually.
  • Adaptive function: After several days of installation and use, the Adaptive function ensures that the required temp has already been reached when the next event begins.
  • Reset: All parameters are restored to default values

Open window detection
This function only works when room sensor or both sensors is selected. The thermostat with this function will shut off automatically for 15 min when the window opens, as it can detect that the room temp plummets

DIMENSION

TROUBLESHOOTING

  • E1: Room sensor error.
  • E2: Floor sensor error.

Reference:

DOWNLOAD MANUALS:

Uheat T6100 WiFi Programmable Thermostat Installation Instruction

Uheat T6100 WiFi Programmable Thermostat Installation Instruction

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

1 year ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

1 year ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

1 year ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

1 year ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

1 year ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

1 year ago